Desa (V)VC42P, CGCDV42PR Location of Termination Cap, Termination CAP AIR Supply Inlet GAS Meter

Page 8

Location of Termination Cap

D

E V

B L

 

C

 

 

Fixed

V

 

Closed

 

 

F

Openable

 

V

 

 

B

 

B

Openable

B

Fixed

Closed

H

V

B

I

V J XG

AM

NN

 

G

 

V

 

G

V K X

V

V TERMINATION CAP

X AIR SUPPLY INLET

G

GAS METER

A

RESTRICTED AREA (TERMINATION PROHIBITED)

A= clearance above grade, veranda, porch, deck, or balcony [*12 inches (30.5mc) minimum]

B= clearance to window or door that may be opened

[12 inches (30.5cm) minimum]

C = clearance to permanently closed window [minimum 12 inches (30.5cm) recommended to prevent condensation on window]

D = vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 24 inches (61cm) from the center-line of the terminal [18 inches (45.7cm) minimum]

E= clearance to unventilated soffit [12 inches (30.5cm) minimum]

F= clearance to outside corner (see below)

G= clearance to inside corner (see below)

H= *not to be installed above a meter/regulator assembly within

36 inches (91.4cm) horizontally from the center-line of the regulator

I= clearance to service regulator vent outlet [*72 inches (182.9cm) minimum]

J= clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other fireplace [*12 inches (30.5cm) minimum]

K= clearance to a mechanical air supply inlet [*72 inches (182.9cm) minimum]

L= † clearance above paved side-walk or a paved driveway located on public property [*84 inches (213.3cm) minimum]

M= clearance under veranda, porch, deck [*12 inches (30.5cm) minimum ‡]

N= clearance above a roof shall extend a minimum of 24 inches (61cm) above the highest point when it passes through the roof surface and any other obstruction within a horizontal distance of 18 inches (45.7cm)

† vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings*

only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor* * as specified in CAN/CSA B149 (.1 or .2) Installation Codes (1991) for Canada and U.S.A.

Note: Local codes or regulations may require different clearances

Termination Clearances for Buildings with Combustible and Noncombustible Exteriors

Inside Corner

A

V

Outside Corner

Recessed Location

 

 

D

 

 

C

C

A = 6" (15.2cm)

 

E

 

 

V

V

 

B

B = 6" (15.2cm)

 

Balcony with No Side Wall

G

V

G = 12" (30.5cm) minimum clearance

Balcony with Perpendicular Side Wall

H

V

J

Combustible &

Noncombustible

H = 24" (61cm)

J = 20" (50.8cm)

C = Maximum depth of 48" (121.9cm) for recessed location

D = Minimum width for back wall of recessed location - Combustible - 38" (965mm) Noncombustible - 24" (61cm)

E = Clearance from corner in recessed location- Combustible - 6" (15.2cm) Noncombustible - 2" (5.1cm)

