Desa LFP33PRA installation manual Product Features, AIR for Combustion and Ventilation

Page 4

LFP33PRA

UNVENTED PROPANE/LP GAS FIREPLACE

PRODUCT

FEATURES

OPERATION

This vent-free fireplace is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by both realistic flames and glow- ing embers. When used without the blower, the fireplace requires no electricity making it ideal for emergency backup heat.

SAFETY DEVICE

This fireplace has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff sys- tem. The ODS/pilot is a required feature for vent-free room heaters. The ODS system shuts off the fireplace if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This fireplace has a piezo ignitor. This sys- tem requires no matches, batteries, or other sources to light fireplace.

BLOWER ASSEMBLY (GA3750 & GA3650T SERIES)

This fireplace accepts an optional blower assembly. The GA3750 blower has a manual variable control. The GA3650T blower operates thermostatically. The blower circulates heated air from the fireplace into the room. Use of blower is optional. See Accessories, pages 24 and 25.

AIR FOR COMBUSTION AND VENTILATION

WARNING: This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ven- tilation air. Read the following in- structions to insure proper fresh air for this and other fuel-burning appliances in your home.

Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.

While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper com- bustion and ventilation.

Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide ad- equate fresh air for these appliances. This will insure proper venting of vented fuel- burning appliances.

PROVIDING ADEQUATE VENTILATION

The following are excerpts from National Fuel Gas Code, NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation.

All spaces in homes fall into one of the three following ventilation classifications:

1.Unusually Tight Construction

2.Unconfined Space

3.Confined Space

The information on pages 4 through 6 will help you classify your space and provide adequate ventilation.

Unusually Tight Construction

The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of

unusually tight construction, you must provide additional fresh air.

Unusually tight construction is de- fined as construction where:

a.walls and ceilings exposed to the outside atmosphere have a con- tinuous water vapor retarder with a rating of one perm (6 x 10-11kg per pa-sec-m2) or less with open- ings gasketed or sealed and

b.weather stripping has been added on openable windows and doors and

c.caulking or sealants are applied to areas such as joints around window and door frames, be- tween sole plates and floors, be- tween wall-ceiling joints, be- tween wall panels, at penetra- tions for plumbing, electrical, and gas lines, and at other openings.

If your home meets all of the three criteria above, you must provide ad- ditional fresh air. See Ventilation Air From Outdoors, page 6.

If your home does not meet all of the three criteria above, proceed to Deter- mining Fresh-Air Flow for Fireplace Location on page 5.

Confined Space and Unconfined Space

The National Fuel Gas Code, ANS Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggre- gate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are con- sidered a part of the unconfined space.

This heater shall not be installed in a con- fined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.

*Adjoining rooms are communicating only if there are doorless passageways or ventila- tion grills between them.

4

107064

Image 4
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualShown with optional cabinet Mantel and hearth base Safety Information LFP33PRA Unvented PROPANE/LP GAS FireplaceRemote Control Accessories Product IdentificationLocal Codes UnpackingProduct Features AIR for Combustion and VentilationDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Optional GA3750 Blower AccessoryCheck GAS Type Electrical HookupInstallation Clearances Conventional Fireplace InstallationBUILT-IN Fireplace Installation Location of Nailing FlangesInstalling GAS Piping to Mantel Clearances for Built-In InstallationInstallation Items Needed Fireplace LocationConnecting Fireplace to GAS Supply Gas ConnectionPressure Testing Fireplace Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Installing Logs Installing ScreenOptional Wireless HAND- Held Remote Control Accessory RM4 Installing Batteries for RM4Installing Remote Receiver Unit Installing Batteries in ReceiverInstalling Batteries for Cghrc and Cghrct Series Installing Battery in ReceiverInstalling Battery in Hand-Held Remote Control Unit Cghrct SeriesOperating Fireplace For Your Safety Read Before LightingLighting Instructions Manual Lighting Procedure Optional Remote OperationTo Turn OFF GAS To Appliance Optional Blower OperationCleaning and Maintenance Inspecting BurnersTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Wiring Diagram Service HintsSpecifications Technical ServiceReplacement Parts Parts Under WarrantyParts not Under Warranty Parts CentralAccessories Corner MantelGMC11F Series Walnut Finished Hardwood Veneer GMC13F Series Medium Stained Oak VeneerHAND-HELD Remote Control RM4 Blower Accessory GA3750 Series and GA3650T SeriesReceiver and HAND- Held Remote Control KIT Cghrc Series Equipment Shutoff Valve GA5010Illustrated Parts Breakdown Remote Ready Model LFP33PRAParts List KEY Part Number Description QTYFireplace LFP33PRA Parts List Warranty Information

LFP33PRA specifications

Desa LFP33PRA is a cutting-edge product that has gained attention for its advanced features and innovative technologies. This model stands out in the market for its combination of efficiency and user-friendly design, making it an ideal choice for a diverse range of applications.

One of the main highlights of the LFP33PRA is its robust performance. Equipped with a high-capacity energy storage system, it delivers reliable power support, ensuring that users experience minimal interruptions during operation. This is particularly beneficial for environments where continuous power supply is crucial, such as in industrial settings or for emergency backup purposes.

The incorporation of state-of-the-art lithium iron phosphate (LiFePO4) battery technology sets the LFP33PRA apart from traditional battery systems. This technology not only enhances the longevity of the unit but also contributes to its safety profile. LiFePO4 batteries are known for their thermal stability and higher resistance to overheating, making them a safer choice for users.

Another key characteristic of the Desa LFP33PRA is its impressive energy density. This feature allows the device to store more energy in a smaller, lighter package. As a result, it is easier to transport and install, further increasing its versatility across various sectors. The compact design does not compromise on power output, ensuring high efficiency for all applications.

In terms of technology integration, the LFP33PRA comes with smart monitoring capabilities. Users can conveniently track energy consumption, battery status, and overall performance through a digital interface, allowing for proactive maintenance and optimization of power usage. This feature is particularly advantageous for businesses that prioritize energy management and cost-efficiency.

The design of the LFP33PRA also emphasizes sustainability. By utilizing green technology in its manufacturing process and promoting energy savings during operation, the product aligns with eco-friendly initiatives. This dedication to sustainability resonates well with consumers who are increasingly conscious of their environmental impact.

Overall, the Desa LFP33PRA is a pioneering product that combines innovative technologies, safety, efficiency, and sustainability. Its advanced features and reliable performance make it a valuable addition to both commercial and residential power solutions. Whether for backup power or as a primary energy source, the LFP33PRA is equipped to meet the demands of modern electrical systems.