Install and use fireplace with care. Follow all local codes. In the absence to local codes, use the cur- rent National Fuel Gas Code ANSI Z223.1/NFPA 54* (USA) or the current CSA-B149.1 Installation Code (Canada).

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Product Features

These are a few facts that can help you understand and enjoy your direct-vent fireplace:

The venting system may be routed to the out- side of your home in several ways. It may vent through the roof (vertical) or it may vent to an outside/exterior wall (horizontal). The vent pipe installation is very important to allow for proper operation. You must follow the venting instructions very carefully for either vertical or horizontal applications.

This fireplace may be installed in any room of your house provided all local codes and these installation instructions are followed.

This fireplace requires a wall switch, hand-held remote or wall thermostat (millivolt) for opera- tion (see Accessories, page 42).

This fireplace does not require electricity to operate.

Only the blower requires electricity if installed and if you plan to install the blower at a later date, do not forget to wire the outlet at the bot- tom of the fireplace when framing.

A piezo ignitor and ceramic electrode create spark to ignite the pilot light. It does not require any matches, batteries or any other sources of ignition to light the pilot.

Each time you turn on your fireplace, you may notice some amount of condensation on the in- side of the fireplace glass. This is normal and will disappear after 10-20 minutes of operation.

Your direct-vent gas fireplace system (fireplace and venting) is a balanced and sealed gas op- erating unit. It requires approximately 10-20 minutes of operating time before the flame pattern stabilizes.

Fireplaces with the suffix of -HA have been designed to operate at altitudes of 4000 feet and above.

Pre-Installation

Preparation

Location and space requirements

Determine the safest and most efficient location for your DESA direct-vent fireplace. Make sure that rafters and wall studs are not in the way of the venting system. Choose a location where the heat output is not affected by drafts, air conditioning ducts, windows or doors. Figure 2 shows some common locations. Be aware of all restrictions and precautions before deciding the exact location for your fireplace and termination cap.

When deciding the location of your fireplace, follow these rules:

Do not connect this fireplace venting to a chim- ney flue serving a separate solid-fuel burning fireplace or appliance.

Due to high temperatures, do not locate this fireplace in high traffic areas, windy or drafty areas or near furniture or draperies.

Proper clearances must be maintained.

If your fireplace is to be installed directly on carpeting, vinyl tile or any combustible mate- rial other than wood, it must be installed on a metal or wood panel extending the full width and depth of the fireplace. See Figure 3.

Flush with a wall

Through exterior wall enclosed in a chase

Corner installation

Figure 2 - Common Fireplace Locations

36 1/4"

23 1/4"

48"

