Desa 103426-01 INSTALLING LOGS Split Oak Design Models, Installation, Continued

Page 13
INSTALLING LOGS (Split Oak Design Models)

SPLIT OAK AND AMERICAN OAK DESIGN 18", 24" AND 30" MODELS

INSTALLATION

Continued

INSTALLING LOGS (Split Oak Design Models)

Figure 22 - Installing Bottom Middle LogWARNING: Failure to posi- tion the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal in- jury.

Peg

Bottom Middle Log (#2)

 

 

Hole

 

Peg

Groove

Peg

Metal Post

 

Top Middle Log (#4)

Hole

Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.Place front logs (#1L and #1R) on top of the grate. Make sure the notches in the bottom of the logs fit over the grate prongs (see Figure 21, page 12). Push back of logs flush with metal grate bar. Note: 18" model has only one front log.

2.Rest bottom middle log (#2) behind metal posts on front burner. Make sure the grooves in the bottom of the log fit over the grate. Bring the log forward next to the metal posts. The pegs on the log must be on top (see Figure 22).

3.Slide the grooves in the back of the rear log (#3) against the rear grate prongs. Make sure the peg on the log is on top (see Figure 23).

4.Place the top middle log (#4) on the bottom middle log (#2). Make sure the pegs of the bottom middle log fit se- curely in the holes of the top middle log (see Figure 24).

5.Place the crossover log (#5) on the back log and the top middle log. Make sure the peg on the rear log is in the hole in the bottom of the crossover log. The crossover log should fit in the cutout of the top middle log (see Figure 25).

Groove

 

 

Peg

 

 

 

 

Bottom

Metal Post

 

 

 

Grate

 

 

Middle

 

 

 

 

Log

Figure 22 - Installing Bottom Middle Log

Figure 24 - Installing Top Log (#4)

 

 

 

(#2)

 

 

 

 

Groove in

 

 

 

Crossover

Peg

 

 

Log (#4)

Back of Log

Rear Log (#3)

 

 

 

 

 

 

 

Hole

Grate

 

 

Cutout

 

Prong

 

 

 

 

 

 

 

Rear

 

 

 

Peg

 

 

 

 

Burner

Groove

 

 

 

in Back

 

 

 

of Log

 

 

 

 

Grate

 

 

 

 

Prong

 

 

 

Figure 23 - Installing Rear Log (#3)
Figure 25 - Installing Crossover Log (#5)

103426

13

Image 13
Contents where not prohibited by state or local codes OWNER’S OPERATION AND INSTALLATION MANUALDESA INTERNATIONAL —WHAT TO DO IF YOU SMELL GASUNVENTED NATURAL GAS LOG HEATER SAFETY INFORMATIONWARNINGS Safety Device PRODUCT FEATURESPRODUCT IDENTIFICATION LOCAL CODESPROVIDING ADEQUATE VENTILATION AIR FOR COMBUSTION AND VENTILATIONDETERMINING AIR FLOW FOR HEATER LOCATION Unusually Tight ConstructionVENTILATION AIR ContinuedVentilation Air From Inside Building Ventilation Air From OutdoorsINSTALLATION AND CLEARANCES INSTALLATIONIf Not Using Mantel CHECK GAS TYPEMantel Clearances If Using MantelDetermining Minimum Mantel Clearance INSTALLATIONINSTALLATION Floor ClearancesUNVENTED NATURAL GAS LOG HEATER ContinuedInstallation Items Needed INSTALLING HEATER BASE ASSEMBLYINSTALLATION ContinuedINSTALLATION CONNECTING TO GAS SUPPLYInstallation Items Needed UNVENTED NATURAL GAS LOG HEATERPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemCHECKING GAS CONNECTIONS Test Pressures In Excess Of 1/2 PSIGINSTALLATION INSTALLING LOGS American Oak Design ModelsUNVENTED NATURAL GAS LOG HEATER ContinuedINSTALLATION INSTALLING LOGS Split Oak Design ModelsFigure 22 - Installing Bottom Middle Log Figure 24 - Installing Top Log #4OPERATING HEATER Thermostat-ControlledModels FOR YOUR SAFETYREAD BEFORE LIGHTING LIGHTING INSTRUCTIONSManually-ControlledModels FOR YOUR SAFETY MANUAL LIGHTING PROCEDUREThermostat Controlled Models TO TURN OFF GAS TO APPLIANCEManually-ControlledModels INSPECTING BURNERSVARIABLE CONTROL OPERATION PILOT FLAME PATTERNFRONT BURNER FLAME PATTERN CLEANING AND MAINTENANCEODS/PILOT AND BURNERS LOGSOBSERVED PROBLEM TROUBLESHOOTINGPOSSIBLE CAUSE REMEDYOBSERVED PROBLEM TROUBLESHOOTINGMaintenance, page ContinuedOBSERVED PROBLEM TROUBLESHOOTINGMaintenance, page UNVENTED NATURAL GAS LOG HEATERFor Masonry and Factory- built Metal Fireplace OPTIONAL POSITIONING OF THERMOSTAT SENSING BULBREPLACEMENT PARTS SPECIFICATIONSSERVICE HINTS TECHNICAL SERVICEMANUAL SHUTOFF VALVE - GA5010 ACCESSORIESBLACK FIREPLACE HOOD - GA6050 BRASS FIREPLACE HOOD - GA6052Variable Manually Controlled Models VS18NVB ILLUSTRATED PARTS BREAKDOWN4CFS18NVB VS24NVB CFS24NVB VS30NVB CFS30NVB UNVENTED NATURAL GAS LOG HEATERVariable Manually-ControlledSplit Oak Models PARTS LISTPART NUMBER FOR VS18NVB/CFS18NVBUNVENTED NATURAL GAS LOG HEATER ILLUSTRATED PARTS BREAKDOWNPARTS LIST Thermostat-ControlledSplit Oak ModelsPART NUMBER FOR VS18NTAVariable Manually-Controlled Models VL18NV VL24NV ILLUSTRATED PARTS3 BREAKDOWNVL30NV UNVENTED NATURAL GAS LOG HEATERPARTS LIST Variable Manually-ControlledAmerican Oak ModelsPART NUMBER FOR VL18NVUNVENTED NATURAL GAS LOG HEATER Page WARRANTY INFORMATION LIMITED WARRANTY VENT-FREENATURAL GAS LOG HEATERSNOT A UPC