Page 23

FIREPLACE INSTALLATION

Continued

FIREPLACE INSTALLATION

23

Installing Logs, Lava Rock and Glowing Embers

OPERATING FIREPLACE

 

For Your Safety Read Before Lighting

 

 

 

INSTALLING LOGS, LAVA ROCK AND GLOWING EMBERS

Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with fireplace.

Open louvers, remove screen, unlock door latches, and open glass door. See Removing/Replacing Glass Door, steps 1 and 2 on page 22. Install logs according to instructions for fireplace model numbers.

5

6

7

1.Place log #1 (left base log) onto pin on left side of burner as shown in Figure 44.

2.Place log #2 (right base log) onto pin on right side of burner as shown in Figure 44.

3.Place logs #3 (left front log) and log #4 (right front log) onto pins as shown in Figure 45.

4.Place log #5 (right rear log) onto pins on right rear of burner (see Figure 46). Rest log #6 (middle crossover log) on top of log number 2 as shown in Figure 46.

5.Place back end of log #7 (left rear log) onto pin on left rear burner and rest front onto log #1 as shown in Figure 47.

6.Rest log #8 (left crossover log) onto log #3 and rest log #9 (right crossover log) onto logs #4 and #5 as shown in Figure 48.

7.Pull ember material apart into pieces no larger than a dime. Place these pieces loosely and sparingly directly onto the exposed front section of the burner (see Figure 49). This will create the glowing ember appearance as the flame touches the ember material. Do not block air slots by using too much ember material in one area. It is not necessary to use all of the ember material provided.

NOTICE: Do not put lava rock on burner or under burner. Placing lava rock on burner will cause perfor- mance problems.

8.Close glass door, lock door latches, replace screen, and close louvers (see Removing/Replacing Glass Door, steps 5 through 7 on page 22).

WARNING: The glass door must be securely in place before running this fireplace. Do not run this fireplace if glass is missing or broken.

2

3

1

4

 

Figure 44

- Installing Logs

Figure 45 - Installing Logs

No. 1 and No. 2

No. 3 and No. 4

Figure 46 - Installing Logs

Figure 47 - Installing Log No. 7

No. 5 and No. 6

 

9

8

Figure 48 - Installing Logs No. 8 and No. 9

Ember Material

Figure 49 - Placing Ember Material on Burner

OPERATING FIREPLACE

FOR YOUR SAFETY READ

BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

For morevisit www..com

111923-01B

Image 23
Contents For Your Safety What to do if YOU Smell GAS OWNER’S Operation Installation ManualFor Your Safety Safety Information Table of ContentsLocal Codes Product IdentificationLocation and Space Requirements Product FeaturesPRE-INSTALLATION Preparation Framing and Finishing ClearancesBalcony with Perpendicular Side Wall Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Horizontal Vent Cap Noncombustible Exterior Ground Floor Installation Horizontal Termination ConfigurationsCorner Installation Venting with Two 90 Elbows Horizontal System Installation Using TWO ElbowsFlat Ceiling Installation Installation for Vertical TerminationVenting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting High Altitude InstallationCheck GAS Type Fireplace InstallationInstalling Optional Blower Accessories Model BK InstallationAttaching Speed Control to Firebox Model BKT InstallationInstallation Items Needed Installing GAS Piping to Fireplace LocationBlower Wiring Diagram Checking GAS Connections Connecting Fireplace to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Installing Optional Wall Mount Switch GWMS2Removing Louver Panels Installing Remote ReceiverREMOVING/REPLACING Glass Door Removing Glass Doors Installing Brick Liner Models BL36DASA and BL36DHASACleaning Glass Door Operating Fireplace Installing LOGS, Lava Rock and Glowing EmbersFor Your Safety Read Before Lighting Optional HAND-HELD Remote Operation Manual Lighting ProcedureLighting Instructions To Turn OFF GAS To ApplianceON/OFF Series Model Ghrcb Manual ModeAuto Thermostatic Mode Safety FeaturesOperating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning and MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementSpecifications Replacement PartsService Hints Technical ServiceModels Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListBurner Assembly for Models VK36N, VK36NH, VK36P, VK36PH Parts List Accessories Owners Registration Form Postage Required 111923-01B Warranty Information

(V)K36P SERIES, (V)K36N SERIES specifications

Desa (V)K36P Series and (V)K36N Series represent a significant advancement in the world of high-efficiency heating solutions, known for their innovative features and technologies that cater to varying heating needs. These series are engineered for both residential and commercial applications, offering flexibility and efficiency to meet diverse climate requirements.

One of the standout features of the Desa (V)K36P and (V)K36N Series is their advanced combustion technology. Utilizing a unique burner design, these units maximize energy output while minimizing emissions. This is particularly important in today's environmentally-conscious market, where efficient energy use and reduced carbon footprints are critical.

Moreover, these series incorporate advanced heat exchanger technologies that ensure optimal thermal efficiency. This design minimizes heat loss and enhances the performance of the heating system, allowing users to enjoy comfortable indoor temperatures without excessive energy costs. The durable materials used in the construction of these heat exchangers also contribute to their longevity and reliability, making them a worthy investment.

Another notable characteristic of the Desa (V)K36P and (V)K36N Series is their user-friendly control systems. Features such as digital thermostats and programmable settings allow users to customize their heating schedules with ease, ensuring their living or working spaces remain comfortable at all times. Additionally, some models come equipped with Wi-Fi connectivity, enabling remote operation and monitoring via smartphone applications.

In terms of safety, the Desa series does not compromise. Each unit includes multiple safety features, such as overheat protection, flame failure detection, and pressure relief systems, ensuring that users can rely on their heaters with peace of mind.

Installation and maintenance are also made simpler with the Desa (V)K36P and (V)K36N Series. These models are designed for straightforward installation, minimizing disruptions during setup. They also require minimal maintenance, which reduces long-term service costs for users.

In conclusion, the Desa (V)K36P and (V)K36N Series stand out in the market due to their innovative technologies, high efficiency, user-friendly controls, and robust safety measures. These qualities make them excellent choices for anyone seeking reliable and effective heating solutions in a variety of settings.