Desa CF26NTA Operating Fireplace, For Your Safety Read Before Lighting, Lighting Instructions

Page 19

OPERATING FIREPLACE

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result causing property damage, per- sonal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighborʼs phone. Follow the gas supplierʼs instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, donʼt try to repair it, call a qualified service tech- nician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Open a window to vent smell. This will only last a few hours.

1.STOP! Read the safety information above.

2.Make sure equipment shutoff valve is fully open.

3.Turn control knob clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, column 1. If you donʼt smell gas, go to the next step.

5.Turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 29).

Note: You may be running this heater for the first time after hooking up to gas sup- ply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 20.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute for system to reset before lighting pilot again.

8.Turn control knob counterclockwise to desired heating level. The burners should light. Set control knob to any heat level between HI and LO.

CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

Ignitor Button

Control Knob

Figure 29 - Control Knob and Ignitor Button

Ignitor

Thermocouple

Electrode

Pilot

 

 

Burner

Figure 30 - Pilot (Propane/LP Shown)

113896-01B

www.desatech.com

19

Image 19
Contents What to do if YOU Smell GAS Table of Contents Safety Information Unpacking Local CodesPiezo Ignition System Product FeaturesSafety Pilot Product IdentificationConfined and Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Unusually Tight ConstructionVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationLocating Fireplace Rough Opening for Installing Wall BUILT-IN Fireplace InstallationAttaching Fireplace to Wall Studs Mantel Clearances for Built-In InstallationTrim shipped with mantel Optional Mantel InstallationRemoving Brick Liner Retainer Assembling TrimRemoving Hood Installing Blower Assembly GA3450TInstalling Blower Bracket Assembly For Built-In Installation Installation Items Needed Connecting to GAS SupplyPropane/LP Connecting Fireplace to GAS SupplyNatural From KPa Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Test Pressures In Excess Of 1/2 PsigPressure Testing Heater GAS Connections Installing LogsOperating Fireplace For Your Safety Read Before LightingLighting Instructions Thermostat Control Operation Manual Lighting ProcedureInspecting Burners To Turn OFF GAS To ApplianceMain Burner Cleaning MaintenanceBurner Flame Pattern Burner Primary AIR HolesBlow air into the primary air holes on the injector holder CabinetObserved Problem Possible Cause Remedy TroubleshootingSee Cleaning and Mainte On windows Tilation air Gas leak. See Warning Technical Service SpecificationsReplacement Parts Service HintsModels CF26PTA and CF26NTA Illustrated Parts BreakdownParts List 20-1 11-1 20-3 11-2 KEY Part Number Description QTY Accessories Not Shown Cleaning KIT GCKCabinet Mantel with Full Hearth Base Information VideoParts Central 113896-01B Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS BAY Front Fireplace

CF26NTA specifications

Desa CF26NTA is a highly versatile and innovative diesel generator designed to meet the power needs of various applications. With its robust construction and efficient performance, the CF26NTA serves as an ideal power solution for both residential and commercial use, particularly in regions where grid power is unreliable or unavailable.

One of the main features of the Desa CF26NTA is its powerful 26 kVA output, which provides ample energy to support multiple appliances and systems simultaneously. This generator is capable of handling the demands of larger homes, construction sites, and outdoor events, ensuring that essential functions are maintained even during power outages.

The CF26NTA utilizes advanced technology to provide reliable power while minimizing fuel consumption and emissions. Equipped with a high-efficiency diesel engine, this generator offers extended run times and an impressive fuel economy, making it a cost-effective choice for long-term power needs. The engine complies with stringent environmental regulations, ensuring that users can operate it with confidence regarding its impact on the environment.

Another notable characteristic of the Desa CF26NTA is its user-friendly control panel, which features easy-to-read gauges and indicators. This design allows operators to monitor essential parameters such as voltage, frequency, and fuel levels at a glance, facilitating efficient management of the generator's operation. Additionally, the generator is fitted with automatic voltage regulation (AVR) technology, providing stable power output and protecting connected devices from voltage fluctuations.

Portability is an essential aspect of the CF26NTA, as it is designed with a compact frame and integrated wheels for easy transportation. Whether moving it between job sites or relocating for outdoor events, users will appreciate the generator's ease of mobility without compromising its stability during operation.

The Desa CF26NTA is built to withstand the rigors of demanding environments. It features weather-resistant casing and a durable design that ensures longevity and dependability even in challenging conditions. Furthermore, its maintenance-friendly layout allows for easy access to key components, simplifying routine servicing and upkeep.

In summary, the Desa CF26NTA stands out with its robust power output, efficient diesel engine technology, user-friendly features, and portable design. It is an excellent choice for anyone in need of a reliable generator that combines performance with convenience, making it suitable for various applications, from home use to commercial settings.