Desa E32LBH, E36LH, E36LBH, E32LH installation manual BUILT-IN Installation, Electrical Installation

Page 5

INSTALLATION

Continued

BUILT-IN INSTALLATION

Built-in installations require a framed enclo- sure constructed of 2" x 4" or heavier lumber and sized in accordance with Figure 5. This allows unit to slide into opening and be nailed to stud at sides and top nailing flanges. These flanges accept 5/8" drywall or plywood board to finish unit flush to face. Optional trim ac- cessories are available that will extend 1/2" over rough edge of wall opening (see Acces- sories, page 25).

IMPORTANT: If installing a perimeter trim kit, you must install shoulder screws before insert- ing fireplace into opening. See instructions included with trim kit. If installing a mantel, you must follow clearance instructions (see Installation Clearances, page 4).

A hearth extension is suggested for a more pleasing appearance. The fireplace may be raised on a wood or non-combustible platform supporting its entire width and depth and extending in front of the fireplace as long as louvers are not obstructed.

Note: When installing fireplace in cold cli- mates against a non-insulated exterior wall, wall must be fully insulated in accordance with local building code.

Platform/Subflooring

VE32 = 32 5/8"

VE36 = 36 1/4"

VE32 = 15 7/8"

VE36 = 17 1/4"

VE32 = 34 5/8"

VE36 = 41 1/4"

Figure 5 - Framing Dimensions

 

 

 

 

 

These Dimensions

 

 

 

 

 

Allow for 11 5/8" of

VE32 = 37 5/8"

 

 

Clearance to Side

VE36 = 42 3/8"

 

 

Wall of Fireplace

 

 

 

 

 

and 10' Clearance

 

 

 

 

 

VE32 = 26 5/8"

 

 

to Perpendicular

VE36 = 29 3/8"

 

 

Side Walls

 

 

 

VE32 = 52 3/4"

 

11 5/8"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VE36 = 58 1/4"

 

Figure 6 - Corner Dimensions

ELECTRICAL INSTALLATION

WARNING: Any electrical re- wiring of this appliance must be done by a qualified electrician. This wiring must be done in ac- cordancewithlocalcodesand/or in the U.S.A. with the current, Na- tionalElectricalCodeANSI/NFPA No 70 and in Canada with CSA C22.1 Canadian Electric code.

This fireplace should be con- nected to a dedicated 15 Amp, circuit as other appliances may cause the circuit breaker to trip or fuse to blow when fireplace is in operation.

A junction box with universal strain adaptor is provided to hard wire unit to a 15 amp, 120 Volt 60 Hz grounded circuit. If necessary, junction box may be relocated to route sup- ply to left side.

1.Remove 2 screws and outer cover on right side (see Figure 7, page 6).

2.Remove inner screw securing junction box.

3.Slide junction box up until mounting tab is lined up to notch in outer cabinet.

4.Swing box out and slip retaining flange out through slot in outer cabinet.

5.Remove 2 screws and outer cover on left side and reattach on right side of outer cabinet.

111076-01Fwww.desatech.com

Image 5
Contents Electric Fireplace OWNER’S Operation and Installation Manual Safety Table of ContentsLocating Fireplace Product SpecificationInstallation For mantel clearances see Figures 3 Installation ClearancesElectrical Installation BUILT-IN InstallationRemoving Shipping Brace Lamps and lava Rock Features and OperationOptional Glass Doors Accessory InstallationScrew Bifold doors may be removed for replacing or cleaningOptional Brick Liners Bracket Optional Heater AccessoryRetainer Harness Strap Mounting Screws Heater Blower Assembly Wired for convenienceMount location with on I indicator Knockout Plug Remove to Install Power SwitchRemount harness strap to blower mount, if removed Heater Circuit DiagramsTerminal D Switch Jumper Terminal L-5 Lead Connecting Heater WiresObserved Problem Possible Cause Remedy TroubleshootingHeater Assembly Electrical Diagram Wiring DiagramReplacing Light Bulbs MaintenanceMaintaining Motors Removing/Replacing Control DoorServicing Control Panel Viewing Screen Accessing Imaging UnitServicing Fan Blower Screw Fan Assembly Posts for Blade ConnectorsServicing Flame Pennants Base CoverLocating Flame Pennants Replacing Lamp FixturesReplacing Fixtures Shown without FIrebox for Clarity Replacing Reflective RibbonsRemove any loose or damaged ribbon material Cleaning Viewing ScreenAccessing Imaging Unit For Replacement Replacement Parts Technical ServiceParts Under Warranty Parts Not Under WarrantyParts Parts KEY Description Perimeter Trim Kits AccessoriesBifold Glass Door Kits Fixed Glass Door KitsLimited 1 Year Warranty WarrantyKeep this Warranty

E32LB, E36L, E36LH, E32L, E32LH specifications

The Desa E32L, E32LBH, E32LH, E36LB, and E36LBH are part of a versatile range of container handling equipment designed for efficient operations in various industrial environments. These models are particularly known for their robust performance, durability, and user-friendly features, making them suitable for both indoor and outdoor applications.

The Desa E32L and E32LBH are characterized by their compact designs, which allow for easy maneuverability in tight spaces. These models are equipped with advanced lifting technologies, including hydraulic systems that ensure smooth and precise lifting. The E32L model is specifically designed for lighter loads, making it ideal for warehouses and manufacturing settings where space is limited.

On the other hand, the E32LBH variant adds a height-adjustable feature, allowing operators to adapt to different working conditions without compromising stability. This flexibility makes it a favored choice in varied environments, including distribution centers where changes in load height are common.

The E32LH model stands out with its extended reach capabilities. This feature is particularly beneficial in environments where access to tall or stacked goods is necessary, enhancing productivity by minimizing the need for additional equipment. The E32LH also maintains the core benefits of the E32 series, providing reliable performance with a strong focus on operator safety.

Shifting focus to the E36LB and E36LBH, these models cater to heavier lifting tasks. The E36 series incorporates enhanced lifting capacity and stability, essential for handling bulk materials or larger pallets. The robust build and powerful hydraulic systems offer improved performance in demanding applications, ensuring that heavy loads are transported safely and efficiently.

All models in the Desa E series are integrated with ergonomic features aimed at enhancing user comfort. This includes adjustable handles and controls that reduce operator fatigue during long shifts. Furthermore, safety features such as overload protection and anti-slip surfaces are standard, ensuring that operators can work confidently without compromising safety.

In terms of technology, the E series utilizes advanced engineering that emphasizes energy efficiency and low maintenance costs. The hydraulic systems are designed for longevity, and the overall construction of these machines is aimed at withstanding harsh industrial environments.

With a commitment to innovation and efficiency, the Desa E32L, E32LBH, E32LH, E36LB, and E36LBH models reflect modern advancements in material handling technology, making them invaluable assets for businesses seeking to optimize their operational productivity and safety.