Desa installation manual LFP33PRA Unvented PROPANE/LP GAS Fireplace, Safety Information

Page 2

LFP33PRA

UNVENTED PROPANE/LP GAS FIREPLACE

SAFETY

INFORMATION

WARNINGS

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace. Improper use of this fireplace can cause se- rious injury or death from burns, fire,explosion,electricalshock,and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the fireplace may not be working properly. Get fresh air at once! Have fireplace serviced. Some people are more af- fected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influ- ence of alcohol, and those at high altitudes.

Propane/LP Gas: Propane/LP gas is odor- less. An odor-making agent is added to the gas. The odor helps you detect a gas leak. How- ever, the odor added to the gas can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.

WARNING: Any change to this heater or its controls can be dangerous.

WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.

WARNING: Do not use a blower insert, heat exchanger insert, or other accessory not ap- proved for use with this heater.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Fireplace front and screen be- comes very hot when running fireplace. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shutdown. Allow sur- faces to cool before touching.

Carefully supervise young chil- dren when they are in the room with heater. When using the hand- held remote accessory, keep se- lector switch in the OFF position to prevent children from turning on burners with remote.

You must operate this fireplace with the fireplace screen and hood in place. Make sure fire- place screen and hood are in place before running fireplace.

Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) inside any structure. Locate propane/ LP supply tank(s) outdoors.

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

4.This fireplace shall not be installed in a bedroom or bathroom.

5.Do not use this fireplace as a wood- burning fireplace. Use only the logs provided with the fireplace.

6.Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of fireplace.

7.This fireplace is designed to be smoke- less. If logs ever appear to smoke, turn off fireplace and call a qualified ser- vice person. Note: During initial op- eration, slight smoking could occur due to log curing and fireplace burning manufacturing residues.

8.To prevent the creation of soot, follow the instructions in Cleaning and Main- tenance, page 18.

9.Before using furniture polish, wax, car- pet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white pow- der residue within burner box or on adjacent walls or furniture.

10.This fireplace needs fresh air ventila- tion to run properly. This fireplace has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the fireplace if not enough fresh air is available. See Air for Combus- tion and Ventilation, pages 4 through 6. If fireplace keeps shutting off, see Troubleshooting, pages 19 through 21.

11.Do not run fireplace

• where flammable liquids or vapors are used or stored

• under dusty conditions

12.Do not use this fireplace to cook food or burn paper or other objects.

13.Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control system and any gas control which has been under water.

14.Do not operate fireplace if any log is broken. Do not operate fireplace if a log is chipped (dime-sized or larger).

15.Turn fireplace off and let cool before servicing. Only a qualified service per- son should service and repair fireplace.

2

107064

Image 2
Contents Shown with optional cabinet Mantel and hearth base OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Safety Information LFP33PRA Unvented PROPANE/LP GAS FireplaceLocal Codes Remote Control AccessoriesProduct Identification UnpackingProduct Features AIR for Combustion and VentilationDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationOptional GA3750 Blower Accessory Electrical HookupInstallation Clearances Conventional Fireplace InstallationBUILT-IN Fireplace Installation Location of Nailing FlangesInstallation Items Needed Installing GAS Piping toMantel Clearances for Built-In Installation Fireplace LocationConnecting Fireplace to GAS Supply Gas ConnectionChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Installing Logs Installing ScreenInstalling Remote Receiver Unit Optional Wireless HAND- Held Remote Control Accessory RM4Installing Batteries for RM4 Installing Batteries in ReceiverInstalling Battery in Hand-Held Remote Control Unit Installing Batteries for Cghrc and Cghrct SeriesInstalling Battery in Receiver Cghrct SeriesLighting Instructions For Your Safety Read Before LightingOperating Fireplace To Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Remote Operation Optional Blower OperationCleaning and Maintenance Inspecting BurnersTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Specifications Wiring DiagramService Hints Technical ServiceParts not Under Warranty Replacement PartsParts Under Warranty Parts CentralGMC11F Series Walnut Finished Hardwood Veneer AccessoriesCorner Mantel GMC13F Series Medium Stained Oak VeneerReceiver and HAND- Held Remote Control KIT Cghrc Series HAND-HELD Remote Control RM4Blower Accessory GA3750 Series and GA3650T Series Equipment Shutoff Valve GA5010Illustrated Parts Breakdown Remote Ready Model LFP33PRAParts List KEY Part Number Description QTYFireplace LFP33PRA Parts List Warranty Information

LFP33PRA specifications

Desa LFP33PRA is a cutting-edge product that has gained attention for its advanced features and innovative technologies. This model stands out in the market for its combination of efficiency and user-friendly design, making it an ideal choice for a diverse range of applications.

One of the main highlights of the LFP33PRA is its robust performance. Equipped with a high-capacity energy storage system, it delivers reliable power support, ensuring that users experience minimal interruptions during operation. This is particularly beneficial for environments where continuous power supply is crucial, such as in industrial settings or for emergency backup purposes.

The incorporation of state-of-the-art lithium iron phosphate (LiFePO4) battery technology sets the LFP33PRA apart from traditional battery systems. This technology not only enhances the longevity of the unit but also contributes to its safety profile. LiFePO4 batteries are known for their thermal stability and higher resistance to overheating, making them a safer choice for users.

Another key characteristic of the Desa LFP33PRA is its impressive energy density. This feature allows the device to store more energy in a smaller, lighter package. As a result, it is easier to transport and install, further increasing its versatility across various sectors. The compact design does not compromise on power output, ensuring high efficiency for all applications.

In terms of technology integration, the LFP33PRA comes with smart monitoring capabilities. Users can conveniently track energy consumption, battery status, and overall performance through a digital interface, allowing for proactive maintenance and optimization of power usage. This feature is particularly advantageous for businesses that prioritize energy management and cost-efficiency.

The design of the LFP33PRA also emphasizes sustainability. By utilizing green technology in its manufacturing process and promoting energy savings during operation, the product aligns with eco-friendly initiatives. This dedication to sustainability resonates well with consumers who are increasingly conscious of their environmental impact.

Overall, the Desa LFP33PRA is a pioneering product that combines innovative technologies, safety, efficiency, and sustainability. Its advanced features and reliable performance make it a valuable addition to both commercial and residential power solutions. Whether for backup power or as a primary energy source, the LFP33PRA is equipped to meet the demands of modern electrical systems.