Desa E36LH, E36LBH, E32LH, E32LB Cleaning Viewing Screen, Accessing Imaging Unit For Replacement

Page 22

MAINTENANCE

Continued

3.If upper back cabinet ribbons need re- placing, remove 4 Phillips screws holding corresponding bottom and top hanger brackets (see Figure 37, page 21).

4.Remove any loose or damaged ribbon material.

5.Cut an 18” strip of reflective ribbon and position top end about an inch above top bracket position (see Figure 37, page 21).

Note: Ribbon material should be ap- plied with reflective side up, should not be twisted or tangled, and should hang slightly loose to allow free movement. If additional parts are required, see Re- placement Parts, page 23.

6.Replace top hanger bracket using 2 Phil- lips screws removed in step 2 and tighten until reflective ribbon is held in place.

7.Replace bottom hanger bracket using 2 remaining Phillips screws to secure lower end of reflective ribbon.

8.If replacing reflective ribbons located in base, remove screws and washers at damaged ends of ribbon.

9.Cut a 9" long strip of ribbon and apply across each ribbon support bracket with shiny side facing up (see Figure 37, page 21).

10.Secure ribbon to brackets by replacing each washer at end of the ribbon and re- threading screws through the ribbon into each hole located on support brackets.

11.If replacing top reflective ribbons on base cover, cut a 3" section of ribbon and split down the middle. With shiny side up, attach with cellophane tape into rear edge of base cover opening (see Figure 37, page 21).

12.Readjust flame pennants (if removed). See Servicing Flame Pennants, page 19.

13.Reassemble imager. See Accessing Imaging Unit, page 18.

14.Center log bed over opening between viewing panel screen and grate.

15.Cover remaining hearth area with 1/4" of lava rock (provided), if desired.

Cleaning Viewing Screen

Clean viewing screen with an alcohol based, nonabrasive, residue free cleaner (premoist- ened hand wipes are ideal). Do not use glass cleaners with ammonium, abrasive scrubs or degreaser solvents of any kind.

Accessing Imaging Unit For Replacement

The imaging unit can be removed from inside the firebox for servicing or replacement:

1.Follow steps under Accessing Imaging Unit, on page 18.

2.Remove 4 hex screws on lower louver panel and detach louver assembly from front face (see Figure 38).

3.Rotate top edge of lower frame rail inward and lift upward until locking tabs detach from front face (see Figure 38).

4.Slide entire imaging unit forward and lift out through front opening (see Figure 39, page 23).

Note: An additional 3 feet of harness is tucked behind imager to permit removal without dis- connecting any control wiring.

Lower

Frame

Rail

Lower Panel

Lower Frame

Rail

Locking Tab

Figure 38 - Removing Lower Louver

Panel and Frame Rail

22

www.desatech.com

111076-01F

Image 22
Contents Electric Fireplace OWNER’S Operation and Installation Manual Table of Contents SafetyInstallation Product SpecificationLocating Fireplace Installation Clearances For mantel clearances see Figures 3BUILT-IN Installation Electrical InstallationRemoving Shipping Brace Features and Operation Lamps and lava RockAccessory Installation Optional Glass DoorsOptional Brick Liners Bifold doors may be removed for replacing or cleaningScrew Retainer Optional Heater AccessoryBracket Mount location with on I indicator Wired for convenienceHarness Strap Mounting Screws Heater Blower Assembly Knockout Plug Remove to Install Power SwitchHeater Circuit Diagrams Remount harness strap to blower mount, if removedConnecting Heater Wires Terminal D Switch Jumper Terminal L-5 LeadTroubleshooting Observed Problem Possible Cause RemedyWiring Diagram Heater Assembly Electrical DiagramMaintaining Motors MaintenanceReplacing Light Bulbs Removing/Replacing Control DoorServicing Control Panel Accessing Imaging Unit Viewing ScreenServicing Flame Pennants Screw Fan Assembly Posts for Blade ConnectorsServicing Fan Blower Base CoverReplacing Lamp Fixtures Locating Flame PennantsReplacing Reflective Ribbons Replacing Fixtures Shown without FIrebox for ClarityAccessing Imaging Unit For Replacement Cleaning Viewing ScreenRemove any loose or damaged ribbon material Parts Under Warranty Technical ServiceReplacement Parts Parts Not Under WarrantyParts Parts KEY Description Bifold Glass Door Kits AccessoriesPerimeter Trim Kits Fixed Glass Door KitsKeep this Warranty WarrantyLimited 1 Year Warranty

E32LB, E36L, E36LH, E32L, E32LH specifications

The Desa E32L, E32LBH, E32LH, E36LB, and E36LBH are part of a versatile range of container handling equipment designed for efficient operations in various industrial environments. These models are particularly known for their robust performance, durability, and user-friendly features, making them suitable for both indoor and outdoor applications.

The Desa E32L and E32LBH are characterized by their compact designs, which allow for easy maneuverability in tight spaces. These models are equipped with advanced lifting technologies, including hydraulic systems that ensure smooth and precise lifting. The E32L model is specifically designed for lighter loads, making it ideal for warehouses and manufacturing settings where space is limited.

On the other hand, the E32LBH variant adds a height-adjustable feature, allowing operators to adapt to different working conditions without compromising stability. This flexibility makes it a favored choice in varied environments, including distribution centers where changes in load height are common.

The E32LH model stands out with its extended reach capabilities. This feature is particularly beneficial in environments where access to tall or stacked goods is necessary, enhancing productivity by minimizing the need for additional equipment. The E32LH also maintains the core benefits of the E32 series, providing reliable performance with a strong focus on operator safety.

Shifting focus to the E36LB and E36LBH, these models cater to heavier lifting tasks. The E36 series incorporates enhanced lifting capacity and stability, essential for handling bulk materials or larger pallets. The robust build and powerful hydraulic systems offer improved performance in demanding applications, ensuring that heavy loads are transported safely and efficiently.

All models in the Desa E series are integrated with ergonomic features aimed at enhancing user comfort. This includes adjustable handles and controls that reduce operator fatigue during long shifts. Furthermore, safety features such as overload protection and anti-slip surfaces are standard, ensuring that operators can work confidently without compromising safety.

In terms of technology, the E series utilizes advanced engineering that emphasizes energy efficiency and low maintenance costs. The hydraulic systems are designed for longevity, and the overall construction of these machines is aimed at withstanding harsh industrial environments.

With a commitment to innovation and efficiency, the Desa E32L, E32LBH, E32LH, E36LB, and E36LBH models reflect modern advancements in material handling technology, making them invaluable assets for businesses seeking to optimize their operational productivity and safety.