Desa (V)T32P-A SERIES, (V)T32N-A SERIES Model BKT Installation, Blower see Figure

Page 17

FIREPLACE INSTALLATION

Installing Optional Blower Accessories (Cont.)

17

FIREPLACE INSTALLATION

Continued

5.Mount speed control box to switch bracket by placing the plastic control shaft forward through the round opening in the switch bracket (see Figure 26).

6.While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against front panel. Place control knob provided on shaft.

7.Turn on power to duplex outlet if previously turned off per the warning in column 2, page 16.

8.Plug in blower power cord.

a.If your firebox is installed as a freestanding unit with an accessory mantel, determine whether the power cord will exit the left side or the right side of the firebox. Route power cord through exit hole and plug the power cord into a wall receptacle near the firebox.

b.If your firebox installation is recessed and/or pre-wired, plug the power cord into the duplex outlet provided. Refer to your firebox ownerʼs manual for instructions on wiring the duplex outlet.

CAUTION: Never touch the blower wheel while in operation.

9.

Check to make sure that the power cord is completely clear of the

 

blower wheel and that there are no other foreign objects in blower

 

wheel. Turn blower on and check for operation. Turn blower off

 

by turning knob fully counterclockwise before continuing.

Model BKT Installation

Note: When installing the BKT thermostatically-controlled blower, you must first secure the thermal switch bracket to the blower if it has not already been factory installed.

1.Place the green ground wire with ring terminal between the bottom hole on the thermal switch bracket and the top ear hole on the blower assembly. Insert the phillips screw into all three pieces and tighten securely (see Figure 28).

2.Connect wire harness and power cord terminals. Connect the blue jumper wire to the blower motor terminal and the right side terminal of the thermal switch. Connect the black wire to the left side of the thermal switch and the white wire to the other remaining blower motor terminal.

Note: The power cord outer insulation sleeve may have to be stripped slightly to allow enough wire length to reach and make all connections. DO NOT trim excessive length away. Just enable enough to make all connections securely.

3.Place the blower against the lower rear wall of the firebox outer wrapper with the exhaust port directed upward and the thermodisc positioned up near the fireplace bottom. The thermodisc must be oriented near the fireplace bottom as shown in Figure 28 in order to sense temperature and properly operate. The blower will be held in position against the back wall by the magnets incorporated onto the blower housing (see Figure 28).

4.Be certain that all wire terminals are securely attached to ter- minals on blower motor and thermal switch and that the screw for the thermodisc bracket and green ground wire is tight.

10. Peel off the backing paper and stick the supplied wiring diagram

decal on the firebox bottom approximately 12" in front of the

blower (see Figure 27).

Switch

Speed Control

 

Bracket

Blower

 

Plug-In

 

Control

Duplex Outlet

Control

(Located underneath

Power Cord

Thermal

Switch

Bracket

Black

Wire

Phillips Screw

Thermal Switch

White Wire

 

Blue Wire

Magnetic

 

Strips

Air Flow

 

Direction

 

Ring Terminal on Green Wire

Knob

Locknut

Shaft

firebox floor against

 

 

 

lower right outside wall)

Figure 26 - Attaching Speed Control to Firebox

Wiring Diagram Decal

12" in Front of Blower

Figure 27 - Location of Wiring Diagram Decal (Model May Vary From Illustration)

Route BKT

 

Blower Through

Thermodisc

This Area

 

