Attaching Wood Base to Solid Floor

For attaching base to solid floors (concrete or masonry)

Note: Floor anchors and mounting screws are in hardware package. The hardware pack- age is provided with fireplace.

1.Drill holes at marked locations using 5/16" drill bit. For solid floors (concrete or masonry), drill at least 1" deep.

2.Fold floor anchor as shown in Figure 15.

3.Insert floor anchor (wings first) into hole. Tap anchor flush to floor.

4.Insert mounting screws through base and into floor anchors.

5.Tighten screws until base is firmly fas- tened to floor.

Figure 15 - Folding Anchor

CONNECTING TO GAS SUPPLY

NOTICE: A qualified service per- son must connect fireplace to gas supply. Follow all local codes.

WARNING: Never connect fireplace to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

IMPORTANT: Check gas line pressure before connecting fireplace to gas line. Gas line pressure must be no greater than 14 inches of water. If gas line pressure is higher, fireplace regulator damage could occur.

CAUTION : Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" or greater diameter to allow proper gas volume to fireplace. If pipe is too small, undue loss of pressure will occur.

Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 16).

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.

CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

Install sediment trap in supply line as shown in Figure 16. Locate sediment trap where it is within reach for cleaning. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.

 

A.G.A. Design-Certified Manual

From

Shutoff Valve With 1/8" NPT Tap*

 

Gas Meter

 

(5" W.C.** to

Approved Flexible

10.5" W.C.

Gas Hose

Pressure)

 

Gas

Control

 

Tee

 

Sediment

Joint

 

Trap

Pipe

3" Minimum

 

Nipple

 

 

Cap

 

Figure 16 - Gas Connection

*Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 21.

**Minimum inlet pressure for purpose of input adjustment.

Continued

104326

11

Image 11
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualShown with Optional Cabinet Mantel/Hearth Base Accessory VENT-FREE Natural GAS Compact Fireplace Safety InformationUnpacking Product FeaturesProduct Identification Local CodesAssembling Hood AssemblyInstalling Log Assembling FireplaceConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationInstallation Items Locating FireplaceRough Opening for Installing in Wall BUILT-IN Fireplace InstallationAssembling Brass Trim Brass trim shipped with mantel Mantel Clearances for BUILT-IN InstallationOptional Mantel Installation Reinstall top brass louversFor attaching base to solid floors concrete or masonry Connecting to GAS SupplyAttaching Wood Base to Solid Floor Valve should be accessible Connecting Fireplace to GAS SupplyInstallation Items Needed Checking GAS Connections Installing 9-VOLT Battery for Wireless Remote ControlLighting Instructions For Your Safety Read Before LightingOperating Fireplace Hand Held Remote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationInspecting Burners Cleaning and MaintenanceReplacement Parts Observed Problem Possible Cause Remedy TroubleshootingPane gas company Lation requirementsGas leak. See Warning statement at top Gas odor even when control knob is in OFF positionTop Wiring Diagram SpecificationsService Hints Technical ServiceAccessories CGCF26NR Illustrated Parts BreakdownKEY Description QTY Parts ListLimited Warranty VENT-FREE Natural GAS Compact Fireplace Warranty Information