Desa VV36EPC1 Cleaning Maintenance, Glass Door, Pilot and Burners, Logs, Venting System

Page 27

CLEANING AND MAINTENANCE

Glass Door

Pilot and Burners

Logs

Venting System

27

CLEANING AND

MAINTENANCE

WARNING: Turn off fireplace and let cool before cleaning.

CAUTION: You must keep control areas, burners, and circulating air passageways of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, bedding mate- rial, pet hair, etc.

GLASS DOOR

WARNING: Handle glass door panel with care. Do not strike, slam, or otherwise abuse glass. Do not operate fireplace with the glass door removed, cracked, or broken.

WARNING: Do not use abrasive cleaners as this maydamageglass.Useanonabrasivehouseholdglass cleaner to clean glass. Do not clean glass when hot.

Glass must be cleaned periodically. During start-up it is normal for condensation to form on the inside of the glass causing lint, dust, and other airborne particles to cling to the glass surface. During initial start-up a slight film may form on the glass due to paint curing. The glass should be cleaned several times with a non-ammonia, non- abrasive household cleaner and warm water after the first two weeks of operation. Thereafter, clean the glass two or three times during each heating season, depending on the usage and circumstances present. Refer to Removing/Replacing Glass Door on page 21 of this manual when removing glass door for cleaning.

WARNING: Only parts supplied by the manufac- turer should be used when replacing broken or damaged glass door panel (see Replacement Parts, page 34). This glass door panel is a complete unit. No substitute materials may be used.

CAUTION: Wear gloves and safety glasses while handling or removing broken glass. Do not remove if glass is hot. Keep children and pets away from glass.

If glass has been broken, carefully remove glass door (see Remov- ing/Replacing Glass Door, page 21). Vacuum all glass pieces with a shop vac.

CAUTION: Do not vacuum if pieces are hot.

Use only the tempered glass door replacement intended for this fireplace (see Replacement Parts, page 30 for detail on ordering). No substitutions may be made. See Removing/Replacing Glass Door, page 21 for instructions for replacing glass door.

WARNING: Do not operate fireplace with the glass door removed, cracked, or broken.

PILOT AND BURNERS

Remove ember material before cleaning burners and replace when cleaning is complete.

Burner and controls should be cleaned with compressed air to remove dust, dirt, or lint.

Use a vacuum cleaner or small, soft bristled brush to remove excess dust, dirt, or lint.

LOGS

If you remove logs for cleaning, refer to Installing Logs, Lava Rock, and Glowing Embers, pages 22 and 23, to properly re- place logs.

Use a vacuum cleaner to remove any carbon buildup on logs.

Replace log(s) if broken. See Replacement Parts on page 34.

Replace ember material periodically as needed. See Replace- ment Parts on page 34.

VENTING SYSTEM

Conduct annual inspection of the venting system following these guidelines:

1.Check areas of venting system that are exposed to the weather for corrosion (rust spots or streaks and, in extreme cases, holes). Have these items replaced immediately by a qualified service person.

2.Remove the vent cap and shine a flashlight into the vent. Re- move any foreign material.

3.Check for evidence of excessive condensation. Continuous condensation can cause corrosion of caps, pipes, and fittings and can be caused by having excessive lateral runs, too many elbows, or exterior portions of the system being exposed to cold weather.

4.Inspect joints to verify that no pipe section or fitting has been disturbed and loosened. Check mechanical supports such as wall straps for rigidity.

For morevisit www..com

111253-01E

Image 27
Contents OWNER’S Operation Installation Manual For Your SafetyFor Your Safety What to do if YOU Smell GAS Safety Information Table of ContentsLocal Codes Product IdentificationProduct Features PRE-INSTALLATION PreparationLocation and Space Requirements Framing and Finishing ClearancesBalcony with Perpendicular Side Wall Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Siding Standoff Combustible Exterior Ground Floor Installation Horizontal Termination ConfigurationsCorner Installation Venting with Two 90 Elbows Flat Ceiling Installation Installation for Vertical TerminationVertical Termination Configurations High Altitude Installation Parts Lists for Venting Kits and ComponentsDesa 5/8 Pipe & Vent Kits Check GAS Type Fireplace InstallationInstalling Optional Blower Accessory Model BK InstallationAttaching Speed Control to Firebox Model BKT InstallationInstalling GAS Piping to Fireplace Location Blower Wiring DiagramInstallation Items Needed Gas Connection Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections Removing Glass Door Cleaning Glass DoorREMOVING/REPLACING Glass Door Removing Louver PanelsInstalling Rear Brick Panel Installing LOGS, Lava Rock and Glowing EmbersInstalling Log No Installing Log No Wiring Diagram Wall Switch InstallationOptional Remote Control To Turn OFF GAS To Appliance For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsBurner Flame Pattern Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause Remedy TroubleshootingGas leak. See Warning statement at Illustrated Parts Breakdown Illustrated Parts BreakdownParts List Parts ListNG #47 5 LP #56 KEY Part Number Description QTY Burner Assembly for ModelsSpecifications Replacement PartsService Hints Technical ServiceOwners Registration Form Postage Required Accessories Warranty Information

VV36EPC1 specifications

Desa VV36EPC1 is a state-of-the-art compact village generator known for its robust performance and reliability in various applications. As a versatile energy solution, it is particularly well-suited for remote areas, outdoor events, and emergency backup systems.

One of the main features of the VV36EPC1 is its superior power output, providing up to 36 kVA, making it capable of handling significant electrical loads. This generator is equipped with a powerful diesel engine that ensures efficient fuel consumption while delivering consistent power generation. The engine is designed to operate quietly, minimizing noise pollution, which is essential for residential or community use.

The VV36EPC1 incorporates advanced technology for energy management and safety. The digital control panel presents real-time data on voltage, frequency, and operating hours, allowing users to monitor performance easily. Additionally, it features an automatic voltage regulator (AVR) that stabilizes voltage output, preventing equipment damage caused by fluctuations.

Another standout characteristic of the VV36EPC1 is its rugged build quality. Constructed with durable materials, this generator is designed to withstand harsh environmental conditions. Its weather-resistant enclosure protects internal components from rain and dust, ensuring longevity and reliability during operation.

Portability is also a significant advantage of the VV36EPC1. It includes built-in wheels and a convenient lifting handle, making it easy to transport across various terrains. This feature makes it an excellent choice for construction sites, catering, or festivals, where mobility is essential.

In terms of safety, the VV36EPC1 offers multiple safeguards, including low oil shutdown and overload protection. These features ensure the generator operates safely, automatically shutting down when oil levels are low or if the load exceeds its capacity.

In summary, the Desa VV36EPC1 is a powerful, reliable, and portable generator, equipped with advanced monitoring technology and essential safety features. Whether for recreational purposes or critical power supply needs, the VV36EPC1 stands out as an optimal choice for diverse applications, providing peace of mind with its dependable performance and durability.