Desa CTDV36NRA, VT36PA Inspecting Burners, Operating Optional GWMT1 Wall Mounted Thermostat

Page 27

OPERATING FIREPLACE

Optional Hand-Held Remote Operation (Cont.)

Operating Optional GWMT1 Wall Mounted Thermostat

Operating Optional Blower Accessory

INSPECTING BURNERS

Pilot Assembly

Burner Flame Pattern

OPERATING FIREPLACE

Continued

27

Auto Shutoff Feature

1.If the average room temperature exceeds 82 degrees Fahr- enheit (28 degrees Centigrade), the hand-held remote con- trol will perform a safety override and shut the fireplace off. This feature is not available in the MANU mode.

2.The receiver continuously receives signals from the hand- held remote to control the room temperature. If the hand- held remote is misplaced, obstructed, or for any reason cannot transmit to the receiver, the receiver will shut off the fireplace after 8 minutes.

Key Pad Lock Feature

This feature allows the user to lock/unlock the keypad on the hand-held remote in the MANU or AUTO mode to prevent inadvertent operation (i.e. children operating the hand-held re- mote control, etc.). The keypad is locked in either on or off. Press the POWER and LOCK buttons together to turn the unit on or off.

OPERATING OPTIONAL GWMT1

WALL MOUNTED THERMOSTAT

WARNING: Do not connect the thermostat to a power source. Electrical shock and/or a fire hazard will occur.

Light the fireplace as instructed in Lighting Instructions on page 25. Set wall thermostat to desired temperature.

This thermostat has been electronically calibrated at the factory and requires no adjustment or leveling.

Upon installation, the thermostat must be allowed to stabilize at room temperature for a minimum of 30 minutes for proper operation.

To turn the fireplace off, adjust thermostat to the lowest setting and turn the gas control knob back to PILOT. The pilot will remain lit.

IMPORTANT: To turn the pilot off, turn the gas control knob on the heater to the OFF position.

OPERATING OPTIONAL

BLOWER ACCESSORY

Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the left side of the switch bracket to the left just inside the louver panel.

The BK manual blower and the BKT thermostatically-con- trolled blower have an ON setting and an OFF setting. The blower will only run when the switch is in the ON position. In the OFF position, the blower will not operate.

Note for BKT Only: If you are using BKT blower with optional thermostat (wall mounted or remote control) for the fireplace, your fireplace and blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.

The blower helps distribute heated air from the fireplace. Periodically check the louvers of the firebox and remove any dust, dirt, or other obstructions that will hinder the flow of air.

INSPECTING BURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT ASSEMBLY

The pilot assembly is factory preset for the proper flame height. Alterations may have occurred during shipping and handling. Call a qualified service person to readjust the pilot if necessary.

The height of the thermopile must be 3/8" to 1/2" above the pilot flame as shown in Figure 55. The thermocouple must be at a height of about 1/8" above the pilot flame. The flame from the pilot burner must extend beyond both the thermocouple and thermopile.

If you pilot assembly does not meet these requirements:

turn fireplace off (see To Turn Off Gas to Appliance, page 25)

see Troubleshooting, pages 29 through 31

Thermopile

3/8" to 1/2"

Pilot Burner

1/8"

Thermocouple

Piezo

Ignitor

Figure 55 - Pilot Assembly

BURNER FLAME PATTERN

Burner flames will be steady; not lifting or floating. Flame patterns will be different from unit to unit and will vary depending on installation type and weather conditions.

If the vent configuration is installed incorrectly, the flames will lift or "ghost". This can be dangerous. Inspect the flames after installa- tion to ensure proper installation and performance.

