Desa VV36EPC1 installation manual Connecting Fireplace to GAS Supply, Gas Connection

Page 19

FIREPLACE INSTALLATION

Installing Gas Piping to Fireplace Location (Cont.) Connecting Fireplace To Gas Supply

19

FIREPLACE INSTALLATION

Continued

We recommend that you install a sediment trap/drip leg in supply line as shown in Figure 31. Locate sediment trap/drip leg where it is within reach for cleaning. Install in piping system between fuel supply and fireplace. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace gas con- trols. If sediment trap/drip leg is not installed or is installed wrong, fireplace may not run properly.

CSA Design-Certified

Equipment Shutoff Valve

with 1/8" NPT Tap*

CONNECTING FIREPLACE TO GAS SUPPLY

Installation Items Needed

5/16" hex socket wrench or nut-driver

sealant (resistant to propane/LP gas, not provided)

1.Open lower louver door panel by gently pulling forward.

2.Route flexible gas line (provided by installer) from equipment shutoff valve to fireplace. Route flexible gas supply line through one of the access holes on side of fireplace.

3.Attach flexible gas line from gas supply to control valve (see Figure 32).

4.Check all gas connections for leaks. See Checking Gas Con- nections.

Approved Flexible

Gas Line

3" Minimum

Natural - From Gas Meter (5.5" W.C. to 10.5"

W.C. Pressure)

Propane/LP From External Regulator (11" W.C. to 14" W.C. Pressure)

 

Red Surface Indicates

Equipment

For Propane/LP Use Only

Flexible Gas Line

Shutoff Valve

Do NOT Kink

1/2" NPT Incoming

 

 

Gas Line

Inlet Pressure Tap

Outlet Pressure Tap

 

Cap Pipe Nipple Tee Joint

Note: Wire Connections Not Shown for Clarity

Figure 31 - Gas Connection

Sediment Trap/Drip Leg

Figure 32 - Connecting Flexible Gas Line to Electronic Valve

*The CSA design-certified equipment shutoff valve may be sup- plied with the appliance or you can purchase it from your retailer.

For morevisit www..com

111253-01E

Image 19
Contents For Your Safety OWNER’S Operation Installation ManualFor Your Safety What to do if YOU Smell GAS Safety Information Table of ContentsLocal Codes Product IdentificationPRE-INSTALLATION Preparation Product FeaturesLocation and Space Requirements Framing and Finishing ClearancesBalcony with Perpendicular Side Wall Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Siding Standoff Combustible Exterior Ground Floor Installation Horizontal Termination ConfigurationsCorner Installation Venting with Two 90 Elbows Flat Ceiling Installation Installation for Vertical TerminationVertical Termination Configurations Parts Lists for Venting Kits and Components High Altitude InstallationDesa 5/8 Pipe & Vent Kits Check GAS Type Fireplace InstallationInstalling Optional Blower Accessory Model BK InstallationAttaching Speed Control to Firebox Model BKT InstallationBlower Wiring Diagram Installing GAS Piping to Fireplace LocationInstallation Items Needed Gas Connection Connecting Fireplace to GAS SupplyPressure Testing Fireplace Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Removing Glass Door Cleaning Glass DoorREMOVING/REPLACING Glass Door Removing Louver PanelsInstalling Rear Brick Panel Installing LOGS, Lava Rock and Glowing EmbersInstalling Log No Installing Log No Wall Switch Installation Wiring DiagramOptional Remote Control To Turn OFF GAS To Appliance For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsBurner Flame Pattern Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause Remedy TroubleshootingGas leak. See Warning statement at Illustrated Parts Breakdown Illustrated Parts BreakdownParts List Parts ListNG #47 5 LP #56 KEY Part Number Description QTY Burner Assembly for ModelsSpecifications Replacement PartsService Hints Technical ServiceOwners Registration Form Postage Required Accessories Warranty Information

VV36EPC1 specifications

Desa VV36EPC1 is a state-of-the-art compact village generator known for its robust performance and reliability in various applications. As a versatile energy solution, it is particularly well-suited for remote areas, outdoor events, and emergency backup systems.

One of the main features of the VV36EPC1 is its superior power output, providing up to 36 kVA, making it capable of handling significant electrical loads. This generator is equipped with a powerful diesel engine that ensures efficient fuel consumption while delivering consistent power generation. The engine is designed to operate quietly, minimizing noise pollution, which is essential for residential or community use.

The VV36EPC1 incorporates advanced technology for energy management and safety. The digital control panel presents real-time data on voltage, frequency, and operating hours, allowing users to monitor performance easily. Additionally, it features an automatic voltage regulator (AVR) that stabilizes voltage output, preventing equipment damage caused by fluctuations.

Another standout characteristic of the VV36EPC1 is its rugged build quality. Constructed with durable materials, this generator is designed to withstand harsh environmental conditions. Its weather-resistant enclosure protects internal components from rain and dust, ensuring longevity and reliability during operation.

Portability is also a significant advantage of the VV36EPC1. It includes built-in wheels and a convenient lifting handle, making it easy to transport across various terrains. This feature makes it an excellent choice for construction sites, catering, or festivals, where mobility is essential.

In terms of safety, the VV36EPC1 offers multiple safeguards, including low oil shutdown and overload protection. These features ensure the generator operates safely, automatically shutting down when oil levels are low or if the load exceeds its capacity.

In summary, the Desa VV36EPC1 is a powerful, reliable, and portable generator, equipped with advanced monitoring technology and essential safety features. Whether for recreational purposes or critical power supply needs, the VV36EPC1 stands out as an optimal choice for diverse applications, providing peace of mind with its dependable performance and durability.