2.Remove the screw and retainer bracket at the top of the brick liner panel in the back of the firebox. Do not let the panel fall after the bracket is removed. Care- fully remove the rear firebrick liner panel from the firebox.

CAUTION: Do not let the fire- brick liner panel fall after the bracket is removed.

3.Carefully lift and remove the bottom firebrick floor from bottom of firebox.

Bracket

Screw

4.Remove the four Phillips screws in fire- box bottom.

5.Use the two finger holes in the firebox bottom to carefully lift up and remove the firebox bottom.

6.Locate duplex outlet mounted to sup- port bracket in lower right hand side of firebox. Remove screw holding duplex outlet to support bracket in bottom of firebox. Remove duplex outlet (see Fig- ure 19).

7.Clamp electrical cable hard-wiring into firebox through smallest hole using strain relief fitting provided (see Fig- ure 20).

8.Connect electrical cable to duplex out- let. Match wire colors to those on du- plex outlet. Be sure to connect ground wire.

9.Replace duplex outlet with screw.

10.You may now install GA3700 Blower Accessory if desired. See installation instruction sheet included with blower kit.

11.Replace firebox bottom with four Phillips screws.

12.Carefully replace firebrick panels in reverse order (see Figures 15, 16, and 17, pages 10 and 11).

Electric

Cables

Duplex

Outlet

Support

Bracket

Screw

Figure 19 - Removing Duplex Outlet

Strain

Relief

Fitting

Electric

Cables

Small Hole

Rear Firebrick

Liner Panel

Figure 16 - Removing Rear Firebrick Liner Panel

Figure 17 - Removing Bottom Firebrick Floor

Figure 20 - Installing Strain Relief Fitting into Electrical Access Hole

Screws

Finger

Holes

Firebox

Bottom

Screws

Figure 18 - Removing Firebox Bottom

Continued

103451

11

Image 11
Contents What to do if YOU Smell GAS Unvented VENT-FREEUnpacking Safety InformationLocal Codes Product SpecificationsProviding Adequate Ventilation Product FeaturesLocating Firebox AIR for Combustion and VentilationDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining AIR Flow for Firebox Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Minimum Wall and Ceiling Clearances see Figure InstallationInstallation Clearances Mantel Clearances for Conventional InstallationMantel Clearances for Built-In Installation BUILT-IN Firebox InstallationAttaching Firebox to Wall Studs Installing Firebox Using Optional Accessory MantelsFor Built-in Installation of Circulating Models Only Installing GAS LineHARD-WIRING Firebox Removing Duplex Outlet Parts Under Warranty Technical ServiceReplacement Parts Installing Fireplace ScreenManual Shutoff Valve GA5010 AccessoriesCabinet Mantel Accessory with Firebox Perimeter Brass Trim Blower Accessory GA3700FB36NCA and FB42NC Illustrated Parts BreakdownFirebox FB36NCA and FB42NC Parts ListFB36CA and FB42C KEY Part Number Description QTY FB36CA FB42C Firebox FB36CA and FB42CVanguard Unvented VENT-FREE Logmate Firebox 103451 Warranty Information