Desa (V)VC36N Series Installing GAS Piping to Fireplace Location, Installation Items Needed

Page 19

FIREPLACE INSTALLATION

Installing Gas Piping to Fireplace Location

19

FIREPLACE INSTALLATION

Continued

INSTALLING GAS PIPING TO FIREPLACE LOCATION

WARNING: A qualified service person must con- nect fireplace to gas supply. Follow all local codes.

CAUTION: For propane/LP units, never connect fireplace directly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator between the fireplace and propane/LP supply.

Installation Items Needed

Before installing fireplace, make sure you have the items listed below.

external regulator (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

approved flexible gas line with gas connector (if allowed by lo- cal codes)

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the CSA design-certified equipment shutoff valve from your retailer.

For propane/LP connection only, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, fireplace regulator damage could occur. Install external regulator

CAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diam- eter or greater to allow proper gas volume to fireplace. If pipe is too small, undue loss of volume will occur.

Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 31).

IMPORTANT: Install main gas valve (equipment shutoff valve) in an accessible location. The main gas valve is for turning on or shutting off the gas to the appliance.

Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.

WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

We recommend that you install a sediment trap/drip leg in supply line as shown in Figure 31. Locate sediment trap/drip leg where it is within reach for cleaning. Install in piping system between fuel supply and fireplace. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace gas con- trols. If sediment trap/drip leg is not installed or is installed wrong, fireplace may not run properly.

CSA Design-Certified

Equipment Shutoff Valve

with 1/8" NPT Tap*

with the vent pointing down as shown in Figure 30. Pointing the vent down protects it from freezing rain or sleet.

External

Propane/LP

Regulator

Supply Tank

Approved Flexible

Gas Line

3" Minimum

Natural - From Gas Meter (5.5" W.C. to 10.5"

W.C. Pressure)

Propane/LP From External Regulator (11" W.C. to 14" W.C. Pressure)

Vent

Pointing

Down

Cap Pipe Nipple Tee Joint

Figure 31 - Gas Connection

Sediment Trap/Drip Leg

Figure 30 - External Regulator with Vent Pointing Down (Propane/LP Only)

*The CSA design-certified equipment shutoff valve may be sup- plied with the appliance or you can purchase it from your retailer.

For morevisit www..com

108661-01E

Image 19
Contents For Your Safety What to do if YOU Smell GAS For Your SafetySafety Information Table of ContentsLocal Codes Safety Information Product IdentificationPRE-INSTALLATION Preparation Product FeaturesLocation and Space Requirements Framing and Finishing ClearancesBalcony with Perpendicular Side Wall Location of Termination CAPHorizontal Termination Installation Venting Installation InstructionsInstallation Precautions Installation PlanningVent Pipe Connections Installing Horizontal Vent Cap Series 29 min Horizontal Termination ConfigurationsSquare Termination VerticalCorner and Alternate Installation Venting with Two 90 Elbows Horizontal System Installation Using TWO 90 ElbowsFlat Ceiling Installation Installation for Vertical TerminationVenting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting High Altitude InstallationCheck GAS Type Fireplace InstallationParts Lists for Venting Kits and Components Installing Optional Blower AccessoriesAttaching Speed Control to Firebox Model BKT InstallationBlower Model BKT Blower Wiring DiagramInstallation Items Needed Installing GAS Piping to Fireplace LocationChecking GAS Connections Connecting Fireplace to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemInstalling Remote Receiver Pressure Testing Fireplace Gas ConnectionsRemoving Glass Door Cleaning Glass DoorREMOVING/REPLACING Glass Door Removing Louver PanelsInstalling Log No Installing LOGS, Lava Rock and Glowing EmbersInstalling Logs No and No Lighting Instructions For Your Safety Read Before LightingManual Lighting Procedure Operating FireplaceGhrc Series Operation Optional Remote OperationGhrcta Series Operation Operating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementSpecifications Replacement PartsService Hints Technical ServiceAccessories VT32NRB Illustrated Parts BreakdownVT32PRB CHDV32NR KEY Part Number Description QTY Parts ListCTDV36NR Not a field Warranty Information

(V)VC36N Series specifications

The Desa (V)VC36N Series is a versatile and sophisticated line of heating solutions designed to provide optimal comfort and energy efficiency. This series is engineered with cutting-edge technology, offering a range of features that cater to diverse heating needs, making it an ideal choice for residential and commercial applications.

One of the standout features of the VC36N Series is its impressive heating capacity. With a robust output, these units can effectively warm large spaces, ensuring a cozy environment during the colder months. The efficient heat distribution system optimizes warmth throughout the area, eliminating cold spots and enhancing overall comfort.

Additionally, the VC36N Series incorporates advanced burner technology, which not only contributes to its efficiency but also minimizes emissions. This eco-friendly design helps in reducing the carbon footprint, making it a responsible choice for environmentally conscious consumers. The burners are also engineered for longevity, ensuring reduced maintenance needs over the lifespan of the unit.

Another significant characteristic of the VC36N Series is its user-friendly controls. The intuitive interface allows for easy adjustments of temperature and settings, making it accessible for users of all experience levels. Some models even support remote access, enabling users to manage heating preferences from their smartphones or tablets, thereby enhancing convenience.

Moreover, the design of the VC36N Series emphasizes durability and aesthetic appeal. Constructed with high-quality materials, these units are built to withstand the rigors of daily use while maintaining a sleek and modern look that complements various interior styles.

Safety features are also paramount in the VC36N Series, with integrated systems designed to ensure safe operation. These include flame sensing technology and automatic shut-off mechanisms, providing peace of mind for users.

In summary, the Desa (V)VC36N Series stands out as a premium choice in heating solutions. With its powerful performance, energy-efficient technologies, user-friendly features, durable construction, and robust safety measures, it exemplifies quality and reliability, making it suitable for a wide range of applications. Whether for home use or in commercial settings, the VC36N Series is engineered to meet the demands of modern heating while prioritizing environmental sustainability and user comfort.