Desa (V)VC42P, CGCDV42PR installation manual Clearances, 42 1067 mm, Venting clearances

Page 6

Pre-Installation

Preparation

Continued

Your fireplace is designed to be used in zero clearance installations. Wall or framing material can be placed directly against any exterior sur- face on the back, sides or top of your fireplace, except where standoff spacers are integrally attached. If standoff spacers are attached to your fireplace, these spacers can be placed directly against wall or framing material. See framing details on page 7.

If you plan on installing a television or enter- tainment center recessed above your fireplace, it is recommended that you maintain a minimum 18" above top of louver opening.

When locating termination cap, it is important to observe the minimum clearances shown in Figure 7, page 8.

If recessing into a wall, you can avoid extra framing by positioning your fireplace against an already existing framing member.

Do not recess termination cap into a wall or siding.

You may paint the termination cap with 450ºF (232ºC) heat-resistant paint to coordinate with the exterior finish.

There must not be any obstruction such as bushes, garden sheds, fences, decks or util- ity buildings within 24" from the front of the termination cap.

Do not locate termination cap where excessive snow or ice build up may occur. Be sure to clear vent termination area after snow falls to prevent accidental blockage of venting system. When using snow blowers, do not direct snow towards vent termination area.

Clearances

Minimum clearances to combustibles for the fire-

place are as follows:

 

*Back and sides

0"/mm

Perpendicular walls

6" (152 mm)

Floor

0"/mm

Ceiling to louver opening

42" (1067 mm)

Front

36" (914 mm)

Top of Standoffs

0"/mm

Vent

(See venting

 

instructions for specific

 

venting clearances.)

Combustible material with a maximum thick- ness of 5/8" may be flush with the top front of fireplace.

*For back and sides of fireplace, do not pack with insulation or other materials. Zero inch clearance to combustible materials are for fram- ing purpose only.

NOTICE: This fireplace is in- tended for use as supplemental heat. Use this fireplace along with your primary heating sys- tem. Do not install this fireplace as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using fireplace. This will help circulate the heat throughout the house. In the event of a power outage, you can use this fireplace as a heat source.

www.desatech.com116236-01E

Image 6
Contents What to do if YOU Smell GAS Table of Contents Safety Information Product Identification High traffic areasLocal Codes Product FeaturesPre-Installation Preparation Location and space requirementsFront 36 914 mm Top of Standoffs Vent See venting Clearances42 1067 mm Venting clearancesFraming and finishing Noncombustible mantels at any height aboveFireplace Location of Termination Cap Termination CAP AIR Supply Inlet GAS MeterVenting Installation Instructions Installation PrecautionsInstallation Planning Installing Horizontal Vent Cap Noncombustible Exterior Ground Floor Installation Round TerminationSnorkel Termination Installation Recommended Applications Corner ground floor installationHorizontal System Installation Using TWO 90 Elbows Installation for vertical termination Flat Ceiling InstallationConnect a section of pipe and extend up through the hole Twist-lock the vent cap onto the last section of vent pipe High Altitude Installation Vertical VentingParts list for venting kits and components Desa 5/8 Pipe & Vent Kits Number DescriptionModel BK Installation Fireplace InstallationInstalling optional blower accessories Plug in blower power cordModel BKT Installation Blower Model BKTInstalling Gas Piping to Fireplace Location Blower Wiring DiagramInstallation Items Needed Connecting Fireplace to GAS Supply Propane/LP Supply TankExternal Regulator Vent Pointing DownClose equipment shutoff valve see Figure Checking GAS ConnectionsTest Pressures Equal To or Less Than Psig 3.5 kPa Disconnect fireplace and its individual equipInstalling Remote Receiver Installing optional wall Mount Switch gwmS2Pressure Testing Fireplace Gas Connections Turn off fireplace see To Turn Off Gas to Ap- pliance,Removing/Replacing Glass Door Removing Louver PanelsRemoving Glass Door Installing lava rock and glowing embers Installing Brick liner Models BL42DASA and BL42DHASACleaning Glass Door Lighting Instructions For your safety Read before lightingOperating Fireplace Close top and bottom louversOptional Hand-Held Manual Lighting ProcedureTo Turn OFF GAS To Appliance Remote OperationOn/Off Series Model HRC100 Thermostat Series Model HRC200Key Pad Lock Feature Operating optional blower accessoryPilot assembly Inspecting BurnersCleaning Maintenance Burner Flame PatternGlass Door Pilot and burners LogsVenting system Troubleshooting Observed Problem Possible Cause RemedyAfter pilot lights, keep gas Problem could be caused byBurner orifice clogged Clean burner see Cleaning Is lit Long enough Control knob pressedTery power is low When burner is lit HI position when burner isOr shut off Service person Remote does not function Cold Minute Air in gas line Operate burner until air isStatement above Technical Service Replacement PartsService Hints SpecificationsIllustrated Parts Breakdown Models VC42N, VVC42N, VC42P, VVC42P, cgcDV42nr and cgcDV42prParts List 19 18 Burner Pan Assembly Accessories Wall mounted on/off switch gwmS2 Not Shown Wall mounted thermostat control kit gwmt1 Not ShownWarranty Information Keep this WarrantyLimited Warranty DIRECT-VENT Fireplace

(V)VC42P, CGCDV42PR, VC42N, CGCDV42NR, VC42P, CGCDV42PR specifications

Desa (V)VC42P, CGCDV42PR, VC42N, CGCDV42NR, VC42P, and CGCDV42PR are a range of sophisticated heating solutions that exemplify modern design and efficiency. Designed for residential comfort, these models offer advanced features and technologies that set them apart in the market.

One of the most notable characteristics of these units is their innovative heating technology. They utilize advanced vented and vent-free systems, allowing for flexible installation options based on the needs of the home. These systems efficiently convert fuel into heat, ensuring a high level of warmth with minimal energy consumption. The models cater to various fuel types, including natural gas and propane, allowing consumers to choose the most economical option for their heating needs.

The Desa models are engineered with user-friendly controls, featuring modern thermostats that provide precise temperature regulation. This allows for enhanced comfort and energy efficiency, as users can program the units to operate only when needed. Many of the models come equipped with remote control functionality, offering added convenience for adjusting settings from the comfort of one's sofa.

In terms of safety, these heaters are built with robust safety features such as automatic shut-off systems and oxygen depletion sensors, ensuring that air quality remains safe and that the units operate without risk. This attention to safety is crucial for consumer peace of mind, particularly in homes with children or pets.

Aesthetically, the Desa models shine with an attractive design that complements various interior styles. They are available in multiple finishes and sizes, allowing homeowners to choose a heater that best fits their space and decor. Whether placed in a living room, bedroom, or hallway, these heaters not only provide warmth but also add to the overall ambiance of the home.

Durability is another key characteristic of the Desa series. Constructed with high-quality materials, these heaters promise longevity and reliability. They are designed to withstand the rigors of daily use while maintaining efficiency and effectiveness.

In conclusion, the Desa (V)VC42P, CGCDV42PR, VC42N, CGCDV42NR, VC42P, and CGCDV42PR offer a comprehensive heating solution that combines efficiency, safety, design, and technology. Ideal for modern households, these units represent a smart choice for anyone looking to enhance their home’s comfort and warmth.