Desa FB36NCA, FB42NC, FB36CA, FB42C Ventilation AIR, Ventilation Air From Inside Building

Page 6

VANGUARD

UNVENTED (VENT-FREE) LOGMATE™ FIREBOX

AIR FOR COMBUSTION AND VENTILATION

Continued

VENTILATION AIR

Ventilation

Grills

Into Adjoining

12"

Ventilation Grills

Into Adjoining Room,

Room,

Or

Option 2

Option 1

Remove

Ventilation Air From Inside Building

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 4). You can also remove door into adjoining room (see op- tion 3, Figure 4). Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

WARNING: Rework work- sheet, adding the space of the

adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces.

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two per- manent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.

Door into Adjoining Room, Option 3

12"

Figure 4 - Ventilation Air from Inside

Ventilated

Outlet Attic

Air

Outlet

 

Air

To Attic

 

To

Crawl

Space

Inlet

Air

Inlet Air

 

Ventilated

 

 

Crawl Space

 

 

Figure 5 - Ventilation Air from Outdoors

6

103451

Image 6
Contents Unvented VENT-FREE What to do if YOU Smell GASSafety Information Local CodesUnpacking Specifications ProductAIR for Combustion and Ventilation Product FeaturesLocating Firebox Providing Adequate VentilationAIR for Combustion Ventilation Determining AIR Flow for Firebox LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Mantel Clearances for Conventional Installation InstallationInstallation Clearances Minimum Wall and Ceiling Clearances see FigureBUILT-IN Firebox Installation Mantel Clearances for Built-In InstallationInstalling Firebox Using Optional Accessory Mantels Attaching Firebox to Wall StudsInstalling GAS Line HARD-WIRING FireboxFor Built-in Installation of Circulating Models Only Removing Duplex Outlet Installing Fireplace Screen Technical ServiceReplacement Parts Parts Under WarrantyBlower Accessory GA3700 AccessoriesCabinet Mantel Accessory with Firebox Perimeter Brass Trim Manual Shutoff Valve GA5010Illustrated Parts Breakdown FB36NCA and FB42NCParts List Firebox FB36NCA and FB42NCFB36CA and FB42C Firebox FB36CA and FB42C KEY Part Number Description QTY FB36CA FB42CVanguard Unvented VENT-FREE Logmate Firebox 103451 Warranty Information