OPERATING FIREPLACE For Your Safety Read Before Lighting Lighting Instructions To Turn off Gas to Appliance

Optional Remote Operation

17

OPERATING FIREPLACE

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.

A.This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire de- partment.

C.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

NOTICE: During initial operation of new heater, burn- ing logs will give off a paper-burning smell. Orange flame will also be present. Open damper or window to vent smell. This will only last a few hours.

1.STOP! Read the safety information, above.

2.Turn off all electric power to the appliance.

3.Turn wall switch to the OFF position.

4.Fully open glass doors if installed.

5.Remove front refractory brick access panel.

6. Turn equipment shutoff valve clockwise Clockwise to the OFF position (see Figure 37). Do not force.

7.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information. If you don’t smell gas, go to the next step.

8.Turn equipment shutoff valve counterclockwise C-clockwiseto the ON position. Do not force.

9.Replace front refractory brick access panel.

10.Fully close glass doors if installed.

11.Turn on all electric power to the appliance.

12.Turn the wall switch to the ON position.

13.Visually locate the pilot. The ignitor should begin to spark and the main burner should ignite once flame appears at pilot.

If lighting the appliance for the first time each season, it may take several attempts before the supply gas can reach the pilot and main burners.

If the appliance will not stay lit after several attempts, follow the instructions To Turn Off Gas To Appliance, below, and call your service technician or gas supplier.

Equipment Shutoff Valve

Adjustment

 

Screw

Figure 37 - Turning Equipment Shutoff Valve to the OFF Position

TO TURN OFF GAS

TO APPLIANCE

1.Turn off the wall switch.

2.Turn off all electric power to the appliance if service is to be performed.

3.Fully open glass doors if installed.

4.Remove front hearth brick and control access panel.

5. Turn equipment shutoff valve clockwise Clockwise to OFF.

Do not force.

6.Replace front refractory brick access panel.

7.Fully close glass doors if installed.

Sensing Rod

Pilot Burner

Ignitor

Figure 38 - Pilot

OPTIONAL REMOTE

OPERATION

Note: The WRC receiver and hand-held remote control kit must be purchased separately (see Accessories, page 25). Follow installation instructions on page 11.

1.Turn equipment shutoff valve to ON position.You can now turn the burner on and off with the hand-held remote control unit. IMPORTANT: Be sure to press the ON/OFF buttons on the hand-held remote control unit for up to 3 seconds to assure proper operation.

2.Press the ON/OFF button to turn the burner on and off.

For more information, visit www.desatech.com

108796-01D

Image 17
Contents Vent Decorative GAS Fireplace For Your SafetyElectronic Ignition Natural GAS What to do if YOU Smell GASSafety Information Table of ContentsUnpacking M36EB,H/VM36EB,H M42EB,H/VM42EB,H IntroductionBefore YOU Begin Model Product SpecificationsClearances PRE-INSTALLATION PreparationSelecting Location M36EB,H M42EB,H Mantel Clearances and Wall DetailsVM36EB,H VM42EB,H M36EB,H M42EB,H VM36EB,H VM42EB,HFraming Installing Transition Pipe and Starter CollarTypical B-Vent Configuration Venting InstallationMin Roof Pitch Checking for Proper VentingWall Switch Installation InstallationOptional Remote Control GAS Line HOOK-UPOvertighten Ember and PAN Material PlacementInstalling Logs 1 LOG Placement for M36E/VM36E ModelsInstalling Logs 1A, 1B LOG Placement for M42E/VM42E ModelsAppliance Enclosure Installing Optional Glass Door AccessoryCombustion AIR KIT Model AK4 Optional Door Opening Vent DamperOperating Fireplace For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To ApplianceInspecting Burners Cleaning MaintenanceTechnical Service Service HintsWiring Diagram Replacement PartsObserved Problem Possible Cause Remedy TroubleshootingGas leak. See Warning statement at TopVM42EB,H Models Illustrated Parts BreakdownVM36EB/VM42EB Parts ListLogset for M36EB,H and VM36EB,H Models Logs for M36EB,H,M42EB,H, VM36EB,H and VM42EB,H ModelsAccessories Warranty Information

M36E, M42E, VM36E, VM42E, H) AND VM42E(B specifications

Desa M36E, M42E, VM36E, VM42E(H), and VM42E(B) are advanced heating solutions engineered for enhanced performance and versatility in both residential and commercial settings. These models stand out for their efficient heating capabilities and innovative designs, which cater to a variety of heating needs.

The Desa M36E and M42E models offer a robust heating output, making them ideal for larger spaces. The M36E boasts a compact structure that accommodates small to medium areas, while the M42E provides greater output suitable for bigger rooms. Both units are equipped with high-efficiency burners that ensure optimal fuel utilization, leading to significant cost savings over time.

The VM36E and VM42E(H) models take efficiency to the next level. Their advanced combustion technology maximizes heat production while minimizing emissions, aligning with modern environmental standards. The VM36E features a versatile design, allowing it to seamlessly integrate into various décor styles, while providing a steady flow of warm air. Meanwhile, the VM42E(H) is enhanced with a hybrid heating system, enabling users to switch between energy sources, which adds to its adaptability in differing climates or situations.

The VM42E(B) model introduces an innovative breakthrough in heating technology by incorporating smart control features. Users can effortlessly regulate their heating preferences through a smartphone application, allowing for remote management and programming based on individual schedules. This smart technology not only enhances user convenience but also supports energy conservation by promoting efficient usage patterns.

All models come equipped with safety features such as automatic shut-off mechanisms, ensuring peace of mind during operation. The units are designed with durable materials, capable of withstanding prolonged use while maintaining aesthetic appeal.

In summary, Desa's M36E, M42E, VM36E, VM42E(H), and VM42E(B) represent the forefront of modern heating solutions, combining high efficiency, innovative technologies, and user-friendly features. Their diverse applications, coupled with intelligent design, ensure they meet the evolving demands of today's consumers while providing warmth and comfort in any setting.