8.Insert the 4 wire harness into one of the round holes in the rear of the blower control shield and through the rectangular hole in the front of shield (see Figure 16).

9.Reconnect red wire to the AUTO switch posi- tion. Reconnect blue wire to the ON switch position. Reconnect green and white wires to the power cord.

10.Install the switch plate on the blower control shield with 2 - #10 screws provided (see Fig-

ure 17). Route power cord out of the cabinet by inserting it through the bushing on the outer casing (see Figure 16). Plug fan kit into 120-Volt grounded power supply and test operation. Note: When switch is in the AUTO position, the fan will start after the heater has run for a few moments. The fan will continue to run for several moments after the heater has been turned off. When switch is in the ON position, the fan will run until turned to OFF. Reinstall hood assembly and close lower louver door.

Wiring Routing Hole

Blower Bracket

Assembly

Screw

Heat Deflector

Switch

 

 

Wire Harness

 

Power

 

Cord

 

Red

Blue

 

Switch Plate

Wire

 

 

Harness

Blower

 

Control

 

Shield

 

Shield Cover

Figure 16 - Installing Blower Bracket Assembly

Blower Control

Shield

Switch Plate Screw Figure 17 - Installing Switch Plate to Blower Control Shield

113896-01B

www.desatech.com

13

Image 13
Contents What to do if YOU Smell GAS Table of Contents Safety Information Unpacking Local CodesSafety Pilot Product FeaturesProduct Identification Piezo Ignition SystemDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationUnusually Tight Construction Confined and Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationLocating Fireplace Rough Opening for Installing Wall BUILT-IN Fireplace InstallationAttaching Fireplace to Wall Studs Mantel Clearances for Built-In InstallationRemoving Brick Liner Retainer Optional Mantel InstallationAssembling Trim Trim shipped with mantelRemoving Hood Installing Blower Assembly GA3450TInstalling Blower Bracket Assembly For Built-In Installation Installation Items Needed Connecting to GAS SupplyPropane/LP Connecting Fireplace to GAS SupplyNatural From Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures In Excess Of 1/2 Psig KPaPressure Testing Heater GAS Connections Installing LogsOperating Fireplace For Your Safety Read Before LightingLighting Instructions Inspecting Burners Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationBurner Flame Pattern Cleaning MaintenanceBurner Primary AIR Holes Main BurnerBlow air into the primary air holes on the injector holder CabinetObserved Problem Possible Cause Remedy TroubleshootingSee Cleaning and Mainte On windows Tilation air Gas leak. See Warning Replacement Parts SpecificationsService Hints Technical ServiceModels CF26PTA and CF26NTA Illustrated Parts BreakdownParts List 20-1 11-1 20-3 11-2 KEY Part Number Description QTY Accessories Cabinet Mantel with Full Hearth Base Cleaning KIT GCKInformation Video Not ShownParts Central 113896-01B Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS BAY Front Fireplace

CF26NTA specifications

Desa CF26NTA is a highly versatile and innovative diesel generator designed to meet the power needs of various applications. With its robust construction and efficient performance, the CF26NTA serves as an ideal power solution for both residential and commercial use, particularly in regions where grid power is unreliable or unavailable.

One of the main features of the Desa CF26NTA is its powerful 26 kVA output, which provides ample energy to support multiple appliances and systems simultaneously. This generator is capable of handling the demands of larger homes, construction sites, and outdoor events, ensuring that essential functions are maintained even during power outages.

The CF26NTA utilizes advanced technology to provide reliable power while minimizing fuel consumption and emissions. Equipped with a high-efficiency diesel engine, this generator offers extended run times and an impressive fuel economy, making it a cost-effective choice for long-term power needs. The engine complies with stringent environmental regulations, ensuring that users can operate it with confidence regarding its impact on the environment.

Another notable characteristic of the Desa CF26NTA is its user-friendly control panel, which features easy-to-read gauges and indicators. This design allows operators to monitor essential parameters such as voltage, frequency, and fuel levels at a glance, facilitating efficient management of the generator's operation. Additionally, the generator is fitted with automatic voltage regulation (AVR) technology, providing stable power output and protecting connected devices from voltage fluctuations.

Portability is an essential aspect of the CF26NTA, as it is designed with a compact frame and integrated wheels for easy transportation. Whether moving it between job sites or relocating for outdoor events, users will appreciate the generator's ease of mobility without compromising its stability during operation.

The Desa CF26NTA is built to withstand the rigors of demanding environments. It features weather-resistant casing and a durable design that ensures longevity and dependability even in challenging conditions. Furthermore, its maintenance-friendly layout allows for easy access to key components, simplifying routine servicing and upkeep.

In summary, the Desa CF26NTA stands out with its robust power output, efficient diesel engine technology, user-friendly features, and portable design. It is an excellent choice for anyone in need of a reliable generator that combines performance with convenience, making it suitable for various applications, from home use to commercial settings.