Figure 3 - Fireplace Bottom Dimensions

116236-01Ewww.desatech.com

Image 5
Contents What to do if YOU Smell GAS Table of Contents Safety Information High traffic areas Product IdentificationPre-Installation Preparation Product FeaturesLocal Codes Location and space requirements42 1067 mm ClearancesFront 36 914 mm Top of Standoffs Vent See venting Venting clearancesFireplace Framing and finishingNoncombustible mantels at any height above Termination CAP AIR Supply Inlet GAS Meter Location of Termination CapInstallation Precautions Venting Installation InstructionsInstallation Planning Installing Horizontal Vent Cap Noncombustible Exterior Round Termination Ground Floor InstallationRecommended Applications Corner ground floor installation Snorkel Termination InstallationHorizontal System Installation Using TWO 90 Elbows Connect a section of pipe and extend up through the hole Installation for vertical terminationFlat Ceiling Installation Twist-lock the vent cap onto the last section of vent pipe Vertical Venting High Altitude InstallationDesa 5/8 Pipe & Vent Kits Number Description Parts list for venting kits and componentsInstalling optional blower accessories Fireplace InstallationModel BK Installation Plug in blower power cordBlower Model BKT Model BKT InstallationInstallation Items Needed Installing Gas Piping to Fireplace LocationBlower Wiring Diagram Propane/LP Supply TankExternal Regulator Vent Pointing Down Connecting Fireplace to GAS SupplyTest Pressures Equal To or Less Than Psig 3.5 kPa Checking GAS ConnectionsClose equipment shutoff valve see Figure Disconnect fireplace and its individual equipPressure Testing Fireplace Gas Connections Installing optional wall Mount Switch gwmS2Installing Remote Receiver Turn off fireplace see To Turn Off Gas to Ap- pliance,Removing Glass Door Removing/Replacing Glass DoorRemoving Louver Panels Cleaning Glass Door Installing lava rock and glowing embersInstalling Brick liner Models BL42DASA and BL42DHASA Operating Fireplace For your safety Read before lightingLighting Instructions Close top and bottom louversTo Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Hand-Held Remote OperationThermostat Series Model HRC200 On/Off Series Model HRC100Pilot assembly Operating optional blower accessoryKey Pad Lock Feature Inspecting BurnersGlass Door Cleaning MaintenanceBurner Flame Pattern Venting system Pilot and burnersLogs Observed Problem Possible Cause Remedy TroubleshootingBurner orifice clogged Clean burner see Cleaning Is lit Problem could be caused byAfter pilot lights, keep gas Long enough Control knob pressedOr shut off Service person Remote does not function When burner is lit HI position when burner isTery power is low Cold Minute Air in gas line Operate burner until air isStatement above Service Hints Replacement PartsTechnical Service SpecificationsModels VC42N, VVC42N, VC42P, VVC42P, cgcDV42nr and cgcDV42pr Illustrated Parts BreakdownParts List 19 18 Burner Pan Assembly Accessories Wall mounted thermostat control kit gwmt1 Not Shown Wall mounted on/off switch gwmS2 Not ShownLimited Warranty DIRECT-VENT Fireplace Warranty InformationKeep this Warranty

(V)VC42P, CGCDV42PR, VC42N, CGCDV42NR, VC42P, CGCDV42PR specifications

Desa (V)VC42P, CGCDV42PR, VC42N, CGCDV42NR, VC42P, and CGCDV42PR are a range of sophisticated heating solutions that exemplify modern design and efficiency. Designed for residential comfort, these models offer advanced features and technologies that set them apart in the market.

One of the most notable characteristics of these units is their innovative heating technology. They utilize advanced vented and vent-free systems, allowing for flexible installation options based on the needs of the home. These systems efficiently convert fuel into heat, ensuring a high level of warmth with minimal energy consumption. The models cater to various fuel types, including natural gas and propane, allowing consumers to choose the most economical option for their heating needs.

The Desa models are engineered with user-friendly controls, featuring modern thermostats that provide precise temperature regulation. This allows for enhanced comfort and energy efficiency, as users can program the units to operate only when needed. Many of the models come equipped with remote control functionality, offering added convenience for adjusting settings from the comfort of one's sofa.

In terms of safety, these heaters are built with robust safety features such as automatic shut-off systems and oxygen depletion sensors, ensuring that air quality remains safe and that the units operate without risk. This attention to safety is crucial for consumer peace of mind, particularly in homes with children or pets.

Aesthetically, the Desa models shine with an attractive design that complements various interior styles. They are available in multiple finishes and sizes, allowing homeowners to choose a heater that best fits their space and decor. Whether placed in a living room, bedroom, or hallway, these heaters not only provide warmth but also add to the overall ambiance of the home.

Durability is another key characteristic of the Desa series. Constructed with high-quality materials, these heaters promise longevity and reliability. They are designed to withstand the rigors of daily use while maintaining efficiency and effectiveness.

In conclusion, the Desa (V)VC42P, CGCDV42PR, VC42N, CGCDV42NR, VC42P, and CGCDV42PR offer a comprehensive heating solution that combines efficiency, safety, design, and technology. Ideal for modern households, these units represent a smart choice for anyone looking to enhance their home’s comfort and warmth.