INSTALLING GAS LINE

INSTALLATION

Installing Gas Line Installing Fireplace Hood and Screen

11

INSTALLATION

Continued

INSTALLING GAS LINE

Figure 11 - Location of Knockout for Gas Line WARNING: A qualified service person must con- nect heater to gas supply. Follow all local codes.

IMPORTANT: See Connecting to Gas Supply in your log set owner’s manual for details on gas hookup.

You may run the gas line from either side of the firebox (see Figure 11). Decide which side you want to run the gas line from.

Note: This is one option for installing shutoff valve. Check local codes for equipment shutoff valve location requirements.

Locate the recessed knockout in one of the firebrick sidewall liners (see Figures 10 and 11). Firmly tap the center of the knockout with a chisel until it is released. Carefully chisel the rough edges of the hole you have made to smooth edges. This hole will line up with the hole in the outer casing.

Locate the recessed knockout in one of the firebrick sidewall liners (see Figures 10 and 11). Firmly tap the center of the knockout with a chisel until it is released. Carefully chisel the rough edges of the hole to smooth edges. This hole will line up with the hole in the outer casing.

INSTALLING FIREPLACE HOOD AND SCREEN CAUTION: Do not use excessive force to remove the knockout. Too much force may damage the fire- brick concrete insert.

13/8" Thick Liner

Firebrick Side Wall

Side

Figure 12 - Screw and Hood Placement View

Remove

(Model May Vary From Illustration) this Area

KnockoutChisel

Figure 11 - Location of Knockout for Gas Line

INSTALLING FIREPLACE HOOD AND SCREEN

1.Attach hood to firebox using screws provided (see Figure 12).

2.Insert each rod through all rings located at top of screen.

3.Insert first rod into rear hole in left side of firebox. Fasten rod to rear hole near center of firebox using #10 x 3/8" Phillips screw provided (see Figure 13).

4.Insert other rod into front hole on right side of firebox and fasten using remaining Phillips screw.

Knockout Locations

(Knock Out One Hole)

Gas Line Hole

Equipment

 

Shutoff

Screws

Valves

 

(Install

 

One)

Figure 12 - Screw and Hood Placement

 

Rear Hole

Front Hole

Rod

Top View of

Rod Layout

Figure 10 - Installing Gas Line and Equipment Shutoff Valve

 

(Model May Vary From Illustration)
Ring

 

 

Screen

 

Screw

 

Figure 13 - Installing Fireplace Screen

RingFor moreScreenScrewFigure 13 - Installing Fireplace Screenvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

110749-01A

Image 11
Contents V50S, V50SH, and VFB50NC Vent-FreeFireboxes UNVENTED VENT-FREE UNIVERSAL FIREBOXSave this manual for future TM OWNER’S OPERATION AND INSTALLATION MANUALWARNINGS TABLE OF CONTENTSSAFETY INFORMATION Continued PRODUCT FEATURESLOCAL CODES LOCATING FIREBOXFirebox Top View PRODUCT SPECIFICATIONSPRODUCT SPECIFICATIONS Figure 1 - Firebox DimensionsPROVIDING ADEQUATE VENTILATION AIR FOR COMBUSTION AND VENTILATIONAIR FOR COMBUSTION AND VENTILATION AIR FOR COMBUSTION AND VENTILATIONContinued Ventilation Air From Inside Building AIR FOR COMBUSTION AND VENTILATIONContinued VENTILATION AIRINSTALLATION CLEARANCES INSTALLATIONContinued INSTALLATIONBUILT-INFIREBOX INSTALLATION Mantel Clearances for Built-InInstallation1.Assemble cabinet mantel as instructed INSTALLATIONContinued INSTALLATION INSTALLATIONINSTALLING GAS LINE INSTALLING FIREPLACE HOOD AND SCREEN11 12 ILLUSTRATED PARTS BREAKDOWNILLUSTRATED PARTS BREAKDOWN 24 25 23 38 32 36 37PART PARTS LISTPARTS LIST PARTH50B - 50 Hood - Brushed Brass TECHNICAL SERVICEACCESSORIES REPLACEMENT PARTSOWNERS REGISTRATION FORM 2701 Industrial Drive P.O. Box Bowling Green, KY Postage RequiredTAPE TAPEPage 2701 Industrial Drive P.O. Box Bowling Green, KY WARRANTY INFORMATIONNOT A UPC Model Serial No Date Purchased