3.Carefully set firebox in front of rough opening with back of firebox inside wall opening. IMPORTANT: If install- ing Brass Trim Kit GA6091 or GA6092, see instructions included with brass trim accessory. You must install shoulder screws from brass trim kit now.

4.Carefully insert firebox into rough opening.

5.Attach firebox to wall studs using nails or wood screws through holes in nail- ing flange (see Figure 9).

6.If using optional GA6091 or GA6092 Brass Trim Kit, install the trim after fi- nal finishing and/or painting of wall. See instructions included with brass trim accessory for attaching brass trim.

7.Install and properly test gas log heater. Follow installation instructions in- cluded with the vent-free gas log heater that is being installed.

IMPORTANT: When finishing your fire- box, combustible materials such as wall board, gypsum board, sheet rock, drywall, plywood, etc. may be butted up next to the sides and top of the firebox. Combustible materials should never overlap the firebox front facing.

WARNING: Do not allow any combustable materials to over- lap the firebox front facing.

Nails or

Wood

Screws

Nailing

Flanges

Figure 9 - Attaching Firebox to Wall Studs

IMPORTANT: Non-combustible materials such as brick, tile, etc. may overlap the front facing, but should never cover any neces- sary openings like louvered slots.

WARNING: Do not allow non- combustible materials to cover any necessary openings like lou- vered slots.

WARNING: Never modify or cover the louvered slots on the front of the firebox.

WARNING: Use only non-com- bustible mortar or adhesives when overlapping the front fac- ing with non-combustible facing material.

INSTALLING FIREBOX USING OPTIONAL ACCESSORY MANTELS

NOTICE: A qualified service per- son must install firebox. Follow all local codes.

This firebox may be installed using a cabi- net mantel accessory against a wall in your home. The firebox and cabinet mantel can be installed directly on the floor. A brass trim kit is included with the mantel acces- sory GM103U or GM105U (see Accesso- ries, page 13).

1.Assemble cabinet mantel accessory and the brass trim kit. Assembly instruc- tions are included with each accessory.

2.If using an optional GA3700 Blower (circulating models only), install a properly grounded, 120 volt three- prong electrical outlet at firebox loca- tion if an outlet is not there. If possible, locate outlet so cabinet mantel will cover it when installed (see Figure 10).

3.Install gas piping to firebox location. See Installing Gas Line, page 10. You may have to cut an access hole in the floor or wall to run gas line to firebox. Make sure to locate access hole so cabi- net mantel will cover it when installed (see Figure 10).

4.Place cabinet mantel on floor in desired location. Make sure mantel is flush against wall.

5.Break off nailing flanges with hammer or pliers (see Figure 11).

Cabinet

Mantel

Electrical

Outlet

Gas Line

Gas

Access Hole

Piping

(Either Side

 

of Firebox)

 

Figure 10 - Installing Cabinet Mantel

Nailing Flanges

Figure 11 - Location of Nailing Flanges (Two on Each Side)

Continued

103451

9

Image 9
Contents What to do if YOU Smell GAS Unvented VENT-FREESafety Information Local CodesUnpacking Product SpecificationsLocating Firebox Product FeaturesAIR for Combustion and Ventilation Providing Adequate VentilationAIR for Combustion Ventilation Determining AIR Flow for Firebox LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Clearances InstallationMantel Clearances for Conventional Installation Minimum Wall and Ceiling Clearances see FigureMantel Clearances for Built-In Installation BUILT-IN Firebox InstallationAttaching Firebox to Wall Studs Installing Firebox Using Optional Accessory MantelsInstalling GAS Line HARD-WIRING FireboxFor Built-in Installation of Circulating Models Only Removing Duplex Outlet Replacement Parts Technical ServiceInstalling Fireplace Screen Parts Under WarrantyCabinet Mantel Accessory with Firebox Perimeter Brass Trim AccessoriesBlower Accessory GA3700 Manual Shutoff Valve GA5010FB36NCA and FB42NC Illustrated Parts BreakdownFirebox FB36NCA and FB42NC Parts ListFB36CA and FB42C KEY Part Number Description QTY FB36CA FB42C Firebox FB36CA and FB42CVanguard Unvented VENT-FREE Logmate Firebox 103451 Warranty Information