Side View Firebox Bottom

Figure 28 - Blower Model BKT

Air Flow Direction Magnets

Blower

Location

116646-01B

www.desatech.com

Image 17
Contents For Your Safety OWNER’S Operation Installation ManualFor Your Safety What to do if YOU Smell GAS Save this manual for future referenceSafety Information Table of ContentsLocal Codes Safety Information Product IdentificationLocation and Space Requirements Product FeaturesPRE-INSTALLATION Preparation Framing and Finishing ClearancesTermination CAP AIR Supply Inlet GAS Meter Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Siding Standoff Combustible Horizontal Termination Configurations MaintenanceCap must be removable for vent inspection VerticalCorner Installation Venting with Two 90 Elbows Horizontal System Installation Using TWO ElbowsFlat Ceiling Installation Installation for Vertical TerminationVenting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting High Altitude InstallationFireplace Installation Venting InstallationInstalling Optional Blower Accessories Check GAS TypeBlower see Figure Model BKT InstallationInstallation Items Needed Installing GAS Piping to Fireplace LocationBlower Wiring Diagram Or servicing. Correct all leaks at once Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing Fireplace Gas Connections Installing Optional Wall Mount Switch GWMS2Installing 9-Volt Alkaline Battery in Hand-Held Installing Remote ReceiverRemote Control Unit Removing Louver PanelsRemoving Glass Door Installing Optional Brick Liner Model BL32DCleaning Glass Door Installing Side Brick Panels Installing LOGS, Lava Rock and Glowing EmbersLighting Instructions For Your Safety Read Before LightingOperating Fireplace To Turn OFF GAS To Appliance Manual Lighting ProcedureOptional HAND-HELD Remote Operation Shutting Off Burners Only pilot stays litThermostat Series ON/OFF SeriesPilot Assembly Operating Optional Blower AccessoryInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatGlass Door Cleaning and MaintenancePilot and Burners LogsObserved Problem Possible Cause Remedy TroubleshootingInlet gas pressure is too low Above Gas leak. See Warning statementCGDV32NR CGDV32PR Illustrated Parts BreakdownParts List Parts ListService Hints Replacement PartsTechnical Service SpecificationsOwners Registration Form Postage Required Accessories Keep this Warranty Warranty Information

(V)T32P-A SERIES, (V)T32N-A SERIES, T32N-A, CGDV32NR, T32P-A, CGDV32PR specifications

The T32N-A, CGDV32NR, T32P-A, CGDV32PR, (V)T32P-A SERIES, and (V)T32N-A SERIES are distinguished series of innovative technologies designed to meet diverse industrial demands. These models exemplify cutting-edge engineering, tailored for performance, efficiency, and adaptability.

One of the primary features of these series is their robust construction. The T32N-A and its counterparts are built with high-quality materials, ensuring durability and longevity even in harsh operating conditions. This reliability makes them ideal for applications that require consistent performance under stress. The engineering design incorporates advanced computational techniques, resulting in streamlined shapes that enhance aerodynamic efficiency.

The CGDV32NR and CGDV32PR series are particularly notable for their fluid management capabilities. These models are equipped with sophisticated flow control technologies that optimize the movement of fluids, minimizing waste and energy consumption. This efficiency is crucial for industries such as water treatment, chemical processing, and food production, where resource conservation is paramount.

Additionally, the (V)T32P-A and (V)T32N-A SERIES introduce variable technology options, allowing for enhanced versatility in operation. These models feature adjustable parameters that can be fine-tuned to suit specific processes, making them adaptable for various industrial applications. This flexibility minimizes downtime and maximizes productivity, providing a significant competitive edge.

In terms of user interface, these series emphasize user-friendly controls and robust monitoring systems. Operators can easily track performance metrics and make real-time adjustments, ensuring optimal functionality. Advanced sensors integrated into the systems enhance safety by providing alerts and diagnostics that preempt potential issues.

Environmental considerations are also a critical focus of these series. The T32N-A and associated models are designed with energy efficiency in mind, aligning with contemporary sustainability goals across industries. Reduced energy consumption and lower emissions are significant advantages, contributing to a smaller ecological footprint.

Overall, the T32N-A, CGDV32NR, T32P-A, CGDV32PR, (V)T32P-A SERIES, and (V)T32N-A SERIES stand out for their exceptional features, intuitive technology, and adaptability. Suitable for various industrial applications, they represent the forefront of innovation, combining performance and efficiency to meet the evolving demands of modern industry. As businesses continue to prioritize reliability and sustainability, these series are poised to play a critical role in driving progress across sectors.