Desa (V)T32P, (V)T36P SERIES Replacement Parts, Service Hints, Technical Service, Specifications

Page 30

Replacement Parts

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

Parts Under Warranty

Contact authorized retailers of this product. If they can not supply original replacement part(s), call DESA’s Customer Service Depart- ment at 1-866-672-6040.

When calling DESA, have ready

your name

your address

model and serial numbers of your fireplace

how fireplace was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

Parts Not Under Warranty

Contact authorized retailers of this product. If they can not supply original replacement part(s), call DESA at 1-866-672-6040 for referral information.

When calling DESA, have ready

model number of your fireplace

the replacement part number

Service Hints

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

fireplace will not produce specified heat

propane/LP gas supply might be low (propane/LP units only)

You may feel your gas pressure is too low. If so, contact your local gas supplier.

Technical Service

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA’s Customer Service Depart- ment at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready.

You can also visit DESA’s technical service web site at www.desatech.com.

Specifications

 

 

CHDV32NR

 

CTDV36NR

 

 

 

 

Btu

 

(V)T32N(R)

 

(V)T36N(R)

 

(V)T32P(R)

 

(V)T36P(R)

12,000/18,000 Btu/hr

18,000/26,000 Btu/hr

11,000/17,000 Btu/hr

17,000/24,000 Btu/hr

Gas Type

 

Natural

 

Natural

 

Propane/LP

 

Propane/LP

Ignition

 

Piezo

 

Piezo

 

Piezo

 

Piezo

Manifold Pressure

 

3.5" w.c.

 

3.5" w.c.

 

10.0" w.c.

 

10.0" w.c.

Minimum Inlet Supply Pressure

 

5.5" w.c.

 

5.5" w.c.

 

11.0" w.c.

 

11.0" w.c.

Dimension, Inches/mm (HxWxD)

 

 

 

 

 

 

 

 

Fireplace (Actual size of

32

1/4" x 34 1/2" x 16

5/8"

36" x 41" x 21 1/8"

32

1/4" x 34 1/2" x 16

5/8"

36" x 41" x 21 1/8"

firebox. Measurements do not

include nailing flanges or

81.9 x 87.6 x 42.2 cm

91.4 x 104.1 x 53.7 cm

81.9 x 87.6 x 42.2 cm

91.4 x 104.1 x 53.7 cm

standoffs).

 

 

 

 

 

 

 

 

Carton

33

1/2" x 37 1/2" x 17

1/2"

38" x 44" x 22"

33

1/2" x 37 1/2" x 17

1/2"

38" x 44" x 22"

Weight, lbs/kg*

85.1 x 95.3 x 44.5 cm

96.5 x 111.8 x 55.9 cm

85.1 x 95.3 x 44.5 cm

96.5 x 111.8 x 55.9 cm

 

80 lbs/36 kg

 

120 lbs/55 kg

 

80 lbs/36 kg

 

120 lbs/55 kg

Fireplace

 

 

 

 

Shipping

 

83 lbs/38 kg

 

123 lbs/56 kg

 

83 lbs/38 kg

 

123 lbs/56 kg

*For refractory lined models add 45 pounds for 32" models and 60 pounds for 36" models.

30

www.desatech.com

108661-01F

Image 30
Contents For Your Safety What to do if YOU Smell GASTable of Contents Safety InformationProduct Features Product Identification Local CodesPre-Installation Preparation Location and space requirementsClearances Framing and finishing 23 1Location of Termination Cap Termination CAP AIR Supply Inlet GAS MeterInstallation Planning Venting Installation InstructionsInstallation Precautions Horizontal Termination InstallationVent Pipe Connections Installing Siding Standoff Horizontal Termination Configurations Square TerminationSnorkel Termination Installation Venting with Two 90 ElbowsFlat Ceiling Installation Offset with Wall Strap and 45 ElbowsVertical Termination Configurations Vertical VentingParts lists for venting kits and components Fireplace InstallationHigh Altitude Installation Installing optional blower accessoriesModel BKT Installation Blower Model BKInstalling Gas Piping to Fireplace Location Blower Wiring DiagramInstallation Items Needed Connecting Fireplace to GAS Supply Installation Items NeededChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Test Pressures In Excess Of 1/2 Psig 3.5 kPaInstalling Remote Receiver Attaching Alkaline Battery to ReceiverRemoving Louver Panels Cleaning Glass DoorRemoving/Replacing Glass Door Removing Glass DoorInstalling logs, lava rock and glowing embers Installing Log NoInstalling Logs No and No Operating Fireplace For your safety read Before lightingManual Lighting Procedure Lighting InstructionsThermostat Series Model HRC200 OpTIONAL Hand-HeldRemote Operation On/Off Series Model HRC100Inspecting Burners Operating optional blower accessoryPilot assembly Operating optional GWMT1 Wall Mounted ThermostatPilot and burners Cleaning MaintenanceGlass Door LogsTroubleshooting To clean pilot. This can damage pilot unitTroubleshooting Gas leak. See Warning statement AboveTechnical Service Replacement PartsService Hints SpecificationsAccessories Illustrated Parts Breakdown CHDV32NRParts List CTDV36NR Parts List Warranty Information Keep this Warrant