Figure 7 - Minimum Clearances for Termination Cap

www.desatech.com116236-01E

Image 8
Contents What to do if YOU Smell GAS Table of Contents Safety Information Product Identification High traffic areasProduct Features Pre-Installation PreparationLocal Codes Location and space requirementsClearances 42 1067 mmFront 36 914 mm Top of Standoffs Vent See venting Venting clearancesFireplace Framing and finishingNoncombustible mantels at any height above Location of Termination Cap Termination CAP AIR Supply Inlet GAS MeterVenting Installation Instructions Installation PrecautionsInstallation Planning Installing Horizontal Vent Cap Noncombustible Exterior Ground Floor Installation Round TerminationSnorkel Termination Installation Recommended Applications Corner ground floor installationHorizontal System Installation Using TWO 90 Elbows Connect a section of pipe and extend up through the hole Installation for vertical terminationFlat Ceiling Installation Twist-lock the vent cap onto the last section of vent pipe High Altitude Installation Vertical VentingParts list for venting kits and components Desa 5/8 Pipe & Vent Kits Number DescriptionFireplace Installation Installing optional blower accessoriesModel BK Installation Plug in blower power cordModel BKT Installation Blower Model BKTInstallation Items Needed Installing Gas Piping to Fireplace LocationBlower Wiring Diagram Connecting Fireplace to GAS Supply Propane/LP Supply TankExternal Regulator Vent Pointing DownChecking GAS Connections Test Pressures Equal To or Less Than Psig 3.5 kPaClose equipment shutoff valve see Figure Disconnect fireplace and its individual equipInstalling optional wall Mount Switch gwmS2 Pressure Testing Fireplace Gas ConnectionsInstalling Remote Receiver Turn off fireplace see To Turn Off Gas to Ap- pliance,Removing Glass Door Removing/Replacing Glass DoorRemoving Louver Panels Cleaning Glass Door Installing lava rock and glowing embersInstalling Brick liner Models BL42DASA and BL42DHASA For your safety Read before lighting Operating FireplaceLighting Instructions Close top and bottom louversManual Lighting Procedure To Turn OFF GAS To ApplianceOptional Hand-Held Remote OperationOn/Off Series Model HRC100 Thermostat Series Model HRC200Operating optional blower accessory Pilot assemblyKey Pad Lock Feature Inspecting BurnersGlass Door Cleaning MaintenanceBurner Flame Pattern Venting system Pilot and burnersLogs Troubleshooting Observed Problem Possible Cause RemedyProblem could be caused by Burner orifice clogged Clean burner see Cleaning Is litAfter pilot lights, keep gas Long enough Control knob pressedWhen burner is lit HI position when burner is Or shut off Service person Remote does not functionTery power is low Cold Minute Air in gas line Operate burner until air isStatement above Replacement Parts Service HintsTechnical Service SpecificationsIllustrated Parts Breakdown Models VC42N, VVC42N, VC42P, VVC42P, cgcDV42nr and cgcDV42prParts List 19 18 Burner Pan Assembly Accessories Wall mounted on/off switch gwmS2 Not Shown Wall mounted thermostat control kit gwmt1 Not ShownLimited Warranty DIRECT-VENT Fireplace Warranty InformationKeep this Warranty

(V)VC42P, CGCDV42PR, VC42N, CGCDV42NR, VC42P, CGCDV42PR specifications

Desa (V)VC42P, CGCDV42PR, VC42N, CGCDV42NR, VC42P, and CGCDV42PR are a range of sophisticated heating solutions that exemplify modern design and efficiency. Designed for residential comfort, these models offer advanced features and technologies that set them apart in the market.

One of the most notable characteristics of these units is their innovative heating technology. They utilize advanced vented and vent-free systems, allowing for flexible installation options based on the needs of the home. These systems efficiently convert fuel into heat, ensuring a high level of warmth with minimal energy consumption. The models cater to various fuel types, including natural gas and propane, allowing consumers to choose the most economical option for their heating needs.

The Desa models are engineered with user-friendly controls, featuring modern thermostats that provide precise temperature regulation. This allows for enhanced comfort and energy efficiency, as users can program the units to operate only when needed. Many of the models come equipped with remote control functionality, offering added convenience for adjusting settings from the comfort of one's sofa.

In terms of safety, these heaters are built with robust safety features such as automatic shut-off systems and oxygen depletion sensors, ensuring that air quality remains safe and that the units operate without risk. This attention to safety is crucial for consumer peace of mind, particularly in homes with children or pets.

Aesthetically, the Desa models shine with an attractive design that complements various interior styles. They are available in multiple finishes and sizes, allowing homeowners to choose a heater that best fits their space and decor. Whether placed in a living room, bedroom, or hallway, these heaters not only provide warmth but also add to the overall ambiance of the home.

Durability is another key characteristic of the Desa series. Constructed with high-quality materials, these heaters promise longevity and reliability. They are designed to withstand the rigors of daily use while maintaining efficiency and effectiveness.

In conclusion, the Desa (V)VC42P, CGCDV42PR, VC42N, CGCDV42NR, VC42P, and CGCDV42PR offer a comprehensive heating solution that combines efficiency, safety, design, and technology. Ideal for modern households, these units represent a smart choice for anyone looking to enhance their home’s comfort and warmth.