Desa CF26NTA installation manual See Cleaning and Mainte

Page 24

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

ODS/pilot lights but flame

1. Control knob not fully pressed in

1.

Press in control knob fully

goes out when control knob is

2. Control knob not pressed in

2.

After ODS/pilot lights, keep con-

released

 

long enough

 

trol knob pressed in 30 seconds

 

3.

Equipment shutoff valve not

3.

Fully open equipment shutoff

 

 

fully open

 

valve

 

4.

Pilot flame not touching ther-

4.

A) Contact local natural or

 

 

mocouple, which allows ther-

 

propane/LP gas company

 

 

mocouple to cool, causing

 

B) Clean ODS/pilot (see

 

 

pilot flame to go out. This

 

 

 

problem could be caused by

 

Cleaning and Maintenance,

 

 

one or both of the following:

 

page 21) or replace ODS/pilot

 

 

A) Low gas pressure

 

assembly

 

 

B) Dirty or partially clogged

 

 

 

 

ODS/pilot

 

 

 

5.

Thermocouple connection

5.

Hand tighten until snug, then

 

 

loose at control valve

 

tighten 1/4 turn more

 

6.

Thermocouple damaged

6.

Replace pilot assembly

 

7.

Control valve damaged

7.

Replace control valve

 

 

 

 

Burner does not light after

1. Inlet gas pressure is too low

1.

Contact local natural or pro-

ODS/pilot is lit

2.

Burner orifice(s) clogged

 

pane/LP gas company

 

2.

Clean burner(s) (see Cleaning

 

 

 

 

and Maintenance, page 21) or

 

 

 

 

replace burner orifice

 

 

 

 

Delayed ignition of burner

1. Manifold pressure is too low

1.

Contact local natural or pro-

 

2.

Burner orifice(s) clogged

 

pane/LP gas company

 

2.

Clean burner(s) (see Cleaning

 

 

 

 

and Maintenance, page 21) or

 

 

 

 

replace burner orifice

 

 

 

 

Burner backfiring during com-

1. Burner orifice is clogged or

1.

Clean burner (see Cleaning

bustion

 

damaged

 

and Maintenance, page 21)

 

 

 

 

or replace burner orifice

 

2.

Damaged burner

2.

Replace damaged burner

 

3.

Gas regulator defective

3.

Replace gas control

 

 

 

 

Slight smoke or odor during

1. Not enough air

1.

Check burner for dirt and

initial operation

 

 

 

debris. If found, clean burner

 

 

 

 

(see Cleaning and Mainte-

 

2.

Gas regulator defective

 

nance, page 21)

 

2.

Replace gas control

 

3.

Residues from manufacturing

3.

Problem will stop after a few

 

 

processes and logs curing

 

hours of operation

24

www.desatech.com

113896-01B

Image 24
Contents What to do if YOU Smell GAS Table of Contents Safety Information Local Codes UnpackingProduct Features Safety PilotProduct Identification Piezo Ignition SystemAIR for Combustion Ventilation Determining FRESH-AIR Flow for Fireplace LocationUnusually Tight Construction Confined and Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Check GAS TypeLocating Fireplace BUILT-IN Fireplace Installation Rough Opening for Installing WallMantel Clearances for Built-In Installation Attaching Fireplace to Wall StudsOptional Mantel Installation Removing Brick Liner RetainerAssembling Trim Trim shipped with mantelInstalling Blower Assembly GA3450T Removing HoodInstalling Blower Bracket Assembly For Built-In Installation Connecting to GAS Supply Installation Items NeededConnecting Fireplace to GAS Supply Propane/LPNatural From Checking GAS Connections Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaTest Pressures In Excess Of 1/2 Psig KPaInstalling Logs Pressure Testing Heater GAS ConnectionsFor Your Safety Read Before Lighting Operating FireplaceLighting Instructions Manual Lighting Procedure Inspecting BurnersTo Turn OFF GAS To Appliance Thermostat Control OperationCleaning Maintenance Burner Flame PatternBurner Primary AIR Holes Main BurnerCabinet Blow air into the primary air holes on the injector holderTroubleshooting Observed Problem Possible Cause RemedySee Cleaning and Mainte On windows Tilation air Gas leak. See Warning Specifications Replacement PartsService Hints Technical ServiceIllustrated Parts Breakdown Models CF26PTA and CF26NTAParts List 20-1 11-1 20-3 11-2 KEY Part Number Description QTY Accessories Cleaning KIT GCK Cabinet Mantel with Full Hearth BaseInformation Video Not ShownParts Central 113896-01B Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS BAY Front Fireplace

CF26NTA specifications

Desa CF26NTA is a highly versatile and innovative diesel generator designed to meet the power needs of various applications. With its robust construction and efficient performance, the CF26NTA serves as an ideal power solution for both residential and commercial use, particularly in regions where grid power is unreliable or unavailable.

One of the main features of the Desa CF26NTA is its powerful 26 kVA output, which provides ample energy to support multiple appliances and systems simultaneously. This generator is capable of handling the demands of larger homes, construction sites, and outdoor events, ensuring that essential functions are maintained even during power outages.

The CF26NTA utilizes advanced technology to provide reliable power while minimizing fuel consumption and emissions. Equipped with a high-efficiency diesel engine, this generator offers extended run times and an impressive fuel economy, making it a cost-effective choice for long-term power needs. The engine complies with stringent environmental regulations, ensuring that users can operate it with confidence regarding its impact on the environment.

Another notable characteristic of the Desa CF26NTA is its user-friendly control panel, which features easy-to-read gauges and indicators. This design allows operators to monitor essential parameters such as voltage, frequency, and fuel levels at a glance, facilitating efficient management of the generator's operation. Additionally, the generator is fitted with automatic voltage regulation (AVR) technology, providing stable power output and protecting connected devices from voltage fluctuations.

Portability is an essential aspect of the CF26NTA, as it is designed with a compact frame and integrated wheels for easy transportation. Whether moving it between job sites or relocating for outdoor events, users will appreciate the generator's ease of mobility without compromising its stability during operation.

The Desa CF26NTA is built to withstand the rigors of demanding environments. It features weather-resistant casing and a durable design that ensures longevity and dependability even in challenging conditions. Furthermore, its maintenance-friendly layout allows for easy access to key components, simplifying routine servicing and upkeep.

In summary, the Desa CF26NTA stands out with its robust power output, efficient diesel engine technology, user-friendly features, and portable design. It is an excellent choice for anyone in need of a reliable generator that combines performance with convenience, making it suitable for various applications, from home use to commercial settings.