Desa VV36EPC1 REMOVING/REPLACING Glass Door, Removing Louver Panels, Removing Glass Door

Page 21

FIREPLACE INSTALLATION

Continued

REMOVING/REPLACING GLASS DOOR

CAUTION: Do not operate this fireplace with a broken glass door panel or without the glass door panel securely in place. For replacement part infor- mation see Replacement Parts, page 34.

CAUTION: Wear gloves and safety glasses while handling or removing broken glass. Do not remove if glass is hot. Keep children and pets away from glass.

WARNING: If fireplace has been running, turn off and unplug fireplace. Let cool before removing glass door or louvers.

Removing Louver Panels

Remove the top and bottom louver panels by simultaneously pulling both top end spring latches towards the center of the appliance until they are disengaged from the locating holes (see Figure 36). Repeat for bottom spring latches and pull the louvers outward. To install or replace items removed, simply reverse the procedures above.

Spring Latch

Louver Panel

Figure 36 - Removing Louver Panel

FIREPLACE INSTALLATION

21

Removing/Replacing Glass Door

Removing Glass Door

If replacement of glass is necessary, the entire assembly, glass and frame, must be replaced. If glass is broken, wear gloves and tape the remaining fragments onto the frame.

1.Remove screen assembly by pushing the rod either left or right and then down and forward to remove screen/rod assembly from the firebox. Set assembly aside.

2.Lift up on latches to unlock. There are two on top of firebox and two below firebox that hold glass door in place (see Figure 37).

3.While holding glass door to prevent it from falling and caus- ing injury, remove the five screws from the hinge located on the left side of door frame assembly (see Figure 37).

4.Remount the new frame at the hinge with five new screws before closing door. This will ensure seating of the gasket.

5.Close glass door frame. Lock latches by placing the bar under the tab on door and pushing down and back on latch (see Figure 37).

6.Replace screen/rod assembly by reversing step 1.

7.Replace louvers by reversing procedure under Removing Lou- ver Panels.

Latch Unlock

Lock

Hinge

Screw

Glass

Frame

Assembly

Figure 37 - Removing/Replacing Glass Door

Cleaning Glass Door

See Cleaning and Maintenance on page 27.

For morevisit www..com

111253-01E

Image 21
Contents OWNER’S Operation Installation Manual For Your SafetyFor Your Safety What to do if YOU Smell GAS Safety Information Table of ContentsLocal Codes Product IdentificationProduct Features PRE-INSTALLATION PreparationLocation and Space Requirements Framing and Finishing ClearancesBalcony with Perpendicular Side Wall Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Siding Standoff Combustible Exterior Ground Floor Installation Horizontal Termination ConfigurationsCorner Installation Venting with Two 90 Elbows Flat Ceiling Installation Installation for Vertical TerminationVertical Termination Configurations High Altitude Installation Parts Lists for Venting Kits and ComponentsDesa 5/8 Pipe & Vent Kits Installing Optional Blower Accessory Fireplace InstallationModel BK Installation Check GAS TypeAttaching Speed Control to Firebox Model BKT Installation Installing GAS Piping to Fireplace Location Blower Wiring Diagram Installation Items Needed Gas Connection Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections REMOVING/REPLACING Glass Door Cleaning Glass DoorRemoving Louver Panels Removing Glass DoorInstalling Rear Brick Panel Installing LOGS, Lava Rock and Glowing EmbersInstalling Log No Installing Log No Wiring Diagram Wall Switch InstallationOptional Remote Control Operating Fireplace For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To AppliancePilot Assembly Operating Optional Blower AccessoryInspecting Burners Burner Flame PatternGlass Door Cleaning MaintenancePilot and Burners LogsObserved Problem Possible Cause Remedy TroubleshootingGas leak. See Warning statement at Illustrated Parts Breakdown Illustrated Parts BreakdownParts List Parts ListNG #47 5 LP #56 KEY Part Number Description QTY Burner Assembly for ModelsService Hints Replacement PartsTechnical Service SpecificationsOwners Registration Form Postage Required Accessories Warranty Information