For morevisit www..com

111250-01A

Image 27
Contents For Your Safety What to do if YOU Smell GAS For Your SafetySafety Information Table of ContentsLocal Codes Safety Information Product IdentificationProduct Features PRE-INSTALLATION PreparationLocation and Space Requirements Framing and Finishing ClearancesBalcony with Perpendicular Side Wall Location of Termination CAPHorizontal Termination Installation Venting Installation InstructionsInstallation Precautions Installation PlanningVent Pipe Connections Installing Horizontal Vent Cap Noncombustible Exterior Square Termination Horizontal Termination ConfigurationsCorner and Alternate Installation Venting with Two 90 Elbows Horizontal System Installation Using TWO ElbowsFlat Ceiling Installation Installation for Vertical TerminationVenting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting High Altitude InstallationCheck GAS Type Fireplace InstallationParts Lists for Venting Kits and Components Installing Optional Blower AccessoriesAttaching Speed Control to Firebox Model BKT InstallationBlower Model BKT Blower Wiring DiagramInstallation Items Needed Installing GAS Piping to Fireplace LocationChecking GAS Connections Connecting Fireplace to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemInstalling Optional Wall Mount Switch GWMS2 Pressure Testing Fireplace Gas ConnectionsInstalling Remote Receiver Removing Glass Door Cleaning Glass DoorREMOVING/REPLACING Glass Door Removing Louver PanelsInstalling Left Side Brick Panel Installing LOGS, Lava Rock and Glowing EmbersInstalling Logs No and No Lighting Instructions For Your Safety Read Before LightingManual Lighting Procedure Operating FireplaceOptional HAND-HELD Remote Operation Thermostat Series Model GhrctbON/OFF Series Model Ghrcb Operating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning and MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementIllustrated Parts Breakdown VT36PRA, VT36PRBACTDV36NRA VT36PA, VT36PBA, VT36PRA, VT36PRBA, CTDV36NRA Parts ListSpecifications Replacement PartsService Hints Technical ServiceOwners Registration Form Postage Required Manual Blower KIT BK AccessoriesFlexible GAS Line Connector GA5081 PROPANE/NATURAL GAS Conversion KITWarranty Information

VT36PA, CTDV36NRA, VT36NA specifications

The Desa VT36NA, CTDV36NRA, and VT36PA are popular models in the realm of gas fireplaces, providing efficient heating solutions while enhancing the aesthetic appeal of any space. These models are designed to deliver comfort, convenience, and sophisticated design, making them ideal choices for residential and commercial applications.

One of the standout features of these models is their innovative heating technology. Utilizing advanced gas control systems, they offer precise temperature management, allowing users to enjoy consistent warmth with ease. The inclusion of a variable speed blower ensures better air circulation, maximizing the heating efficiency and comfort level throughout the room.

The VT36NA model boasts a direct vent design, which means it draws air for combustion from outside, ensuring that indoor air quality remains untainted. This feature is particularly beneficial in tightly sealed homes where indoor air quality can be compromised. The dual venting option also provides flexibility in installation, allowing for either horizontal or vertical venting, which adds to the model's versatility.

The CTDV36NRA, on the other hand, is designed with a contemporary aesthetic in mind, featuring a sleek and modern front that complements any modern décor. With a variable flame height option, users can easily adjust the fire intensity according to their preferences, providing both ambiance and warmth. The accent lighting feature further enhances the visual appeal, allowing the fireplace to become a focal point in any room.

The VT36PA model is equipped with enhanced safety features, including an automatic shut-off system and flame supervision devices. These safety measures provide peace of mind while operating, ensuring that the fireplace is both effective and secure for regular use. Additionally, the model is capable of using either natural gas or propane, adding versatility to fuel options depending on user preference or availability.

In terms of energy efficiency, all three models meet rigorous standards, making them environmentally friendly options for heating. With their low emissions and high-efficiency ratings, they contribute to reducing overall energy consumption.

Overall, the Desa VT36NA, CTDV36NRA, and VT36PA models offer a blend of functionality, modern technology, and aesthetic appeal. With their range of features and customizable options, they are ideal for those looking to enhance their living spaces with reliable heating solutions that also serve as elegant focal points. Whether for a cozy family gathering or a modern entertainment area, these fireplaces provide both comfort and style, making them excellent additions to any home.