Desa LFP33PRA installation manual Ventilation AIR, Ventilation Air From Inside Building

Page 6

LFP33PRA

UNVENTED PROPANE/LP GAS FIREPLACE

AIR FOR COMBUSTION AND VENTILATION

Continued

Ventilation

Grills

Into Adjoining

12"

Ventilation Grills Into Adjoining Room,

VENTILATION AIR

Room,

Or

Option 2

Option 1

Remove

Ventilation Air From Inside Building

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 3). You can also remove door into adjoining room (see op- tion 3, Figure 3). Follow the National Fuel Gas Code, NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

WARNING: Rework work- sheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces.

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two per- manent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.

Door into Adjoining Room, Option 3

12"

Figure 3 - Ventilation Air from Inside Building

Ventilated

Outlet Attic

Air

Outlet

 

Air

To Attic

 

To

Crawl

Space

Inlet

Air

Inlet Air

 

Ventilated

 

 

Crawl Space

 

 

Figure 4 - Ventilation Air from Outdoors

6

107064

Image 6
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASShown with optional cabinet Mantel and hearth base Safety Information LFP33PRA Unvented PROPANE/LP GAS FireplaceLocal Codes Remote Control AccessoriesProduct Identification UnpackingProduct Features AIR for Combustion and VentilationAIR for Combustion Ventilation Determining FRESH-AIR Flow for Fireplace LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Check GAS Type InstallationOptional GA3750 Blower Accessory Electrical HookupInstallation Clearances Conventional Fireplace InstallationBUILT-IN Fireplace Installation Location of Nailing FlangesInstallation Items Needed Installing GAS Piping toMantel Clearances for Built-In Installation Fireplace LocationConnecting Fireplace to GAS Supply Gas ConnectionPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections Installing Logs Installing ScreenInstalling Remote Receiver Unit Optional Wireless HAND- Held Remote Control Accessory RM4Installing Batteries for RM4 Installing Batteries in ReceiverInstalling Battery in Hand-Held Remote Control Unit Installing Batteries for Cghrc and Cghrct SeriesInstalling Battery in Receiver Cghrct SeriesFor Your Safety Read Before Lighting Operating FireplaceLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Remote Operation Optional Blower OperationCleaning and Maintenance Inspecting BurnersTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Specifications Wiring DiagramService Hints Technical ServiceParts not Under Warranty Replacement PartsParts Under Warranty Parts CentralGMC11F Series Walnut Finished Hardwood Veneer AccessoriesCorner Mantel GMC13F Series Medium Stained Oak VeneerReceiver and HAND- Held Remote Control KIT Cghrc Series HAND-HELD Remote Control RM4Blower Accessory GA3750 Series and GA3650T Series Equipment Shutoff Valve GA5010Illustrated Parts Breakdown Remote Ready Model LFP33PRAParts List KEY Part Number Description QTYFireplace LFP33PRA Parts List Warranty Information

LFP33PRA specifications

Desa LFP33PRA is a cutting-edge product that has gained attention for its advanced features and innovative technologies. This model stands out in the market for its combination of efficiency and user-friendly design, making it an ideal choice for a diverse range of applications.

One of the main highlights of the LFP33PRA is its robust performance. Equipped with a high-capacity energy storage system, it delivers reliable power support, ensuring that users experience minimal interruptions during operation. This is particularly beneficial for environments where continuous power supply is crucial, such as in industrial settings or for emergency backup purposes.

The incorporation of state-of-the-art lithium iron phosphate (LiFePO4) battery technology sets the LFP33PRA apart from traditional battery systems. This technology not only enhances the longevity of the unit but also contributes to its safety profile. LiFePO4 batteries are known for their thermal stability and higher resistance to overheating, making them a safer choice for users.

Another key characteristic of the Desa LFP33PRA is its impressive energy density. This feature allows the device to store more energy in a smaller, lighter package. As a result, it is easier to transport and install, further increasing its versatility across various sectors. The compact design does not compromise on power output, ensuring high efficiency for all applications.

In terms of technology integration, the LFP33PRA comes with smart monitoring capabilities. Users can conveniently track energy consumption, battery status, and overall performance through a digital interface, allowing for proactive maintenance and optimization of power usage. This feature is particularly advantageous for businesses that prioritize energy management and cost-efficiency.

The design of the LFP33PRA also emphasizes sustainability. By utilizing green technology in its manufacturing process and promoting energy savings during operation, the product aligns with eco-friendly initiatives. This dedication to sustainability resonates well with consumers who are increasingly conscious of their environmental impact.

Overall, the Desa LFP33PRA is a pioneering product that combines innovative technologies, safety, efficiency, and sustainability. Its advanced features and reliable performance make it a valuable addition to both commercial and residential power solutions. Whether for backup power or as a primary energy source, the LFP33PRA is equipped to meet the demands of modern electrical systems.