Desa (V)V42EPA(1) Fireplace Installation, Continued, Installing Log No, Ember Material

Page 23
Figure 41- Installing Log No. 2

FIREPLACE INSTALLATION

Installing Logs, Lava Rock, and Glowing Embers

23

FIREPLACE INSTALLATION

Continued

2.Rest left side of log #2 (front log) onto top of log #1. Place right side of log onto second pin located on right side of grate (see Figure 41).

3.Place log #3 (rear log) onto pins on rear of grate as shown in Figure 42.

4.Place log #4 (crossover log) onto pins from both logs #2 and #3 as shown in Figure 43.

5.Place log #5 (top log) onto right pin of front log (#2) and the smooth surface of crossover log (#4) as shown in Figure 44. Make sure it is seated properly.

6.Place log #6 (left log) onto left pin of front log (#2) and the smooth surface of rear log (#3) as shown in Figure 45. Make sure it is seated properly.

7.Place log #7 onto right pin of top log (#5) as shown in Figure 45. Make sure it is seated properly

8.Place lava rock along sides and front of firebox bottom in ar- eas that are visible only. It is not necessary to use all of the lava rock provided.

NOTICE: Do not put lava rock on burner or under burner. Placing lava rock on burner will cause perfor- mance problems.

9.Pull ember material apart into pieces no larger than a dime. Place these pieces loosely and sparingly directly onto the ex- posed section of the front burner and along the space between the burner and grate prongs (see Figure 46). This will create the glowing ember appearance as the flame touches the ember material. Do not block air slots by using too much ember ma- terial in one area. It is not necessary to use all of the ember material provided.

10.Close glass door, lock door latches, replace screen, and close louvers (see Removing/Replacing Glass Door, steps 5 through 7, page 21).

Figure 44 - Installing Log No. 5 WARNING: The glass door must be securely in place before running this fireplace. Do not run this fireplace if glass is missing or broken.

5

2

Figure 41- Installing Log No. 2

3

Figure 44 - Installing Log No. 5

6

7

 

4

Figure 45 - Installing Log No. 6 and Log No. 7

Figure 42 - Installing Log No. 3 Figure 43 - Installing Log No. 4

Ember Material
Figure 46 - Placing Ember Material on Burner

Figure 45 - Installing Log No. 6 and Log No. 7For moreEmber MaterialFigure 46 - Placing Ember Material on BurnerManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

111907-01A

Image 23
Contents Do not touch any electrical switch OWNER’S OPERATION AND INSTALLATION MANUALFOR YOUR SAFETY FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GASWARNINGS TABLE OF CONTENTSSAFETY INFORMATION SAFETY INFORMATION PRODUCT IDENTIFICATIONLOCAL CODES ContinuedLOCATION AND SPACE REQUIREMENTS PRODUCT FEATURESPRE-INSTALLATION PREPARATION Continued CLEARANCESFRAMING AND FINISHING PRE-INSTALLATION PREPARATIONLOCATION OF TERMINATION CAP LOCATION OF TERMINATION CAPD E B L V G V AINSTALLATION PRECAUTIONS VENTING INSTALLATION INSTRUCTIONSContinued INSTALLATION PLANNINGHorizontal Termination Installation VENTING INSTALLATION INSTRUCTIONSContinued VENTING INSTALLATION INSTRUCTIONSVENTING INSTALLATION INSTRUCTIONS Continued Horizontal Termination ConfigurationsVENTING INSTALLATION INSTRUCTIONS VENTING INSTALLATION INSTRUCTIONSRecommended Applications VENTING INSTALLATION INSTRUCTIONSContinued Venting with Two 90 Elbows VENTING INSTALLATION INSTRUCTIONSContinued Venting with Two 90 ElbowsContinued INSTALLATION FOR VERTICAL TERMINATIONFlat Ceiling Installation VENTING INSTALLATION INSTRUCTIONSVenting with Two 90 Elbows Vertical Termination ConfigurationsVENTING INSTALLATION INSTRUCTIONS ContinuedVertical Venting HIGH ALTITUDE INSTALLATIONVENTING INSTALLATION INSTRUCTIONS ContinuedModel BK Installation FIREPLACE INSTALLATIONINSTALLING OPTIONAL BLOWER ACCESSORY DESA Venting AccessoriesContinued FIREPLACE INSTALLATION8.Plug in blower power cord Continued Model BKT InstallationBlower Wiring Diagram FIREPLACE INSTALLATIONContinued INSTALLING GAS PIPING TO FIREPLACE LOCATIONFIREPLACE INSTALLATION CHECKING GAS CONNECTIONS CONNECTING FIREPLACE TO GAS SUPPLYInstallation Items Needed Pressure Testing Gas Supply Piping SystemREMOVING/REPLACING GLASS DOOR Pressure Testing Fireplace Gas ConnectionsCleaning Glass Door See Cleaning and Maintenance on pageContinued INSTALLING LOGS, LAVA ROCK AND GLOWING EMBERSFIREPLACE INSTALLATION Figure 44 - Installing Log No FIREPLACE INSTALLATIONFIREPLACE INSTALLATION Figure 41- Installing Log NoFIREPLACE INSTALLATION WIRING DIAGRAMWALL SWITCH INSTALLATION OPTIONAL REMOTE CONTROL INSTALLATION Model WRCTO TURN OFF GAS TO APPLIANCE FOR YOUR SAFETY READ BEFORE LIGHTINGOPERATING FIREPLACE LIGHTING INSTRUCTIONSBURNER FLAME PATTERN OPERATING OPTIONAL BLOWER ACCESSORYPILOT ASSEMBLY INSPECTING BURNERSLOGS CLEANING AND MAINTENANCEGLASS DOOR PILOT AND BURNERSREMEDY TROUBLESHOOTINGOBSERVED PROBLEM POSSIBLE CAUSEOBSERVED PROBLEM REMEDYing Gas Connections, pages 20 and TROUBLESHOOTINGModels VV42ENA1, VV42ENSA1, VV42ENHA1 ILLUSTRATED PARTS BREAKDOWNMODELS ILLUSTRATED PARTS BREAKDOWNPARTS LIST PARTS LISTILLUSTRATED PARTS BREAKDOWN BURNER ASSEMBLY FOR MODELS VV42ENA1, VV42ENSA1VV42ENHA1, VV42EPA1,3 VV42EPSA1, AND VV42EPHA1 NUMBER PARTS LISTPARTS LIST PARTSPECIFICATIONS REPLACEMENT PARTSSERVICE HINTS TECHNICAL SERVICEOWNERS REGISTRATION FORM TAPE TAPEPostage Required WALL MOUNTED ON/OFF SWITCH - GWMS2 Not Shown ACCESSORIESFLEXIBLE GAS LINE CONNECTOR - GA5081 REMOTE CONTROL KIT - WRC SERIES Not ShownWARRANTY INFORMATION LIMITED WARRANTY DIRECT-VENTFIREPLACENOT A UPC