Desa (V)K36P SERIES ON/OFF Series Model Ghrcb, Thermostat Series Model Ghrctb, Manual Mode

Page 25

OPERATING FIREPLACE

Continued

IMPORTANT: Do not leave the selector switch in the RE- MOTE or ON position when the pilot is not lit. This will drain the battery.

OPERATING FIREPLACE

25

Optional Hand-Held Remote Operation (Cont.)

 

 

2.

Press AUTO button to select this mode.

3.

Set the desired room temperature by pressing the TEMP

 

+ or - buttons.

Blower Control Knob

(Optional Accessory)

OFF

ON

Selector Switch

 

 

ON OFF REMOTE

 

 

 

 

 

in Remote

 

 

 

 

 

Position

 

 

 

 

 

 

 

 

 

 

Variable

Control Knob

N

 

L

 

O

 

I

 

 

O

T

F

O

H

O

 

 

F

 

 

LIP

 

 

 

 

 

 

 

Gas Control Knob in ON Position

4. Press the POWER and LOCK buttons together to turn off

the fireplace

Note: Do not leave the hand-held remote in the AUTO mode close to the fireplace. The radiant heat from the fireplace will turn off the fireplace. Ideally, place the hand-held remote in the center of the room facing towards the fireplace.

Note: Do not hold the hand-held remote for a long time. Body temperature will affect its operation in the AUTO mode.

Figure 51 - Setting the Selector Switch, Gas Control Knob, and Variable Control Knob for Remote Operation

ON/OFF SERIES MODEL GHRCB

Hold the control button on the hand-held remote until burner turns on. Hold the control button again until burner turns off (see Figure 52).

TO LOCK press both buttons on hand-held remote control until light stops flashing. Hand-held remote control is now locked. If the fire is on it will be turned off automatically. In the locked state, the light will not light up when any button is pressed.

TO UNLOCK press both buttons together on hand-held remote control until the light stops flashing. The hand-held remote is now unlocked.

Control Button

Turns Burners

On and Off

Figure 52 - On/Off Hand-Held Remote Control Unit GHRCB

THERMOSTAT SERIES MODEL GHRCTB

The hand-held remote can be operated using either the manual mode (MANU) or thermostatic mode (AUTO) (see Figure 53). To select Fahrenheit/Centigrade mode display, carefully press the ˚C/ ˚F mode button with the end of a paper clip or similar blunt object.

Manual Mode

1.Press the POWER and LOCK buttons together to turn on the hand-held remote control.

2.Press the MANU button to turn on the fireplace.

3.Press the POWER and LOCK buttons together to turn off the fireplace.

Auto (Thermostatic) Mode

1.Press the POWER and LOCK buttons together to turn on the hand-held remote control.

Digital Display

Shows

Temperature and

Settings

Turns Burners

On or Off

Decreases Room

Temperature in

AUTO Mode

Turns Hand-Held Remote On or Off and Allows You to Choose the Manual Setting

Selects Auto Setting

Increases Room

Temperature in AUTO

Mode

Locks System to Prevent Accidental Ignition

Figure 53 - Thermostat Hand-Held Remote Control Unit GHRCTB

Safety Features

When away from home for an extended period of time or as a child safety feature to prevent accidental ignition of the fire- place, the receiver ON/OFF/REMOTE switch should be in the OFF position.

Auto Shutoff Feature

1.If the average room temperature exceeds 82 degrees Fahr- enheit (28 degrees Centigrade), the hand-held remote con- trol will perform a safety override and shut the fireplace off. This feature is not available in the MANU mode.

2.The receiver continuously receives signals from the hand- held remote to control the room temperature. If the hand- held remote is misplaced, obstructed, or for any reason cannot transmit to the receiver, the receiver will shut off the fireplace after 8 minutes.

Key Pad Lock Feature

This feature allows the user to lock/unlock the keypad on the hand-held remote in the MANU or AUTO mode to prevent inadvertent operation (i.e. children operating the hand-held re- mote control, etc.). The keypad is locked in either on or off. Press the POWER and LOCK buttons together to turn the unit on or off.

