1. DRILLING FOR PIPING

Manual background Installation Procedures

1. DRILLING FOR PIPING

Select piping and drain directions. (Fig.11)

Rear (Install the drain hose in the direction.)

Right

Fig. 11

CAUTION

Install the drain hose at the rear; it should not be installed on the top or right side.

When the directions are selected, drill 80mm and 50mm or 150mm dia. hole on the wall so that the hole is tilted downward toward the outdoor for smooth water flow.

Fig. 12

Wall

 

 

6mm

2.DRILLING HOLES FOR ANCHOR BOLTS AND INSTALLING THE ANCHOR BOLTS

With a concrete drill, drill four 12.7 mm dia. Holes. (Fig.13)

Fig. 13

60 to 70mm

12.7mm

Insert the anchor bolts into the drilled holes, and drive the pins completely into the anchor bolts with a hammer. (Fig. 14)

3. INSTALLING BRACKETS

Install the brackets with nuts, washers and spring washers.(Fig. 15)

Fig. 15

Spring washer

 

Special nut

Bracket

 

Bracket (Left)

Bracket (Right)

4. INSTALLING INDOOR UNIT Reset the hex bolts as shown in Fig.16.

Fig. 16

Hex bolt

Indoor unit Manual background 8 to 13mm

Apply the indoor unit to the brackets.(Fig.17)

Fig. 17

Bolt Bracket

Indoor unit

Now, securely tighten the hex bolts in both sides.