Desa CDV34PA, CDV34NA DIRECT-VENT Fireplace NATURAL/PROPANE/LP, Safety Information

Page 2

CDV34NA, PA

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)

SAFETY

INFORMATION

WARNINGS

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, oper- ate, or service this fireplace. Im- proper use of this fireplace can cause serious injury or death from burns, fire, explosions, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

This fireplace is a vented product. This fireplace will not produce any gas leakage into your home if properly installed. This fireplace must be properly installed by a qualified service person. The glass door must be properly seated and sealed. If this unit is not properly installed by a qualified service person with glass door properly seated and sealed, gas leakage can occur.

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the fireplace may not have been installed properly. Get fresh air at once! Have fireplace inspected and ser- viced by a qualified service person. Some people are more affected by carbon monox- ide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Propane/LP gas and natural gas are both odorless. An odor-making agent is added to each of these gases. The odor helps you detect a gas leak. However, the odor added to these gases can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.

WARNING: Any change to this fireplace or its controls can be dangerous.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used.

2.For propane/LP fireplace, do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors. To prevent perfor- mance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity.

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier's instructions

if you cannot reach you gas supplier, call the fire department.

4.Never install the fireplace

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 42" from the front, top, or sides of the fireplace

in high traffic areas

in windy or drafty areas

5.This fireplace reaches high tempera- tures. Keep children and adults away from hot surfaces to avoid burns or cloth- ing ignition. Fireplace will remain hot for a time after shutdown. Allow surfaces to cool before touching.

6.Carefully supervise young children when they are in the room with fireplace.

7.Do not modify this fireplace under any circumstances. Any parts removed for servicing must be replaced prior to op- erating fireplace.

8.Turn fireplace off and let cool before servicing, installing, or repairing. Only a qualified service person should in- stall, service, or repair this fireplace. Have fireplace inspected annually by a qualified service person.

9.You must keep control compartments, burners, and circulating air passages clean. More frequent cleaning may be needed due to excessive lint and dust from carpeting, bedding material, etc. Turn off the gas valve and pilot light before cleaning fireplace.

10.Have venting system inspected annu- ally by a qualified service person. If needed, have venting system cleaned or repaired. See Cleaning and Mainte- nance, page 26.

11.Keep the area around your fireplace clear of combustible materials, gaso- line, and other flammable vapor and liquids. Do not run fireplace where these are used or stored. Do not place items such as clothing or decorations on or around fireplace.

12.Do not use this fireplace to cook food or burn paper or other objects.

13.Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this fireplace. Use only the gas type indicated on fire- place nameplate.

14.This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electri- cal Code, ANS/NFPA 70, or the Cana- dian Electrical Code, CSA C22.1.

15.Do not obstruct the flow of combus- tion and ventilation air in any way. Pro- vide adequate clearances around air openings into the combustion chamber along with adequate accessibility clear- ance for servicing and proper operation.

16.Do not install fireplace directly on car- peting, vinyl tile, or any combustible material other than wood. The fireplace must set on a metal or wood panel ex- tending the full width and depth of the fireplace.

17.Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service person to ar- range for replacement of the unit.

18.Do not operate fireplace if any log is broken.

19.Do not use a blower insert, heat ex- changer insert, or other accessory not approved for use with this fireplace.

20.Do not operate fireplace with glass door removed, cracked, or broken.

2

105982

Image 2
Contents Natural GAS Model CDV34NA PROPANE/LP GAS Model CDV34PA For Your SafetyFor Your Safety What to do if YOU Smell GAS Safety Information DIRECT-VENT Fireplace NATURAL/PROPANE/LPLocal Codes Product FeaturesProduct Identification Glossary TermsLocation and Space Requirements PRE-INSTALLATION PreparationClearances Framing and FinishingGeneral Venting Location of Vent TerminationGeneral Venting Installation Planning Venting InstallationInstallation Precautions Installing Vent System in a ChaseInstallation for Horizontal Termination Snorkel TerminationVent Pipe Connections Horizontal Termination Configurations Horizontal VentingVenting with Two 90 Elbows Cathedral Ceiling Installation Installation for Vertical TerminationFlat Ceiling Installation Vertical Termination Configurations Venting with One 90 ElbowVertical Venting Comfort Glow Rigid Venting High Altitude InstallationParts Lists for Venting Kits and Components Comfort Glow Flexible VentingInstalling GA3750/CDA3620T Blowers Fireplace InstallationInstalling Optional Blower Accessory Check GAS TypeIf your fireplace system is installed Installing GAS Piping to Fireplace Location Installation Items NeededChecking GAS Connections Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas Connections Close manual shutoff valve see Fig- ureREMOVING/REPLACING Glass Door Installing Optional Wireless HAND-HELD Remote ControlInstalling 9-Volt Alkaline Battery into Receiver Installing Optional Brick Liner CD8037A Attaching Magnetic Decorative Brass StripsInstalling LOGS, Lava Rock and Glowing Embers Installing Log NoOperating Fireplace For Your Safety Read Before LightingManual Lighting Procedure Lighting InstructionsInspecting Burners Operating Optional Blower AccessoryPilot Assembly Optional Remote OperationPilot and Burners Cleaning and MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Wiring Diagram Replacement PartsService Hints Technical ServiceAccessories Illustrated Parts Breakdown CDV34NA CDV34PA33Parts List DIRECT-VENT Fireplace CDV34NA CDV34PAWarranty Information

CDV34PA, CDV34NA specifications

Desa CDV34NA and CDV34PA are two prominent models in the Desa vent-free gas fireplace series, renowned for their efficiency, craftsmanship, and modern design. These fireplaces offer an ambient warmth while combining style with practicality, making them a popular choice for homeowners looking to enhance their living spaces.

One of the key features of the CDV34NA and CDV34PA is the vent-free technology. This innovative design allows for the direct burning of gas without the necessity of a chimney or venting system. As a result, these fireplaces can be installed in various locations within the home, providing flexibility that traditional fireplaces cannot match. The absence of a flue system also means that no heat is lost during the exhaust process, allowing for maximum energy efficiency.

Both models are equipped with advanced safety features. They include an Oxygen Depletion Sensor (ODS) that automatically shuts off the unit if oxygen levels fall below a safe threshold. This technology not only ensures the safety of users but also enhances peace of mind while operating the fireplace. Additionally, the CDV34 series features a built-in thermocouple that regulates the temperature, providing an added layer of safety by preventing overheating.

When it comes to aesthetics, the CDV34NA and CDV34PA do not disappoint. They feature a modern, sleek design that complements a variety of interior decors. Available in stylish finishes, these units can seamlessly blend into contemporary homes or traditional settings. The large viewing windows provide a captivating view of the flames, creating an inviting ambiance ideal for any gathering.

Performance-wise, both models deliver impressive heating capabilities. With adjustable heat output settings, users can customize the warmth to suit their preferences. The units operate quietly, enhancing the overall comfort of the environment without disruptive fan noise. Additionally, the CDV34NA model runs on natural gas, while the CDV34PA uses propane, providing options based on the homeowner's available gas supply.

In conclusion, the Desa CDV34NA and CDV34PA are exceptional options for those seeking a versatile and stylish heating solution. With their vent-free technology, enhanced safety features, and elegant design, these fireplaces are perfect for adding warmth and character to any indoor space. Whether for new constructions or renovations, these models offer the right blend of function and form for today's discerning homeowners.