CGCF26NR
VENT-FREE NATURAL GAS COMPACT FIREPLACE
INSTALLATION
Continued
CONNECTING FIREPLACE TO GAS SUPPLY
Installation Items Needed
•Phillips screwdriver
•sealant (resistant to propane gas, not pro- vided)
1. | Remove fireplace screen. Remove two |
| screws that hold fireplace screen in |
| place for shipping. These screws are |
| located near top of screen. Discard |
| screws. Lift fireplace screen up and pull |
| out to remove. |
2. | Remove screws that attach branch sup- |
| port to fireplace (see Figure 17). Care- |
| fully lift up branch support and remove |
| from fireplace (see Figure 17). |
3. | Route flexible gas line (provided by |
| installer) from manual shutoff valve |
| into fireplace through side or rear ac- |
Screen Shipping
ScrewScreen
Shoulder
Screw
Branch
Support
Figure 17 - Removing Branch Support From Fireplace
To Fireplace
Gas Valve
cess holes in outer casing. Route flex- |
ible gas supply line through fireplace |
access holes in outer casing. |
NOTICE : Most building codes do not permit concealed gas con- nections. A flexible gas line is provided to allow accessibility from the fireplace (see Figure 18). The flexible gas supply line con- nection to the manual shutoff
Manual Shutoff Valve
To Gas
Supply➞
Gas Connector
Flexible Gas Line from
Manual Shutoff Valve
Provided by Installer
➞
Flexible Gas Line from Fireplace Gas Valve Provided with Fireplace
valve should be accessible.
4.Apply pipe joint sealant lightly to male threads of gas connector attached to flexible gas line (see Figure 18). Con- nect flexible gas line to flexible gas line attached to gas valve of fireplace (see Figure 18).
5.Check all gas connections for leaks. See Checking Gas Connections, page 13.
6.Replace branch support back into fire- place. Feed flexible gas line into fire- place base area while replacing branch support. Make sure the entire flexible gas line is in fireplace base area. Reat- tach branch support to fireplace with screws removed in step 3.
Figure 18 - Attaching Flexible Gas Lines Together
12 | 104326 |