Desa (V)K36P SERIES, (V)K36N SERIES installation manual Parts List

Page 35

PARTS LIST

Models (V)K36N, (V)K36NH, (V)K36P, (V)K36PH

35

PARTS LIST

BURNER ASSEMBLY FOR MODELS (V)K36N, (V)K36NH, (V)K36P, (V)K36PH

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 31 of this manual.

KEY

PART

 

 

NO.

NUMBER

DESCRIPTION

QTY.

 

 

 

 

1

111957-01

Pan Assembly Burner

1

2

111311-01

Grate Base

1

3

111313-01

Burner Base Bottom

1

4

26808

Valve Bracket

1

5

11107

Screw, #10-32 x 1/4 PPH Zinc

4

6

111310-01

Firebox Bottom

1

7

11102

Screw, #8-32 x 3/8 PPH Zinc

2

8

111912-01

Tubing Assembly

1

9

111288-02

Flex Gas Line

1

10

108084-02

Pilot Assembly (Natural Gas)

1

 

108084-03

Pilot Assembly (Propane/LP Gas)

1

11

14389

Hi-Lo Natural Gas Valve

1

 

14390

Hi-Lo Propane/LP Gas Valve

1

12

11165

Screw, #10 x 5/8 HWH Zinc

22

13

111913-02

Burner Base Gasket

1

14

14500

Brass Fitting

1

15

111316-01

Pilot Bracket

1

16

104506-23

Burner Orifice (Natural Gas)

1

 

104506-17

Burner Orifice (Propane/LP Gas)

1

17

26827

Switch Bracket

1

 

 

 

 

For morevisit www..com

111923-01B

Image 35
Contents For Your Safety What to do if YOU Smell GAS OWNER’S Operation Installation ManualFor Your Safety Safety Information Table of ContentsLocal Codes Product IdentificationLocation and Space Requirements Product FeaturesPRE-INSTALLATION Preparation Framing and Finishing ClearancesBalcony with Perpendicular Side Wall Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Horizontal Vent Cap Noncombustible Exterior Ground Floor Installation Horizontal Termination ConfigurationsCorner Installation Venting with Two 90 Elbows Horizontal System Installation Using TWO ElbowsFlat Ceiling Installation Installation for Vertical TerminationVenting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting High Altitude InstallationCheck GAS Type Fireplace InstallationInstalling Optional Blower Accessories Model BK InstallationAttaching Speed Control to Firebox Model BKT InstallationInstallation Items Needed Installing GAS Piping to Fireplace LocationBlower Wiring Diagram Checking GAS Connections Connecting Fireplace to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Installing Optional Wall Mount Switch GWMS2Removing Louver Panels Installing Remote ReceiverREMOVING/REPLACING Glass Door Removing Glass Doors Installing Brick Liner Models BL36DASA and BL36DHASACleaning Glass Door Operating Fireplace Installing LOGS, Lava Rock and Glowing EmbersFor Your Safety Read Before Lighting Optional HAND-HELD Remote Operation Manual Lighting ProcedureLighting Instructions To Turn OFF GAS To ApplianceON/OFF Series Model Ghrcb Manual ModeAuto Thermostatic Mode Safety FeaturesOperating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning and MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementSpecifications Replacement PartsService Hints Technical ServiceModels Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListBurner Assembly for Models VK36N, VK36NH, VK36P, VK36PH Parts List Accessories Owners Registration Form Postage Required 111923-01B Warranty Information

(V)K36P SERIES, (V)K36N SERIES specifications

Desa (V)K36P Series and (V)K36N Series represent a significant advancement in the world of high-efficiency heating solutions, known for their innovative features and technologies that cater to varying heating needs. These series are engineered for both residential and commercial applications, offering flexibility and efficiency to meet diverse climate requirements.

One of the standout features of the Desa (V)K36P and (V)K36N Series is their advanced combustion technology. Utilizing a unique burner design, these units maximize energy output while minimizing emissions. This is particularly important in today's environmentally-conscious market, where efficient energy use and reduced carbon footprints are critical.

Moreover, these series incorporate advanced heat exchanger technologies that ensure optimal thermal efficiency. This design minimizes heat loss and enhances the performance of the heating system, allowing users to enjoy comfortable indoor temperatures without excessive energy costs. The durable materials used in the construction of these heat exchangers also contribute to their longevity and reliability, making them a worthy investment.

Another notable characteristic of the Desa (V)K36P and (V)K36N Series is their user-friendly control systems. Features such as digital thermostats and programmable settings allow users to customize their heating schedules with ease, ensuring their living or working spaces remain comfortable at all times. Additionally, some models come equipped with Wi-Fi connectivity, enabling remote operation and monitoring via smartphone applications.

In terms of safety, the Desa series does not compromise. Each unit includes multiple safety features, such as overheat protection, flame failure detection, and pressure relief systems, ensuring that users can rely on their heaters with peace of mind.

Installation and maintenance are also made simpler with the Desa (V)K36P and (V)K36N Series. These models are designed for straightforward installation, minimizing disruptions during setup. They also require minimal maintenance, which reduces long-term service costs for users.

In conclusion, the Desa (V)K36P and (V)K36N Series stand out in the market due to their innovative technologies, high efficiency, user-friendly controls, and robust safety measures. These qualities make them excellent choices for anyone seeking reliable and effective heating solutions in a variety of settings.