Desa PHK-18, PHK-24, PHK-30 Checking GAS Connections, Hearth KIT Assembly and Installation

Page 6

6

INSTALLATION

Checking Gas Connections

Hearth Kit Assembly and Installation

INSTALLATION

Continued

CHECKING GAS CONNECTIONS

WARNING: Test all gas piping and connections, internal and external to unit, for leaks after installing or servicing. Correct all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1.Disconnect log set and its individual equipment shutoff valve from gas supply piping system.

2.Cap off open end of gas pipe where equipment shutoff valve was connected.

3.Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter.

4.Check all joints of gas supply piping system. Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Reconnect log set and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Figure 5).

2.Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter.

3.Check all joints from gas meter to equipment shutoff valve (see Figure 5). Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Equipment Shutoff

Valve

Gas Meter

Figure 5 - Checking Gas Joints

HEARTH KIT ASSEMBLY AND INSTALLATION

Kit Assembly - Ramp Pan Burner

1.Determine which side the gas line feeds into the fireplace. This logset is factory set up for right side (facing) gas feed. If your gas line is on the right side, go to the Installation and Gas Connection section below. If your gas line is on the left side of the fireplace, proceed with steps 2 through 4 below.

2.Remove the nuts securing the gas inlet venturi to the bottom of the burner. (see Figure 6).

3.Remove the venturi from the pan taking care not to damage the gasket between the venturi and the pan.

4.Reverse the direction of the venturi and re-attach to the bottom of the pan using factory nuts.

Installation and Gas Connection

1.Place the ramp burner assembly in the center of the fireplace floor. Make sure the front of pan faces forward.

2.Thread the gas supply fitting to the fireplace gas supply pipe. Use thread sealant.

3.Install the gas connector tube to the gas supply fitting. Carefully shape tube to attach to adapter fitting. Be careful not to cause kinks in tube.

4.Attach opposite end of gas connector tube to the gas inlet fitting on the end of the venturi.

Burner Inlet Fitting

(Factory Installed)

Burner Orifi ce (Factory Installed)

Adapter

Fitting

Gas Connector

Tube

Burner Inlet Venturi (Attached to Pan Bottom)

Figure 7 - Connecting Gas to Appliance

For more information, visit www.desatech.com

115425-01

Image 6
Contents RGA 2-72 Approved What to do if YOU Smell GASTable of Contents Local Codes Safety InformationProduct Identification UnpackingVenting Specifications for Installation InstallationFlue Opening Specifications Check GAS TypeInstalling Damper Clamp Connecting to GAS SupplyHearth KIT Assembly and Installation Checking GAS ConnectionsTesting Burner for Leaks Adding PAN MaterialTechnical Service Cleaning MaintenanceReplacement Parts Operating ApplianceService Hints TroubleshootingObserved Problem Possible Cause Remedy Accessories Equipment Shutoff Valve GA5010Illustrated Parts Breakdown Parts List PHK/BCSOwners Registration Form Postage Required Warranty Information Keep this Warranty

BCS18, BCS24, BCS30, PHK-18, PHK-24, PHK-30 specifications

Desa PHK-18, PHK-24, PHK-30, BCS18, BCS24, and BCS30 are advanced heating systems designed to meet diverse application needs in both residential and commercial environments. These models represent the forefront of efficiency and temperature control technology.

The Desa PHK series consists of three distinct models: PHK-18, PHK-24, and PHK-30. These are high-efficiency gas heaters known for their reliability and performance. The numbers indicate their heating capacity, with PHK-18 suitable for smaller spaces, while PHK-30 is capable of heating larger areas. These units incorporate an innovative combustion technology that minimizes emissions while maximizing heat output.

One of the standout features of the PHK series is their digital thermostat, allowing users precise control over the heating settings. This not only enhances comfort but also contributes to energy savings. Additionally, these heaters come equipped with an automatic shut-off function and safety features that comply with industry standards, ensuring peace of mind during operation.

On the other hand, the BCS series, which includes BCS18, BCS24, and BCS30 models, focuses more on versatile heating options. These units utilize both gas and electricity to provide a dual-fuel heating capability. This flexibility allows users to select the most economical source of energy depending on availability and cost. The BCS series also features a sleek design, making them an attractive addition to any space.

Advanced technology is at the core of these systems, with optional Wi-Fi connectivity enabling users to manage their heating remotely via smartphone apps. This feature allows for scheduling and real-time adjustments, ensuring that spaces are always at the desired temperature when needed.

Both the PHK and BCS series are built with durability in mind. They utilize high-quality materials and are constructed to withstand the rigors of daily use. Regular maintenance is made easy with accessible parts for cleaning and replacement.

In summary, the Desa PHK-18, PHK-24, PHK-30, BCS18, BCS24, and BCS30 represent the next generation of heating solutions, combining efficiency, advanced technology, and user-friendly features. They cater to a broad spectrum of heating requirements, making them ideal for a wide range of applications. Whether for home comfort or industrial needs, these models ensure optimal performance and satisfaction.