Desa E36LH, E36LBH, E32LH, E32LBH Troubleshooting, Observed Problem Possible Cause Remedy

Page 14

Troubleshooting

Note: Before troubleshooting system, make sure power to circuit from breaker or fuse panel

is turned ON.

The three most common causes of a malfunctioning electric fireplace are:

1.Tripped circuit breaker or blown fuse.

2.Loose or burned out light bulb.

3.Obstructed or clogged fan blower.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

No operation or indicator light

1.

No power to fireplace

1.

Check circuit breaker or fuse

at power/heater switch

2.

Defective switch lamp

2.

Replace defective switch.

 

 

 

 

See Servicing Control Pan-

 

 

 

 

el, page 17

 

3.

Defective wiring

3.

Check connections from

 

 

 

 

main power harnesses to

 

 

 

 

terminals on control panel.

 

 

 

 

See Servicing Control Pan-

 

 

 

 

el, page 17

Poor flame motion; flame pat- tern is sporadic or uneven in viewing area

1.Tangled or loose flame pennants

2.Obstructed or clogged fan blower

3.Damaged or dislodged fan blower wheel

1.Inspect flame pennants. Un- tangle or replace if neces- sary. See Servicing Flame

Pennants, page 19

2.Check fan blower for de- bris. Vacuum areas around blower wheel and remove any obstructions. See Main- taining Motors, page 16

3.Remove and inspect fan blower housing See Servic- ing Fan Blower, page 19

Dull flame appearance or inac- 1.

Burned out or loose light

tive ember bed effect

bulb

2.

Broken lamp fixture

3.

Loose or missing reflective

 

ribbons

1.Inspect light bulbs; tighten or replace light bulbs as necessary. See Replacing

Light Bulbs, page 16

2.Remove and replace broken lamp fixture. See Replacing Lamp Fixtures, page 20

3.Inspect reflective ribbons. Reattach or replace as nec- essary. See Replacing Re- flective Ribbons, page 20

No heat or intermittent heat 1. Obstructed heater blower

1. Clear heater fan of debris

output. (If equipped with a

or blockage; vacuum area

heater)

around blower intake and

 

remove any obstructions

 

in the discharge area. See

 

Maintaining Motors, page 16

2. Burned out heat element

2. Remove and replace blower

or blower fan

heater assembly. To access

 

and remove see Optional

 

Heater Accessory, page

 

10

3. Defective heater switch or

3. Inspect wiring connections

wiring

from switch to blower. Re-

 

place switch if defective.

 

See Servicing Control Pan-

 

el, page 17

14

www.desatech.com

111076-01F

Image 14
Contents Electric Fireplace OWNER’S Operation and Installation Manual Table of Contents SafetyLocating Fireplace Product SpecificationInstallation Installation Clearances For mantel clearances see Figures 3BUILT-IN Installation Electrical InstallationRemoving Shipping Brace Features and Operation Lamps and lava RockAccessory Installation Optional Glass DoorsScrew Bifold doors may be removed for replacing or cleaningOptional Brick Liners Bracket Optional Heater AccessoryRetainer Mount location with on I indicator Wired for convenienceHarness Strap Mounting Screws Heater Blower Assembly Knockout Plug Remove to Install Power SwitchHeater Circuit Diagrams Remount harness strap to blower mount, if removedConnecting Heater Wires Terminal D Switch Jumper Terminal L-5 LeadTroubleshooting Observed Problem Possible Cause RemedyWiring Diagram Heater Assembly Electrical DiagramMaintaining Motors MaintenanceReplacing Light Bulbs Removing/Replacing Control DoorServicing Control Panel Accessing Imaging Unit Viewing ScreenServicing Flame Pennants Screw Fan Assembly Posts for Blade ConnectorsServicing Fan Blower Base CoverReplacing Lamp Fixtures Locating Flame PennantsReplacing Reflective Ribbons Replacing Fixtures Shown without FIrebox for ClarityRemove any loose or damaged ribbon material Cleaning Viewing ScreenAccessing Imaging Unit For Replacement Parts Under Warranty Technical ServiceReplacement Parts Parts Not Under WarrantyParts Parts KEY Description Bifold Glass Door Kits AccessoriesPerimeter Trim Kits Fixed Glass Door KitsLimited 1 Year Warranty WarrantyKeep this Warranty

E32LB, E36L, E36LH, E32L, E32LH specifications

The Desa E32L, E32LBH, E32LH, E36LB, and E36LBH are part of a versatile range of container handling equipment designed for efficient operations in various industrial environments. These models are particularly known for their robust performance, durability, and user-friendly features, making them suitable for both indoor and outdoor applications.

The Desa E32L and E32LBH are characterized by their compact designs, which allow for easy maneuverability in tight spaces. These models are equipped with advanced lifting technologies, including hydraulic systems that ensure smooth and precise lifting. The E32L model is specifically designed for lighter loads, making it ideal for warehouses and manufacturing settings where space is limited.

On the other hand, the E32LBH variant adds a height-adjustable feature, allowing operators to adapt to different working conditions without compromising stability. This flexibility makes it a favored choice in varied environments, including distribution centers where changes in load height are common.

The E32LH model stands out with its extended reach capabilities. This feature is particularly beneficial in environments where access to tall or stacked goods is necessary, enhancing productivity by minimizing the need for additional equipment. The E32LH also maintains the core benefits of the E32 series, providing reliable performance with a strong focus on operator safety.

Shifting focus to the E36LB and E36LBH, these models cater to heavier lifting tasks. The E36 series incorporates enhanced lifting capacity and stability, essential for handling bulk materials or larger pallets. The robust build and powerful hydraulic systems offer improved performance in demanding applications, ensuring that heavy loads are transported safely and efficiently.

All models in the Desa E series are integrated with ergonomic features aimed at enhancing user comfort. This includes adjustable handles and controls that reduce operator fatigue during long shifts. Furthermore, safety features such as overload protection and anti-slip surfaces are standard, ensuring that operators can work confidently without compromising safety.

In terms of technology, the E series utilizes advanced engineering that emphasizes energy efficiency and low maintenance costs. The hydraulic systems are designed for longevity, and the overall construction of these machines is aimed at withstanding harsh industrial environments.

With a commitment to innovation and efficiency, the Desa E32L, E32LBH, E32LH, E36LB, and E36LBH models reflect modern advancements in material handling technology, making them invaluable assets for businesses seeking to optimize their operational productivity and safety.