Desa (V)V42ENA(1) Wiring Diagram, Wall Switch Installation, Fireplace Installation, Continued

Page 24
WALL SWITCH INSTALLATION

24

FIREPLACE INSTALLATION

Wall Switch Installation

Optional Remote Control Installation

WIRING DIAGRAM

FIREPLACE INSTALLATION

Continued

WALL SWITCH INSTALLATION

The installation of a wall switch allows you to activate the gas control valve and turn the fireplace on and off. The wall switch is to be connected to the incoming 120 volt regular household wiring that supplies the electricity to the fireplace. Refer to wiring diagram below.

OPTIONAL REMOTE CONTROL

INSTALLATION (Model WRC)

Note: If using optional wireless hand-held remote control, the wall switch must be in the ON position to be operational. The remote control then becomes the switching mechanism for fireplace operation.

1.Open lower louver panel.

2.The WRC model receiver does not require a battery. The re- ceiver can be installed by first plugging the short extension cord into the fireplace receptacle. Then plug the receiver unit into the extension cord. Finally plug the ignition module plug into the receiver unit (see Figure 47).

3.Activate the remote handset battery by removing the insulat- ing tab on the back of the handset (see Figure 48). The battery is included pre-installed.

4.Once the battery is activated the unit is ready to use.

5.Close lower louver panel.

Fireplace

Receptacle

Remote Control

Receiver

Extension Cord

Ignition

Module Plug

Figure 47 - Installing the WRC Remote Receiver

OPTIONAL REMOTE CONTROLBattery Cover

12 Volt Battery

Back of

Handset WIRING DIAGRAMPull to Remove

Insulation Tab

Figure 48 - Installing Battery into Back of Handset

WIRING DIAGRAM

INCOMING MAIN

GAS SUPPLY

EV1

EV2

GAS LINE TO

BURNER

Pilot

Burner

Pilot Gas

Line

MV

TH

PV/MV

TR

GND

PV

IGN

24V AC

STEP DOWN

TRANSFORMER

120V AC

WALL SWITCH (SUPPLIED)

ON

OFF

BLACK

INCOMING

 

WHITE

120V AC

GREEN

(FUSE BOX

OR BREAKER)

 

BLACK

WHITE

GREEN

ELECTRICAL RATING:

120v, 60Hz, 0.7A

OPTIONAL

REMOTE

CONTROL

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

111907-01A

Image 24
Contents OWNER’S OPERATION AND INSTALLATION MANUAL FOR YOUR SAFETYFOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS Do not touch any electrical switchTABLE OF CONTENTS SAFETY INFORMATIONWARNINGS PRODUCT IDENTIFICATION LOCAL CODESContinued SAFETY INFORMATIONPRODUCT FEATURES PRE-INSTALLATION PREPARATIONLOCATION AND SPACE REQUIREMENTS CLEARANCES FRAMING AND FINISHINGPRE-INSTALLATION PREPARATION ContinuedLOCATION OF TERMINATION CAP D E B LV G V A LOCATION OF TERMINATION CAPVENTING INSTALLATION INSTRUCTIONS INSTALLATION PRECAUTIONSINSTALLATION PLANNING Horizontal Termination InstallationVENTING INSTALLATION INSTRUCTIONS ContinuedVENTING INSTALLATION INSTRUCTIONS VENTING INSTALLATION INSTRUCTIONSContinued Horizontal Termination Configurations VENTING INSTALLATION INSTRUCTIONSVENTING INSTALLATION INSTRUCTIONS ContinuedVENTING INSTALLATION INSTRUCTIONS ContinuedRecommended Applications VENTING INSTALLATION INSTRUCTIONS ContinuedVenting with Two 90 Elbows Venting with Two 90 ElbowsINSTALLATION FOR VERTICAL TERMINATION Flat Ceiling InstallationVENTING INSTALLATION INSTRUCTIONS ContinuedVertical Termination Configurations VENTING INSTALLATION INSTRUCTIONSContinued Venting with Two 90 ElbowsHIGH ALTITUDE INSTALLATION VENTING INSTALLATION INSTRUCTIONSContinued Vertical VentingFIREPLACE INSTALLATION INSTALLING OPTIONAL BLOWER ACCESSORYDESA Venting Accessories Model BK InstallationFIREPLACE INSTALLATION 8.Plug in blower power cordContinued Model BKT Installation Blower Wiring DiagramFIREPLACE INSTALLATION ContinuedINSTALLING GAS PIPING TO FIREPLACE LOCATION FIREPLACE INSTALLATIONContinued CONNECTING FIREPLACE TO GAS SUPPLY Installation Items NeededPressure Testing Gas Supply Piping System CHECKING GAS CONNECTIONSPressure Testing Fireplace Gas Connections Cleaning Glass DoorSee Cleaning and Maintenance on page REMOVING/REPLACING GLASS DOORINSTALLING LOGS, LAVA ROCK AND GLOWING EMBERS FIREPLACE INSTALLATIONContinued FIREPLACE INSTALLATION FIREPLACE INSTALLATIONFigure 41- Installing Log No Figure 44 - Installing Log NoWIRING DIAGRAM WALL SWITCH INSTALLATIONOPTIONAL REMOTE CONTROL INSTALLATION Model WRC FIREPLACE INSTALLATIONFOR YOUR SAFETY READ BEFORE LIGHTING OPERATING FIREPLACELIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCEOPERATING OPTIONAL BLOWER ACCESSORY PILOT ASSEMBLYINSPECTING BURNERS BURNER FLAME PATTERNCLEANING AND MAINTENANCE GLASS DOORPILOT AND BURNERS LOGSTROUBLESHOOTING OBSERVED PROBLEMPOSSIBLE CAUSE REMEDYREMEDY ing Gas Connections, pages 20 andTROUBLESHOOTING OBSERVED PROBLEMILLUSTRATED PARTS BREAKDOWN MODELSILLUSTRATED PARTS BREAKDOWN Models VV42ENA1, VV42ENSA1, VV42ENHA1PARTS LIST PARTS LISTBURNER ASSEMBLY FOR MODELS VV42ENA1, VV42ENSA1 VV42ENHA1, VV42EPA1,3 VV42EPSA1, AND VV42EPHA1ILLUSTRATED PARTS BREAKDOWN PARTS LIST PARTS LISTPART NUMBERREPLACEMENT PARTS SERVICE HINTSTECHNICAL SERVICE SPECIFICATIONSOWNERS REGISTRATION FORM TAPE Postage RequiredTAPE ACCESSORIES FLEXIBLE GAS LINE CONNECTOR - GA5081REMOTE CONTROL KIT - WRC SERIES Not Shown WALL MOUNTED ON/OFF SWITCH - GWMS2 Not ShownLIMITED WARRANTY DIRECT-VENTFIREPLACE NOT A UPCWARRANTY INFORMATION