Desa VC42N, CGCDV42NR, VC42P, CGCDV42PR Removing/Replacing Glass Door, Removing Louver Panels

Page 25

Fireplace

Installation

Continued

Installing 9-Volt Alkaline Battery in Hand-

Held Remote Control Unit

1. Remove battery cover on back of remote control unit.

2. Attach terminal wires to a 9-volt alkaline battery (not included). Place battery into the battery housing.

3. Replace battery cover onto remote control unit.

Removing Louver Panels

Remove the top and bottom louver panels by si- multaneously pulling both top end spring latches towards the center of the appliance until they are disengaged from the locating holes (see Figure 40). Repeat for bottom spring latches and pull the lou- vers outward. To install or replace items removed, simply reverse the procedures above.

Battery Cover

Remote Control Unit

 

Louver Panel

Spring Latch

Terminal

 

Wires

 

9-Volt

Battery

Housing

Battery

 

Figure 39 - Installing Battery in Hand-

Held Remote Control Unit

Removing/Replacing Glass

Door

CAUTION: Do not operate this fireplace with a broken glass door panel or without the glass door panel securely in place. For replacement part informa- tion see Replacement Parts, page 37.

CAUTION: Wear gloves and safety glasses while handling or removing broken glass. Do not remove if glass is hot. Keep children and pets away from glass.

WARNING: If fireplace has been running, turn off and un- plug fireplace. Let cool before re- moving glass door or louvers.

Figure 40 - Removing Louver Panel

Removing Glass Door

If replacement of glass is necessary, the entire assembly, glass and frame, must be replaced. If glass is broken, wear gloves and tape the remaining fragments onto the frame.

1.Remove screen assembly by pushing the rod either left or right and then down and forward to remove screen/rod assembly from the fire- box. Set assembly aside.

2.Lift up on latches to unlock. There are two on top of firebox and two below firebox that hold glass door in place (see Figure 41).

3.While holding glass door to prevent it from falling and causing injury, remove the five screws from the hinge located on the left side of door frame assembly (see Figure 41).

Unlock Lock

Latch

Screw

Hinge

Glass Frame

Assembly

Figure 41 - Removing/Replacing Glass

Door

116236-01E

www.desatech.com

25

Image 25
Contents What to do if YOU Smell GAS Table of Contents Safety Information High traffic areas Product IdentificationPre-Installation Preparation Product FeaturesLocal Codes Location and space requirements42 1067 mm ClearancesFront 36 914 mm Top of Standoffs Vent See venting Venting clearancesNoncombustible mantels at any height above Framing and finishingFireplace Termination CAP AIR Supply Inlet GAS Meter Location of Termination CapInstallation Precautions Venting Installation InstructionsInstallation Planning Installing Horizontal Vent Cap Noncombustible Exterior Round Termination Ground Floor InstallationRecommended Applications Corner ground floor installation Snorkel Termination InstallationHorizontal System Installation Using TWO 90 Elbows Flat Ceiling Installation Installation for vertical terminationConnect a section of pipe and extend up through the hole Twist-lock the vent cap onto the last section of vent pipe Vertical Venting High Altitude InstallationDesa 5/8 Pipe & Vent Kits Number Description Parts list for venting kits and componentsInstalling optional blower accessories Fireplace InstallationModel BK Installation Plug in blower power cordBlower Model BKT Model BKT InstallationBlower Wiring Diagram Installing Gas Piping to Fireplace LocationInstallation Items Needed Propane/LP Supply TankExternal Regulator Vent Pointing Down Connecting Fireplace to GAS SupplyTest Pressures Equal To or Less Than Psig 3.5 kPa Checking GAS ConnectionsClose equipment shutoff valve see Figure Disconnect fireplace and its individual equipPressure Testing Fireplace Gas Connections Installing optional wall Mount Switch gwmS2Installing Remote Receiver Turn off fireplace see To Turn Off Gas to Ap- pliance,Removing Louver Panels Removing/Replacing Glass DoorRemoving Glass Door Installing Brick liner Models BL42DASA and BL42DHASA Installing lava rock and glowing embersCleaning Glass Door Operating Fireplace For your safety Read before lightingLighting Instructions Close top and bottom louversTo Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Hand-Held Remote OperationThermostat Series Model HRC200 On/Off Series Model HRC100Pilot assembly Operating optional blower accessoryKey Pad Lock Feature Inspecting BurnersBurner Flame Pattern Cleaning MaintenanceGlass Door Logs Pilot and burnersVenting system Observed Problem Possible Cause Remedy TroubleshootingBurner orifice clogged Clean burner see Cleaning Is lit Problem could be caused byAfter pilot lights, keep gas Long enough Control knob pressedOr shut off Service person Remote does not function When burner is lit HI position when burner isTery power is low Cold Minute Air in gas line Operate burner until air isStatement above Service Hints Replacement PartsTechnical Service SpecificationsModels VC42N, VVC42N, VC42P, VVC42P, cgcDV42nr and cgcDV42pr Illustrated Parts BreakdownParts List 19 18 Burner Pan Assembly Accessories Wall mounted thermostat control kit gwmt1 Not Shown Wall mounted on/off switch gwmS2 Not ShownKeep this Warranty Warranty InformationLimited Warranty DIRECT-VENT Fireplace

(V)VC42P, CGCDV42PR, VC42N, CGCDV42NR, VC42P, CGCDV42PR specifications

Desa (V)VC42P, CGCDV42PR, VC42N, CGCDV42NR, VC42P, and CGCDV42PR are a range of sophisticated heating solutions that exemplify modern design and efficiency. Designed for residential comfort, these models offer advanced features and technologies that set them apart in the market.

One of the most notable characteristics of these units is their innovative heating technology. They utilize advanced vented and vent-free systems, allowing for flexible installation options based on the needs of the home. These systems efficiently convert fuel into heat, ensuring a high level of warmth with minimal energy consumption. The models cater to various fuel types, including natural gas and propane, allowing consumers to choose the most economical option for their heating needs.

The Desa models are engineered with user-friendly controls, featuring modern thermostats that provide precise temperature regulation. This allows for enhanced comfort and energy efficiency, as users can program the units to operate only when needed. Many of the models come equipped with remote control functionality, offering added convenience for adjusting settings from the comfort of one's sofa.

In terms of safety, these heaters are built with robust safety features such as automatic shut-off systems and oxygen depletion sensors, ensuring that air quality remains safe and that the units operate without risk. This attention to safety is crucial for consumer peace of mind, particularly in homes with children or pets.

Aesthetically, the Desa models shine with an attractive design that complements various interior styles. They are available in multiple finishes and sizes, allowing homeowners to choose a heater that best fits their space and decor. Whether placed in a living room, bedroom, or hallway, these heaters not only provide warmth but also add to the overall ambiance of the home.

Durability is another key characteristic of the Desa series. Constructed with high-quality materials, these heaters promise longevity and reliability. They are designed to withstand the rigors of daily use while maintaining efficiency and effectiveness.

In conclusion, the Desa (V)VC42P, CGCDV42PR, VC42N, CGCDV42NR, VC42P, and CGCDV42PR offer a comprehensive heating solution that combines efficiency, safety, design, and technology. Ideal for modern households, these units represent a smart choice for anyone looking to enhance their home’s comfort and warmth.