Desa VC42N, CGCDV42NR, VC42P, CGCDV42PR, (V)VC42P, CGCDV42PR installation manual Parts List

Page 39

PARTS LIST

Models VC42N, VVC42N, VC42P, VVC42P, cgcDV42nr and cgcDV42pr

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 37 of this manual.

KEY

PART

 

 

NO.

NUMBER

DESCRIPTION

QTY.

1

**

Firebox Assembly

2

**

Face Weldment

3

108328-01

Door Assembly

 

108328-02

Door Assembly (V Models Only)

4

108331-01

Top Louver Assembly

5

108331-02

Bottom Louver Assembly

6

**

Fireplace Top

7

**

Fireplace Top Insulation

8

**

Fireplace Surround

9

109082-01

Heat Shield

10

116216-01

Log Set with Grate Assembly

11

116338-01

Right Burner Log

12

116339-01

Left Burner Log

13

See Below

Left Refractory Brick Panel

14

See Below

Rear Refractory Brick Panel

15

See Below

Right Refractory Brick Panel

16 108455-01 Screen Rod

17 107840-01 Screen

18

11418

Push-On Nut

19

14123

Strain Relief

20

21171

Gas Knock-Out Cover

21

24353

Handy Box Assembly

22

24460

Gas Conduit Assembly

23

116211-01

Burner Assembly (Natural Gas)(See page 40)

 

116211-02

Burner Assembly (Propane/LP Gas) (See page 40)

 

116211-05

Burner Assembly for High Altitude Models (See page 40)

24

116375-01

Plenum

 

 

 

PARTS AVAILABLE - NOT SHOWN

 

 

 

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

2

2

1

2

1

1

1

1

1

1

25487

Lava Rock/Bag Assy

27253

Notice Label

55240

Vent Label

116388-01

Grate Finial

** Part not available for field replacement.

REFRACTORY BRICK PANELS

CGCDV42NR

CGCDV42PR

VVC42NB

VC42NB VVC42PB VC42NH VVC42NH

VC42PB VVC42NB-HA VC42PH VVC42PH DESCRIPTION

1

1

1

2

QTY

111299-02 111299-01

111297-02 111297-01

111298-02 111298-01

111302-02

111302-01

Left Refractory Brick Panel

111300-02

111300-01

Rear Refractory Brick Panel

111301-02

111301-01

Right Refractory Brick Panel

1

1

1

116236-01E

www.desatech.com

39

Image 39
Contents What to do if YOU Smell GAS Table of Contents Safety Information High traffic areas Product IdentificationLocation and space requirements Product FeaturesPre-Installation Preparation Local CodesVenting clearances Clearances42 1067 mm Front 36 914 mm Top of Standoffs Vent See ventingFraming and finishing Noncombustible mantels at any height aboveFireplace Termination CAP AIR Supply Inlet GAS Meter Location of Termination CapInstallation Precautions Venting Installation InstructionsInstallation Planning Installing Horizontal Vent Cap Noncombustible Exterior Round Termination Ground Floor InstallationRecommended Applications Corner ground floor installation Snorkel Termination InstallationHorizontal System Installation Using TWO 90 Elbows Installation for vertical termination Flat Ceiling InstallationConnect a section of pipe and extend up through the hole Twist-lock the vent cap onto the last section of vent pipe Vertical Venting High Altitude InstallationDesa 5/8 Pipe & Vent Kits Number Description Parts list for venting kits and componentsPlug in blower power cord Fireplace InstallationInstalling optional blower accessories Model BK InstallationBlower Model BKT Model BKT InstallationInstalling Gas Piping to Fireplace Location Blower Wiring DiagramInstallation Items Needed Propane/LP Supply TankExternal Regulator Vent Pointing Down Connecting Fireplace to GAS SupplyDisconnect fireplace and its individual equip Checking GAS ConnectionsTest Pressures Equal To or Less Than Psig 3.5 kPa Close equipment shutoff valve see FigureTurn off fireplace see To Turn Off Gas to Ap- pliance, Installing optional wall Mount Switch gwmS2Pressure Testing Fireplace Gas Connections Installing Remote ReceiverRemoving/Replacing Glass Door Removing Louver PanelsRemoving Glass Door Installing lava rock and glowing embers Installing Brick liner Models BL42DASA and BL42DHASACleaning Glass Door Close top and bottom louvers For your safety Read before lightingOperating Fireplace Lighting InstructionsRemote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Optional Hand-HeldThermostat Series Model HRC200 On/Off Series Model HRC100Inspecting Burners Operating optional blower accessoryPilot assembly Key Pad Lock FeatureCleaning Maintenance Burner Flame PatternGlass Door Pilot and burners LogsVenting system Observed Problem Possible Cause Remedy TroubleshootingLong enough Control knob pressed Problem could be caused byBurner orifice clogged Clean burner see Cleaning Is lit After pilot lights, keep gasCold Minute Air in gas line Operate burner until air is When burner is lit HI position when burner isOr shut off Service person Remote does not function Tery power is lowStatement above Specifications Replacement PartsService Hints Technical ServiceModels VC42N, VVC42N, VC42P, VVC42P, cgcDV42nr and cgcDV42pr Illustrated Parts BreakdownParts List 19 18 Burner Pan Assembly Accessories Wall mounted thermostat control kit gwmt1 Not Shown Wall mounted on/off switch gwmS2 Not ShownWarranty Information Keep this WarrantyLimited Warranty DIRECT-VENT Fireplace

(V)VC42P, CGCDV42PR, VC42N, CGCDV42NR, VC42P, CGCDV42PR specifications

Desa (V)VC42P, CGCDV42PR, VC42N, CGCDV42NR, VC42P, and CGCDV42PR are a range of sophisticated heating solutions that exemplify modern design and efficiency. Designed for residential comfort, these models offer advanced features and technologies that set them apart in the market.

One of the most notable characteristics of these units is their innovative heating technology. They utilize advanced vented and vent-free systems, allowing for flexible installation options based on the needs of the home. These systems efficiently convert fuel into heat, ensuring a high level of warmth with minimal energy consumption. The models cater to various fuel types, including natural gas and propane, allowing consumers to choose the most economical option for their heating needs.

The Desa models are engineered with user-friendly controls, featuring modern thermostats that provide precise temperature regulation. This allows for enhanced comfort and energy efficiency, as users can program the units to operate only when needed. Many of the models come equipped with remote control functionality, offering added convenience for adjusting settings from the comfort of one's sofa.

In terms of safety, these heaters are built with robust safety features such as automatic shut-off systems and oxygen depletion sensors, ensuring that air quality remains safe and that the units operate without risk. This attention to safety is crucial for consumer peace of mind, particularly in homes with children or pets.

Aesthetically, the Desa models shine with an attractive design that complements various interior styles. They are available in multiple finishes and sizes, allowing homeowners to choose a heater that best fits their space and decor. Whether placed in a living room, bedroom, or hallway, these heaters not only provide warmth but also add to the overall ambiance of the home.

Durability is another key characteristic of the Desa series. Constructed with high-quality materials, these heaters promise longevity and reliability. They are designed to withstand the rigors of daily use while maintaining efficiency and effectiveness.

In conclusion, the Desa (V)VC42P, CGCDV42PR, VC42N, CGCDV42NR, VC42P, and CGCDV42PR offer a comprehensive heating solution that combines efficiency, safety, design, and technology. Ideal for modern households, these units represent a smart choice for anyone looking to enhance their home’s comfort and warmth.