Desa (V)T32EN SERIES, (V)T32EP SERIES Location of Termination Cap, Combustible Noncombustible

Page 7

Location of Termination Cap

D

E V

B L

 

C

 

 

Fixed

V

 

Closed

 

 

F

Openable

 

V

 

B

B

B

Openable ClosedFixed

H

VI

B

V J XG

AM

N N

 

G

 

V

 

G

V K X

V

 

 

 

 

 

 

 

 

 

 

 

A

 

 

V TERMINATION CAP

X AIR SUPPLY INLET

 

G

GAS METER

 

 

RESTRICTED AREA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(TERMINATION PROHIBITED)

A

=

clearance above grade, veranda, porch, deck, or

I

=

clearance to service regulator vent outlet [*72" (182.9 cm)

 

 

balcony [*12" (30.5 cm) minimum]

 

 

 

minimum]

 

 

B

=

clearance to window or door that may be opened

J

=

clearance to non-mechanical air supply inlet to building

 

 

[6" (15 cm) min. for 10,000 Btu or less; 9" (23 cm) in US

 

 

or the combustion air inlet to any other fireplace

 

 

if between 10,000 and 50,000, 12" (30 cm) in Canada

 

 

[6" (15 cm) min. for 10,000 Btu or less; 9" (23 cm) in US

 

 

if between 10,000 and 100,000; 12" (30 cm) in US if

 

 

if between 10,000 and 50,000, 12" (30 cm) in Canada

 

 

greater than 50,000, 36" (91 cm) in Canada if greater

 

 

if between 10,000 and 100,000; 12" (30 cm) in US if

 

 

than 100,000]

 

 

 

greater than 50,000, 36" (91 cm) in Canada if greater

C

=

clearance to permanently closed window

 

 

 

than 100,000]

 

 

 

 

[minimum 12" (30.5 cm) recommended to prevent

K

=

clearance to a mechanical air supply inlet [*In Canada,

 

 

condensation on window]

 

 

 

6 ft. (1.83m) minimum; In US 3 ft. (91 cm) above if within

D

=

vertical clearance to ventilated soffit located above the

 

 

10 ft. (3 m) horizontally]

 

 

 

 

terminal within a horizontal distance of 24" (61 cm) from L

=

† clearance above paved side-walk or a paved driveway

 

 

the center-line of the terminal [18" (45.7 cm) minimum]

 

 

located on public property [*84" (213.3 cm) minimum]

E

=

clearance to unventilated soffit [12" (30.5 cm) minimum] M =

clearance under veranda, porch, deck

F

=

clearance to outside corner (see below)

 

 

 

[*12" (30.5 cm) minimum ‡]

G

=

clearance to inside corner (see below)

 

N =

clearance above a roof shall extend a minimum of

H

=

*not to be installed above a meter/regulator assembly

 

 

24" (61 cm) above the highest point when it passes

 

 

within 36" (91.4 cm) horizontally from the center line

 

 

through the roof surface and any other obstruction within

 

 

of the regulator

 

 

 

a horizontal distance of 18" (45.7 cm)

vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings*

only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor* * as specified in CAN/CSA B149 (.1 or .2) Installation Codes (1991) for Canada and U.S.A.

Note: Local codes or regulations may require different clearances

Termination Clearances for Buildings with Combustible and Noncombustible Exteriors

Inside Corner

Outside Corner

Recessed Location

A

V

A = 6" (15.2 cm)

V

B = 6" (15.2 cm)

B

 

D

C

C

E

V

Balcony with No Side Wall

G

V

Balcony with Perpendicular Side Wall

H

V

J

Combustible &

Noncombustible

C = Maximum depth of 48" (121.9 cm) for recessed location

D = Minimum width for back wall of recessed location - Combustible - 38" (965 mm) Noncombustible - 24" (61 cm)

E = Clearance from corner in recessed location- Combustible - 6" (15.2 cm)

Figure 7 - Minimum Clearances for Termination Cap

111987-01Dwww.desatech.com

Image 7
Contents What to do if YOU Smell GAS Safety Information Table of ContentsSafety Information High traffic areas Product FeaturesLocal Codes Product IdentificationLocation and space requirements Pre-Installation PreparationProper clearances must be maintained Venting clearances ClearancesFraming and finishing Front Top of Standoffs Vent See ventingCombustible Noncombustible Location of Termination CapInstallation Precautions Venting Installation InstructionsInstallation Planning Installing Horizontal Vent Cap Noncombustible Exterior Ground Floor Installation Recommended Applications Corner ground floor installation Snorkel Termination InstallationHorizontal System Installation Using TWO 90 Elbows Flat Ceiling Installation Installation for vertical terminationConnect a section of pipe and extend up through the hole Twist-lock the vent cap onto the last section of vent pipe Installing FirestopVertical Venting High Altitude InstallationNumber Description Parts list for venting kits and componentsCheck GAS Type Fireplace InstallationInstalling optional blower accessories Model BK InstallationPlug in blower power cord to duplex outlet Model BKT InstallationBlower Wiring Diagram Installing Gas Piping to Fireplace LocationInstallation Items Needed Checking GAS Connections Connecting Fireplace to GAS SupplyTest Pressures Equal To or Less Than Psig 3.5 kPa Pressure Testing Fireplace Gas ConnectionsRemoving Glass Door Cleaning Glass DoorRemoving/Replacing Glass Door Removing Louver PanelsInstalling logs, lava rock and glowing embers Installing Optional Brick liner Model BL32DClose top and bottom louvers Installing Log No Wall Switch Installation Optional Remote control Installation model WRCOpen lower louver panel of firebox Pilot Gas Wiring DiagramLine Operating Fireplace For your safety Read before lightingLighting Instructions Burner Flame Pattern Inspecting BurnersTo Turn OFF GAS To Appliance Optional Remote OperationLogs Cleaning MaintenanceGlass Door Pilot and burnersVenting system Cleaning and MaintenanceTroubleshooting Observed Problem Possible Cause RemedyGas leak. See Warning Glass soots Flame impingement on logs Tery power is low RemoteImproper log placement Clean out air holes at burnerIllustrated Parts Breakdown Parts List 109 11102 Specifications Replacement PartsService Hints Technical ServiceAccessories Keep this Warranty Warranty InformationLimited Warranty DIRECT-VENT Fireplace