Desa CGCF26NR installation manual Connecting Fireplace to GAS Supply, Installation Items Needed

Page 12

CGCF26NR

VENT-FREE NATURAL GAS COMPACT FIREPLACE

INSTALLATION

Continued

CONNECTING FIREPLACE TO GAS SUPPLY

Installation Items Needed

Phillips screwdriver

sealant (resistant to propane gas, not pro- vided)

1.

Remove fireplace screen. Remove two

 

screws that hold fireplace screen in

 

place for shipping. These screws are

 

located near top of screen. Discard

 

screws. Lift fireplace screen up and pull

 

out to remove.

2.

Remove screws that attach branch sup-

 

port to fireplace (see Figure 17). Care-

 

fully lift up branch support and remove

 

from fireplace (see Figure 17).

3.

Route flexible gas line (provided by

 

installer) from manual shutoff valve

 

into fireplace through side or rear ac-

Screen Shipping

ScrewScreen

Shoulder

Screw

Branch

Support

Figure 17 - Removing Branch Support From Fireplace

To Fireplace

Gas Valve

cess holes in outer casing. Route flex-

ible gas supply line through fireplace

access holes in outer casing.

NOTICE : Most building codes do not permit concealed gas con- nections. A flexible gas line is provided to allow accessibility from the fireplace (see Figure 18). The flexible gas supply line con- nection to the manual shutoff

Manual Shutoff Valve

To Gas

Supply

Gas Connector

Flexible Gas Line from

Manual Shutoff Valve

Provided by Installer

Flexible Gas Line from Fireplace Gas Valve Provided with Fireplace

valve should be accessible.

4.Apply pipe joint sealant lightly to male threads of gas connector attached to flexible gas line (see Figure 18). Con- nect flexible gas line to flexible gas line attached to gas valve of fireplace (see Figure 18).

5.Check all gas connections for leaks. See Checking Gas Connections, page 13.

6.Replace branch support back into fire- place. Feed flexible gas line into fire- place base area while replacing branch support. Make sure the entire flexible gas line is in fireplace base area. Reat- tach branch support to fireplace with screws removed in step 3.

Figure 18 - Attaching Flexible Gas Lines Together

12

104326

Image 12
Contents OWNER’S Operation and Installation Manual Shown with Optional Cabinet Mantel/Hearth Base AccessoryWhat to do if YOU Smell GAS Safety Information VENT-FREE Natural GAS Compact FireplaceProduct Features Product IdentificationLocal Codes UnpackingAssembly Installing LogAssembling Fireplace Assembling HoodAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Fireplace LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Installation ItemsLocating Fireplace Check GAS TypeBUILT-IN Fireplace Installation Rough Opening for Installing in WallMantel Clearances for BUILT-IN Installation Optional Mantel InstallationReinstall top brass louvers Assembling Brass Trim Brass trim shipped with mantelConnecting to GAS Supply Attaching Wood Base to Solid FloorFor attaching base to solid floors concrete or masonry Connecting Fireplace to GAS Supply Installation Items NeededValve should be accessible Installing 9-VOLT Battery for Wireless Remote Control Checking GAS ConnectionsFor Your Safety Read Before Lighting Operating FireplaceLighting Instructions Manual Lighting Procedure To Turn OFF GAS To ApplianceThermostat Control Operation Hand Held Remote OperationCleaning and Maintenance Replacement PartsInspecting Burners Troubleshooting Observed Problem Possible Cause RemedyLation requirements Pane gas companyGas odor even when control knob is in OFF position TopGas leak. See Warning statement at top Specifications Service HintsTechnical Service Wiring DiagramAccessories Illustrated Parts Breakdown CGCF26NRParts List KEY Description QTYWarranty Information Limited Warranty VENT-FREE Natural GAS Compact Fireplace