For morevisit www..com

111923-01B

Image 25
Contents For Your Safety OWNER’S Operation Installation ManualFor Your Safety What to do if YOU Smell GAS Safety Information Table of ContentsLocal Codes Product IdentificationPRE-INSTALLATION Preparation Product FeaturesLocation and Space Requirements Framing and Finishing ClearancesBalcony with Perpendicular Side Wall Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Horizontal Vent Cap Noncombustible Exterior Ground Floor Installation Horizontal Termination ConfigurationsCorner Installation Venting with Two 90 Elbows Horizontal System Installation Using TWO ElbowsFlat Ceiling Installation Installation for Vertical TerminationVenting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting High Altitude InstallationInstalling Optional Blower Accessories Fireplace InstallationModel BK Installation Check GAS TypeAttaching Speed Control to Firebox Model BKT InstallationBlower Wiring Diagram Installing GAS Piping to Fireplace LocationInstallation Items Needed Installation Items Needed Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Installing Optional Wall Mount Switch GWMS2REMOVING/REPLACING Glass Door Installing Remote ReceiverRemoving Louver Panels Cleaning Glass Door Installing Brick Liner Models BL36DASA and BL36DHASARemoving Glass Doors For Your Safety Read Before Lighting Installing LOGS, Lava Rock and Glowing EmbersOperating Fireplace Lighting Instructions Manual Lighting ProcedureTo Turn OFF GAS To Appliance Optional HAND-HELD Remote OperationAuto Thermostatic Mode Manual ModeSafety Features ON/OFF Series Model GhrcbPilot Assembly Operating Optional Blower AccessoryInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatGlass Door Cleaning and MaintenancePilot and Burners LogsObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementService Hints Replacement PartsTechnical Service SpecificationsModels Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListBurner Assembly for Models VK36N, VK36NH, VK36P, VK36PH Parts List Accessories Owners Registration Form Postage Required 111923-01B Warranty Information

(V)K36P SERIES, (V)K36N SERIES specifications

Desa (V)K36P Series and (V)K36N Series represent a significant advancement in the world of high-efficiency heating solutions, known for their innovative features and technologies that cater to varying heating needs. These series are engineered for both residential and commercial applications, offering flexibility and efficiency to meet diverse climate requirements.

One of the standout features of the Desa (V)K36P and (V)K36N Series is their advanced combustion technology. Utilizing a unique burner design, these units maximize energy output while minimizing emissions. This is particularly important in today's environmentally-conscious market, where efficient energy use and reduced carbon footprints are critical.

Moreover, these series incorporate advanced heat exchanger technologies that ensure optimal thermal efficiency. This design minimizes heat loss and enhances the performance of the heating system, allowing users to enjoy comfortable indoor temperatures without excessive energy costs. The durable materials used in the construction of these heat exchangers also contribute to their longevity and reliability, making them a worthy investment.

Another notable characteristic of the Desa (V)K36P and (V)K36N Series is their user-friendly control systems. Features such as digital thermostats and programmable settings allow users to customize their heating schedules with ease, ensuring their living or working spaces remain comfortable at all times. Additionally, some models come equipped with Wi-Fi connectivity, enabling remote operation and monitoring via smartphone applications.

In terms of safety, the Desa series does not compromise. Each unit includes multiple safety features, such as overheat protection, flame failure detection, and pressure relief systems, ensuring that users can rely on their heaters with peace of mind.

Installation and maintenance are also made simpler with the Desa (V)K36P and (V)K36N Series. These models are designed for straightforward installation, minimizing disruptions during setup. They also require minimal maintenance, which reduces long-term service costs for users.

In conclusion, the Desa (V)K36P and (V)K36N Series stand out in the market due to their innovative technologies, high efficiency, user-friendly controls, and robust safety measures. These qualities make them excellent choices for anyone seeking reliable and effective heating solutions in a variety of settings.