Desa (V)VC36N Series Location of Termination CAP, Balcony with Perpendicular Side Wall

Page 6

6

LOCATION OF TERMINATION CAP

LOCATION OF TERMINATION CAP

N

N

D

E V

B L

C

Fixed

 

V

Closed

 

 

 

Openable

 

F V

Openable

B

Fixed

Closed

H

V

B

I

G

B

B

V J X

G

A

M

V

K X

V

G V A

V TERMINATION CAP

X AIR SUPPLY INLET

G

GAS METER

RESTRICTED AREA (TERMINATION PROHIBITED)

A= clearance above grade, veranda, porch, deck, or balcony [*12 inches (305mm) minimum]

B= clearance to window or door that may be opened

[12 inches (305mm) minimum]

C = clearance to permanently closed window [minimum 12 inches (305mm) recommended to prevent condensation on window]

D = vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 24 inches (610mm) from the center-line of the terminal [18 inches (457mm) minimum]

E= clearance to unventilated soffit [12 inches (305mm) minimum]

F= clearance to outside corner (see below)

G= clearance to inside corner (see below)

H= *not to be installed above a meter/regulator assembly within

36 inches (914mm) horizontally from the center-line of the regulator

I= clearance to service regulator vent outlet [*72 inches (1829mm) minimum]

J= clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other fireplace [*12 inches (305mm) minimum]

K= clearance to a mechanical air supply inlet [*72 inches (1829mm) minimum]

L= † clearance above paved side-walk or a paved driveway located on public property [*84 inches (2133mm) minimum]

M= clearance under veranda, porch, deck [*12 inches (305mm) minimum ‡]

N= clearance above a roof shall extend a minimum of 24 inches (610mm) above the highest point when it passes through the roof surface and any other obstruction within a horizontal distance of 18 inches (457mm)

† vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings*

only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor* * as specified in CAN/CSA B149 (.1 or .2) Installation Codes (1991) for Canada and U.S.A.

Note: Local codes or regulations may require different clearances

Termination Clearances for Buildings with Combustible and Noncombustible Exteriors

Inside Corner

Outside Corner

A

 

 

 

A = 6" (152mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V

 

 

 

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B B = 6" (152mm)

Recessed Location

D

C

C

E

V

Balcony with No Side Wall

G

V

G = 12" (305mm) minimum clearance

Balcony with Perpendicular Side Wall

H

V

J

Combustible &

Noncombustible

H = 24" (610mm)

J = 20" (508mm)

C = Maximum depth of 48" (1219mm) for recessed location

D = Minimum width for back wall of recessed location - Combustible - 38" (965mm) Noncombustible - 24" (610mm)

E = Clearance from corner in recessed location- Combustible - 6" (152mm) Noncombustible - 2" (51mm)

Figure 7 - Minimum Clearances for Termination Cap

For..com

108661-01E

Image 6
Contents For Your Safety For Your Safety What to do if YOU Smell GASTable of Contents Safety InformationSafety Information Product Identification Local CodesProduct Features PRE-INSTALLATION PreparationLocation and Space Requirements Clearances Framing and FinishingLocation of Termination CAP Balcony with Perpendicular Side WallInstallation Planning Venting Installation InstructionsInstallation Precautions Horizontal Termination InstallationVent Pipe Connections Installing Horizontal Vent Cap Vertical Horizontal Termination ConfigurationsSquare Termination Series 29 minCorner and Alternate Installation Horizontal System Installation Using TWO 90 Elbows Venting with Two 90 ElbowsInstallation for Vertical Termination Flat Ceiling InstallationVertical Termination Configurations Venting with One 90 ElbowHigh Altitude Installation Vertical VentingInstalling Optional Blower Accessories Fireplace InstallationParts Lists for Venting Kits and Components Check GAS TypeModel BKT Installation Attaching Speed Control to FireboxBlower Wiring Diagram Blower Model BKTInstalling GAS Piping to Fireplace Location Installation Items NeededPressure Testing Gas Supply Piping System Connecting Fireplace to GAS SupplyInstallation Items Needed Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Installing Remote ReceiverRemoving Louver Panels Cleaning Glass DoorREMOVING/REPLACING Glass Door Removing Glass DoorInstalling LOGS, Lava Rock and Glowing Embers Installing Log NoInstalling Logs No and No Operating Fireplace For Your Safety Read Before LightingManual Lighting Procedure Lighting InstructionsOptional Remote Operation Ghrc Series OperationGhrcta Series Operation Inspecting Burners Operating Optional Blower AccessoryPilot Assembly Operating Optional GWMT1 Wall Mounted ThermostatPilot and Burners Cleaning MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement AboveTechnical Service Replacement PartsService Hints SpecificationsAccessories Illustrated Parts Breakdown VT32NRBVT32PRB CHDV32NR Parts List KEY Part Number Description QTYCTDV36NR Not a field Warranty Information

(V)VC36N Series specifications

The Desa (V)VC36N Series is a versatile and sophisticated line of heating solutions designed to provide optimal comfort and energy efficiency. This series is engineered with cutting-edge technology, offering a range of features that cater to diverse heating needs, making it an ideal choice for residential and commercial applications.

One of the standout features of the VC36N Series is its impressive heating capacity. With a robust output, these units can effectively warm large spaces, ensuring a cozy environment during the colder months. The efficient heat distribution system optimizes warmth throughout the area, eliminating cold spots and enhancing overall comfort.

Additionally, the VC36N Series incorporates advanced burner technology, which not only contributes to its efficiency but also minimizes emissions. This eco-friendly design helps in reducing the carbon footprint, making it a responsible choice for environmentally conscious consumers. The burners are also engineered for longevity, ensuring reduced maintenance needs over the lifespan of the unit.

Another significant characteristic of the VC36N Series is its user-friendly controls. The intuitive interface allows for easy adjustments of temperature and settings, making it accessible for users of all experience levels. Some models even support remote access, enabling users to manage heating preferences from their smartphones or tablets, thereby enhancing convenience.

Moreover, the design of the VC36N Series emphasizes durability and aesthetic appeal. Constructed with high-quality materials, these units are built to withstand the rigors of daily use while maintaining a sleek and modern look that complements various interior styles.

Safety features are also paramount in the VC36N Series, with integrated systems designed to ensure safe operation. These include flame sensing technology and automatic shut-off mechanisms, providing peace of mind for users.

In summary, the Desa (V)VC36N Series stands out as a premium choice in heating solutions. With its powerful performance, energy-efficient technologies, user-friendly features, durable construction, and robust safety measures, it exemplifies quality and reliability, making it suitable for a wide range of applications. Whether for home use or in commercial settings, the VC36N Series is engineered to meet the demands of modern heating while prioritizing environmental sustainability and user comfort.