Desa VYGF33NR installation manual Observed Problem Possible Cause Remedy

Page 18

DESA INTERNATIONAL

UNVENTED NATURAL GAS FIREPLACE

TROUBLESHOOTING

Continued

 

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

Burner does not light after ODS/pilot is lit

1.

Burner orifice clogged

1.

Clean burner (see Cleaning and Mainte-

 

 

 

 

 

nance, page 21) or replace burner orifice

 

 

2.

Inlet gas pressure is too low

2.

Contact local natural gas company

 

 

3.

Burner orifice diameter is too small

3.

Replace burner orifice

 

 

4.

Thermopile leads disconnected or im-

4.

Reconnect leads (see Wiring Diagram,

 

 

 

properly connected

 

page 20)

 

 

5.

Burners will not come on in remote po-

5.

Replace battery in transmitter and re-

 

 

 

sition

 

ceiver

 

 

 

 

 

 

 

 

Delayed ignition burner

1.

Manifold pressure is too low

1.

Contact local natural gas company

 

 

2.

Burner orifice clogged

2.

Clean burner (see Cleaning and Mainte-

 

 

 

 

 

nance, page 21) or replace burner orifice

 

 

 

 

 

 

 

 

Burner backfiring during combustion

1.

Burner orifice is clogged or damaged

1.

Clean burner (see Cleaning and Mainte-

 

 

 

 

 

nance, page 21) or replace burner orifice

 

 

2.

Damaged burner

2.

Replace damaged burner

 

 

3.

Gas regulator defective

3.

Replace gas control

 

 

 

 

 

 

 

 

Slight smoke or odor during initial operation

1.

Not enough air

1.

Check burner for dirt and debris. If

 

 

 

 

 

found, clean burner (see Cleaning and

 

 

 

 

 

Maintenance, page 21)

 

 

2.

Gas regulator defective

2.

Replace gas control

 

 

3.

Residues from manufacturing processes

3.

Problem will stop after a few hours of

 

 

 

and logs curing

 

operation

 

 

 

 

 

 

 

 

Moisture/condensation noticed on windows

1.

Not enough combustion/ventilation air

1.

Refer to Air for Combustion and Venti-

 

 

 

 

 

lation requirements (page 4)

 

 

 

 

 

 

 

 

Heater produces a whistling noise when

1.

Turning control knob to HI position

1.

Turn control knob to LO position and

 

burner is lit

 

when burner is cold

 

let warm up for a minute

 

 

2.

Air in gas line

2.

Operate burner until air is removed from

 

 

 

 

 

line. Have gas line checked by local

 

 

 

 

 

natural gas company

 

 

3.

Air passageways on heater blocked

3.

Observe minimum installation clear-

 

 

 

 

 

ances (see pages 8 through 10)

 

 

4.

Dirty or partially clogged burner orifice

4.

Clean burner (see Cleaning and Mainte-

 

 

 

 

 

nance, page 21) or replace burner orifice

 

 

 

 

 

 

 

White powder residue forming within burner box or on adjacent walls or furniture.

1.When heated, vapors from furniture pol- ish, wax, carpet cleaners, etc. turn into white powder residue.

1.Turn heater off when using furniture pol- ish, wax, cleaners, or similar products.

18

104352

Image 18
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASSafety Information Desa International Unvented Natural GAS FireplaceLocal Codes Remote Control AccessoriesProduct Identification UnpackingProduct Features AIR for Combustion and VentilationProviding Adequate Ventilation AIR for Combustion Ventilation Determining AIR Flow for Fireplace LocationDetermining if You Have a Confined or Unconfined Space Building Ventilation AIRVentilation Air From Inside Ventilation Air From OutdoorsOptional GA3700 and GA3700T Blower Accessory InstallationInstalling Hood Check GAS TypeInstallation Clearances Conventional Fireplace InstallationMinimum Wall and Ceiling Clearances see Figure BUILT-IN Fireplace Installation Location of Nailing FlangesInstalling GAS Piping to Fireplace Location Mantel Clearances for Built-In InstallationInstallation Items Needed Connecting Fireplace to GAS Supply Removing Log Base Assembly From FireplacePressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections Installing Logs Installing One Piece Log SetFor Your Safety Read Before Lighting Operating FireplaceLighting Instructions Manual Lighting Procedure To Turn OFF GAS To ApplianceOptional Remote Operation Pilot Flame Pattern Inspecting BurnersOptional Blower Operation Main BurnerTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Technical Service Wiring DiagramSpecifications Service HintsODS/PILOT and Burner Cleaning and MaintenanceReplacement Parts LogsAccessories WALL-MOUNT Thermostat Switch GWMT1 Receiver and HAND-HELD Thermostat Remote Control KIT GhrctReceiver and HAND-HELD Remote Control KIT Ghrc WALL-MOUNT ON/OFF Switch GWMS2Illustrated Parts Breakdown Remote Ready Model VYGF33NRParts List KEY Part Number Description QTYFireplace VYGF33NR Parts List Warranty Information