Desa LFP33PRA installation manual Installation Clearances, Conventional Fireplace Installation

Page 8

LFP33PRA

UNVENTED PROPANE/LP GAS FIREPLACE

INSTALLATION

Continued

INSTALLATION

CLEARANCES

WARNING: Maintain the mini- mum clearances. If you can, pro- vide greater clearances from floor, ceiling, and adjoining wall.

Carefully follow the instructions below. This will ensure safe installation.

Minimum Clearances For Side

Combustible Material, Side Wall,

and Ceiling

A.Clearances from the side of the fire- place cabinet to any combustible ma- terial and wall should follow diagram in Figure 7.

Example: The face of a mantel, book- shelf, etc. is made of combustible ma- terial and protrudes 3 1/2" from the wall. This combustible material must be 4" from the side of the fireplace cabinet (see Figure 7).

B.Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.

 

 

 

 

 

 

 

 

 

 

121/4

 

 

 

 

 

 

 

 

 

 

 

101/2

 

 

Example

 

 

 

 

 

 

8 3/4

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

INCHES

 

 

 

 

 

 

 

 

 

 

51/4

 

 

 

 

 

 

 

 

 

 

31/2

 

 

 

 

 

 

 

 

 

 

13/4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7/8

 

 

 

 

 

 

 

 

 

 

 

7/16

 

FIREBOX

.5

1

2

4

6

8

10

12

14

16 *

 

 

 

 

 

INCHES

 

 

 

 

 

*Minimum 16 inches from Side Wall

Figure 7 - Minimum Clearance for Combustible to Wall

CONVENTIONAL FIREPLACE INSTALLATION

Conventional installation of this fireplace involves installing fireplace along with the corner, face, or cabinet mantel with hearth base accessories against a wall in your home. Follow the instructions below to install the fireplace in this manner.

Note: The instructions below show installa- tion using the cabinet mantel and hearth base accessories (see Accessories on pages 24 and 25). The hearth base accessory shown is optional for this installation. You can install fireplace and cabinet mantel directly on the floor. The corner mantel accessory cannot be installed with hearth bases. You must install corner and face mantel directly on the floor.

1.Assemble cabinet mantel, hearth base, and trim accessories. Assembly instruc- tions are included with each accessory.

2.When installing blower, install a prop- erly grounded, 120 volt three-prong electrical outlet at fireplace location if an outlet is not there. If possible, lo- cate outlet so cabinet mantel will cover it when installed (see Figure 8).

3.Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the equipment shutoff valve. The flexible gas line must be the last item installed on the gas piping. See Installing Gas Piping to Fireplace Lo- cation, page 10.

4.Place hearth base accessory against wall at installation location. Cut an ac- cess hole in hearth top to run flexible gas line to fireplace (see Figure 8). Make sure to locate access hole so cabi- net mantel will cover it when installed. Note: You can secure base to floor us- ing wood screws. Countersink screw heads and putty over.

5.Route flexible gas line through access hole in hearth base.

6.Center cabinet mantel on hearth base (see Figure 9). Make sure mantel is flush against wall.

7.Break off nailing flanges (see Figure 10, page 9) with hammer or pliers.

8.Place cardboard or other protective material on top of hearth base. Care- fully set fireplace on protective mate- rial, with back of fireplace inside man- tel opening.

9.Attach flexible gas line to fireplace gas regulator. See Connecting Fireplace to Gas Supply, page 11.

10.If blower is installed, route blower elec- trical cord through access holes in ei- ther side of fireplace. Note: Bushing may be moved if necessary. Plug elec- trical cord into electrical outlet.

 

 

 

Gas

Hearth

Flexible

Electrical

Line

Access

Base

Outlet

Gas Line

Hole

 

 

 

 

 

Figure 8 - Placing Hearth Base Accessory Against Wall

Cabinet

Mantel

Figure 9 - Installing Cabinet Mantel

8

107064

Image 8
Contents Shown with optional cabinet Mantel and hearth base OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Safety Information LFP33PRA Unvented PROPANE/LP GAS FireplaceRemote Control Accessories Product IdentificationLocal Codes UnpackingProduct Features AIR for Combustion and VentilationDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Optional GA3750 Blower AccessoryCheck GAS Type Electrical HookupInstallation Clearances Conventional Fireplace InstallationBUILT-IN Fireplace Installation Location of Nailing FlangesInstalling GAS Piping to Mantel Clearances for Built-In InstallationInstallation Items Needed Fireplace LocationConnecting Fireplace to GAS Supply Gas ConnectionChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Installing Logs Installing ScreenOptional Wireless HAND- Held Remote Control Accessory RM4 Installing Batteries for RM4Installing Remote Receiver Unit Installing Batteries in ReceiverInstalling Batteries for Cghrc and Cghrct Series Installing Battery in ReceiverInstalling Battery in Hand-Held Remote Control Unit Cghrct SeriesLighting Instructions For Your Safety Read Before LightingOperating Fireplace Manual Lighting Procedure Optional Remote OperationTo Turn OFF GAS To Appliance Optional Blower OperationCleaning and Maintenance Inspecting BurnersTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Wiring Diagram Service HintsSpecifications Technical ServiceReplacement Parts Parts Under WarrantyParts not Under Warranty Parts CentralAccessories Corner MantelGMC11F Series Walnut Finished Hardwood Veneer GMC13F Series Medium Stained Oak VeneerHAND-HELD Remote Control RM4 Blower Accessory GA3750 Series and GA3650T SeriesReceiver and HAND- Held Remote Control KIT Cghrc Series Equipment Shutoff Valve GA5010Illustrated Parts Breakdown Remote Ready Model LFP33PRAParts List KEY Part Number Description QTYFireplace LFP33PRA Parts List Warranty Information

LFP33PRA specifications

Desa LFP33PRA is a cutting-edge product that has gained attention for its advanced features and innovative technologies. This model stands out in the market for its combination of efficiency and user-friendly design, making it an ideal choice for a diverse range of applications.

One of the main highlights of the LFP33PRA is its robust performance. Equipped with a high-capacity energy storage system, it delivers reliable power support, ensuring that users experience minimal interruptions during operation. This is particularly beneficial for environments where continuous power supply is crucial, such as in industrial settings or for emergency backup purposes.

The incorporation of state-of-the-art lithium iron phosphate (LiFePO4) battery technology sets the LFP33PRA apart from traditional battery systems. This technology not only enhances the longevity of the unit but also contributes to its safety profile. LiFePO4 batteries are known for their thermal stability and higher resistance to overheating, making them a safer choice for users.

Another key characteristic of the Desa LFP33PRA is its impressive energy density. This feature allows the device to store more energy in a smaller, lighter package. As a result, it is easier to transport and install, further increasing its versatility across various sectors. The compact design does not compromise on power output, ensuring high efficiency for all applications.

In terms of technology integration, the LFP33PRA comes with smart monitoring capabilities. Users can conveniently track energy consumption, battery status, and overall performance through a digital interface, allowing for proactive maintenance and optimization of power usage. This feature is particularly advantageous for businesses that prioritize energy management and cost-efficiency.

The design of the LFP33PRA also emphasizes sustainability. By utilizing green technology in its manufacturing process and promoting energy savings during operation, the product aligns with eco-friendly initiatives. This dedication to sustainability resonates well with consumers who are increasingly conscious of their environmental impact.

Overall, the Desa LFP33PRA is a pioneering product that combines innovative technologies, safety, efficiency, and sustainability. Its advanced features and reliable performance make it a valuable addition to both commercial and residential power solutions. Whether for backup power or as a primary energy source, the LFP33PRA is equipped to meet the demands of modern electrical systems.