Installation Procedures

2. INSTALLING DRAIN HOSE

Select whether the drain hose will be connected

Wrap the insulation (drain hose) around the drain

to the left or right side.(Fig.3) Insert the drain hose into the drain pan, then secure the drain hose with a nylon fastener. (Fig.6)

(Fig. 6)

Drain pan

Nylon fastener

Drain hose

hose connection. (Fig.7)

(Fig. 7)

Drain pan

Drain hose

Insulation (Drain hose)

Be sure to arrange the drain hose correctly so that it is leveled lower than the drain hose connecting port of the indoor unit.

Fig. 8

OK

NO

NO

Arrange the drain hose

Drain hose

lower than this portion.

 

CAUTION

Do not install the unit drain hose side is too high. Height A should be less than 5 mm.(Fig.9)

Fig. 9

Drain hose

A A

B. UNDER CEILING TYPE

Using the installation template, drill holes for piping and anchor bolts(for holes).(Fig.10)

900mm

Installation

Drilling position for anchor bolt

200mmtemplate

Ceilling

Fig. 10

Wall

Drilling position for piping

10

Page 12
Image 12
Haier AC182ACEAA, AC142ACERA, AC142ACEAA Installing Drain Hose, Under Ceiling Type, Drain pan Nylon fastener Drain hose