Desa CF26NTA BUILT-IN Fireplace Installation, Rough Opening for Installing Wall

Page 9

INSTALLATION

Continued

An optional blower kit is available from your dealer. See Accessories, page 32. If planning to use blower, locate fireplace near an electrical outlet.

Note: When installing fireplace directly on carpet- ing, tile or other combustible material, other than wood flooring, the fireplace shall be installed on a metal or wood panel extending the full width and depth of the fireplace.

CEILING

 

42" Minimum

6"

 

Minimum

 

From

 

Sides Of

 

Fireplace

 

Left

Right

Side

Side

FLOOR

0" Minimum Clearance To Top Surface Of Carpeting, Tile Or Other Combustible Material

Figure 4 - Mounting Clearances As

Viewed From Front of Fireplace Shown

Built In The Wall

CEILING

42"

Top OfMinimum Mantel Can

Be Flush

With Wall

 

Right

Left

Side

 

Side

 

0" Minimum Clearance To Top Surface Of Carpeting, Tile Or Other Combustible Material

Figure 5 - Mounting Clearances As

Viewed From Front of Fireplace Shown

with Optional Mantel

BUILT-IN FIREPLACE

INSTALLATION

Built-in installation of this fireplace involves in- stalling fireplace into a framed-in enclosure. This makes the front of fireplace flush with wall. Follow the instructions below to install the fireplace in this manner. If installing a built-in mantel above the fireplace, you must follow the clearances shown in Figure 9, page 11. If using for built-in instal- lation off of the floor, follow clearances shown in Figure 4.

 

Actual

Framing

Height

26"

26 7/8"

Front Width

26 3/4"

26 7/8"

Depth

9 1/2"

10 1/2"

Bottom

3/4"

3/4"

1.Frame in rough opening. Use dimensions shown in Figure 6 for the rough opening.

If installing in a corner, use dimensions shown in Figure 7 for the rough opening. The height is 26 1/8" which is the same as the wall opening above.

2.An optional blower accessory is available (see Accessories, page 32). There are two options for connecting blower to electrical source.

Option one: Have a licensed electrician install a properly grounded, three-prong 120-volt electrical outlet at fireplace location. Locate outlet inside the framed enclosure. Blower power cord will plug into this outlet.

101/2"

267/8"

3/4" Off

The Floor

267/8" Minimum

Figure 6 - Rough Opening for Installing

in Wall

365/8"

257/8"

267/8" 513/4"

Figure 7 - Rough Opening for Installing

in Corner

113896-01B

www.desatech.com

9

Image 9
Contents What to do if YOU Smell GAS Table of Contents Safety Information Unpacking Local CodesSafety Pilot Product FeaturesProduct Identification Piezo Ignition SystemDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationUnusually Tight Construction Confined and Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Check GAS TypeLocating Fireplace Rough Opening for Installing Wall BUILT-IN Fireplace InstallationAttaching Fireplace to Wall Studs Mantel Clearances for Built-In InstallationRemoving Brick Liner Retainer Optional Mantel InstallationAssembling Trim Trim shipped with mantelRemoving Hood Installing Blower Assembly GA3450TInstalling Blower Bracket Assembly For Built-In Installation Installation Items Needed Connecting to GAS SupplyConnecting Fireplace to GAS Supply Propane/LPNatural From Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures In Excess Of 1/2 Psig KPaPressure Testing Heater GAS Connections Installing LogsFor Your Safety Read Before Lighting Operating FireplaceLighting Instructions Inspecting Burners Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationBurner Flame Pattern Cleaning MaintenanceBurner Primary AIR Holes Main BurnerBlow air into the primary air holes on the injector holder CabinetObserved Problem Possible Cause Remedy TroubleshootingSee Cleaning and Mainte On windows Tilation air Gas leak. See Warning Replacement Parts SpecificationsService Hints Technical ServiceModels CF26PTA and CF26NTA Illustrated Parts BreakdownParts List 20-1 11-1 20-3 11-2 KEY Part Number Description QTY Accessories Cabinet Mantel with Full Hearth Base Cleaning KIT GCKInformation Video Not ShownParts Central 113896-01B Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS BAY Front Fireplace

CF26NTA specifications

Desa CF26NTA is a highly versatile and innovative diesel generator designed to meet the power needs of various applications. With its robust construction and efficient performance, the CF26NTA serves as an ideal power solution for both residential and commercial use, particularly in regions where grid power is unreliable or unavailable.

One of the main features of the Desa CF26NTA is its powerful 26 kVA output, which provides ample energy to support multiple appliances and systems simultaneously. This generator is capable of handling the demands of larger homes, construction sites, and outdoor events, ensuring that essential functions are maintained even during power outages.

The CF26NTA utilizes advanced technology to provide reliable power while minimizing fuel consumption and emissions. Equipped with a high-efficiency diesel engine, this generator offers extended run times and an impressive fuel economy, making it a cost-effective choice for long-term power needs. The engine complies with stringent environmental regulations, ensuring that users can operate it with confidence regarding its impact on the environment.

Another notable characteristic of the Desa CF26NTA is its user-friendly control panel, which features easy-to-read gauges and indicators. This design allows operators to monitor essential parameters such as voltage, frequency, and fuel levels at a glance, facilitating efficient management of the generator's operation. Additionally, the generator is fitted with automatic voltage regulation (AVR) technology, providing stable power output and protecting connected devices from voltage fluctuations.

Portability is an essential aspect of the CF26NTA, as it is designed with a compact frame and integrated wheels for easy transportation. Whether moving it between job sites or relocating for outdoor events, users will appreciate the generator's ease of mobility without compromising its stability during operation.

The Desa CF26NTA is built to withstand the rigors of demanding environments. It features weather-resistant casing and a durable design that ensures longevity and dependability even in challenging conditions. Furthermore, its maintenance-friendly layout allows for easy access to key components, simplifying routine servicing and upkeep.

In summary, the Desa CF26NTA stands out with its robust power output, efficient diesel engine technology, user-friendly features, and portable design. It is an excellent choice for anyone in need of a reliable generator that combines performance with convenience, making it suitable for various applications, from home use to commercial settings.