Desa (V)VC36N Series installation manual Safety Information Product Identification, Local Codes

Page 3

SAFETY INFORMATION PRODUCT IDENTIFICATION LOCAL CODES

3

SAFETY INFORMATION

Continued

PRODUCT IDENTIFICATION

5.

This fireplace reaches high temperatures. Keep children and

 

adults away from hot surfaces to avoid burns or clothing igni-

 

tion. Fireplace will remain hot for a time after shutdown. Al-

 

low surfaces to cool before touching.

6.

Carefully supervise young children when they are in the room

 

with fireplace.

7.

Do not modify this fireplace under any circumstances. Any

 

parts removed for servicing must be replaced prior to operat-

 

ing fireplace.

8.

Turn fireplace off and let cool before servicing, installing, or

 

repairing. Only a qualified service person should install, ser-

 

vice, or repair this fireplace. Have fireplace inspected annu-

 

ally by a qualified service person.

9.

You must keep control compartments, burners, and circulat-

 

ing air passages clean. More frequent cleaning may be needed

 

due to excessive lint and dust from carpeting, bedding mate-

 

rial, etc. Turn off the gas valve and pilot light before cleaning

 

fireplace.

10.

Have venting system inspected annually by a qualified service

 

person. If needed, have venting system cleaned or repaired.

 

See Cleaning and Maintenance, page 28.

11.

Keep the area around your fireplace clear of combustible ma-

 

terials, gasoline, and other flammable vapor and liquids. Do

 

not run fireplace where these are used or stored. Do not place

 

items such as clothing or decorations on or around fireplace.

12.

Do not use this fireplace to cook food or burn paper or other

Upper Louver

Panel

Nailing

Flange

Glass

Door

Assembly

Piezo

Ignitor

Control

Valve

Lower

Louver Glowing

Panel Embers

ON/OFF/REMOTE Switch

(Optional Installation)

Flue Collar

Log

Set

Lava

Rock

Grate

Assembly

Blower Switch (Optional Installation)

 

objects.

13.

Do not use any solid fuels (wood, coal, paper, cardboard, etc.)

 

in this fireplace. Use only the gas type indicated on fireplace

 

nameplate.

14.

This appliance, when installed, must be electrically grounded

 

in accordance with local codes or, in the absence of local codes,

 

with the National Electrical Code, ANSI/NFPA 70, or the Ca-

 

nadian Electrical Code, CSA C22.1.

15.

Do not use fireplace if any part has been exposed to or under

 

water. Immediately call a qualified service person to arrange

 

for replacement of the unit.

16.

Do not operate fireplace if any log is broken.

17.

Do not use a blower insert, heat exchanger insert, or other ac-

 

cessory not approved for use with this fireplace.

18.

Do not operate fireplace with glass door removed, cracked, or

 

broken.

19.

Provide adequate clearances around air openings.

Figure 1 - Tudor Direct-Vent Fireplace with Millivolt Ignition

LOCAL CODES

Install and use fireplace with care. Follow all local codes. In the absence to local codes, use the current National Fuel Gas Code ANSI Z223.1/NFPA 54* (USA) or the current CSA-B149.1 Instal- lation Code (Canada).

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

For morevisit www..com

108661-01E

Image 3
Contents For Your Safety What to do if YOU Smell GAS For Your SafetySafety Information Table of ContentsLocal Codes Safety Information Product IdentificationProduct Features PRE-INSTALLATION PreparationLocation and Space Requirements Framing and Finishing ClearancesBalcony with Perpendicular Side Wall Location of Termination CAPHorizontal Termination Installation Venting Installation InstructionsInstallation Precautions Installation PlanningVent Pipe Connections Installing Horizontal Vent Cap Series 29 min Horizontal Termination ConfigurationsSquare Termination VerticalCorner and Alternate Installation Venting with Two 90 Elbows Horizontal System Installation Using TWO 90 ElbowsFlat Ceiling Installation Installation for Vertical TerminationVenting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting High Altitude InstallationCheck GAS Type Fireplace InstallationParts Lists for Venting Kits and Components Installing Optional Blower AccessoriesAttaching Speed Control to Firebox Model BKT InstallationBlower Model BKT Blower Wiring DiagramInstallation Items Needed Installing GAS Piping to Fireplace LocationChecking GAS Connections Connecting Fireplace to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemInstalling Remote Receiver Pressure Testing Fireplace Gas ConnectionsRemoving Glass Door Cleaning Glass DoorREMOVING/REPLACING Glass Door Removing Louver PanelsInstalling Log No Installing LOGS, Lava Rock and Glowing EmbersInstalling Logs No and No Lighting Instructions For Your Safety Read Before LightingManual Lighting Procedure Operating FireplaceOptional Remote Operation Ghrc Series OperationGhrcta Series Operation Operating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementSpecifications Replacement PartsService Hints Technical ServiceAccessories Illustrated Parts Breakdown VT32NRBVT32PRB CHDV32NR KEY Part Number Description QTY Parts ListCTDV36NR Not a field Warranty Information

(V)VC36N Series specifications

The Desa (V)VC36N Series is a versatile and sophisticated line of heating solutions designed to provide optimal comfort and energy efficiency. This series is engineered with cutting-edge technology, offering a range of features that cater to diverse heating needs, making it an ideal choice for residential and commercial applications.

One of the standout features of the VC36N Series is its impressive heating capacity. With a robust output, these units can effectively warm large spaces, ensuring a cozy environment during the colder months. The efficient heat distribution system optimizes warmth throughout the area, eliminating cold spots and enhancing overall comfort.

Additionally, the VC36N Series incorporates advanced burner technology, which not only contributes to its efficiency but also minimizes emissions. This eco-friendly design helps in reducing the carbon footprint, making it a responsible choice for environmentally conscious consumers. The burners are also engineered for longevity, ensuring reduced maintenance needs over the lifespan of the unit.

Another significant characteristic of the VC36N Series is its user-friendly controls. The intuitive interface allows for easy adjustments of temperature and settings, making it accessible for users of all experience levels. Some models even support remote access, enabling users to manage heating preferences from their smartphones or tablets, thereby enhancing convenience.

Moreover, the design of the VC36N Series emphasizes durability and aesthetic appeal. Constructed with high-quality materials, these units are built to withstand the rigors of daily use while maintaining a sleek and modern look that complements various interior styles.

Safety features are also paramount in the VC36N Series, with integrated systems designed to ensure safe operation. These include flame sensing technology and automatic shut-off mechanisms, providing peace of mind for users.

In summary, the Desa (V)VC36N Series stands out as a premium choice in heating solutions. With its powerful performance, energy-efficient technologies, user-friendly features, durable construction, and robust safety measures, it exemplifies quality and reliability, making it suitable for a wide range of applications. Whether for home use or in commercial settings, the VC36N Series is engineered to meet the demands of modern heating while prioritizing environmental sustainability and user comfort.