Desa VCGF30PR installation manual Unvented PROPANE/LP GAS Fireplace, Safety Information

Page 2

®

UNVENTED PROPANE/LP GAS FIREPLACE

SAFETY

INFORMATION

WARNINGS

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace. Improper use of this fireplace can cause seri- ous injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the fireplace may not be working properly. Get fresh air at once! Havefireplaceserviced.Somepeoplearemore affectedbycarbonmonoxidethanothers.These include pregnant women, people with heart or lung disease or anemia, those under the influ- ence of alcohol, and those at high altitudes.

Propane/LP Gas: Propane/LP gas is odor- less. An odor-making agent is added to the gas. The odor helps you detect a gas leak. How- ever, the odor added to the gas can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.

WARNING: Any change to this heater or its controls can be dangerous.

WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.

WARNING: Do not use a blower insert, heat exchanger insert or other accessory not ap- proved for use with this fireplace.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Fireplace front becomes very hot when running fireplace. Keep chil- dren and adults away from hot sur- faces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shutdown. Allow surfaces to cool before touching.

Carefully supervise young chil- dren when they are in the room with fireplace. When using the hand-held remote accessory, keep selector switch in the OFF position to prevent children from turning on burners with remote.

You must operate this fireplace with the front window assembly and hood in place. Make sure front window assembly and hood are in place before running fireplace.

Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) inside any structure. Locate propane/ LP supply tank(s) outdoors.

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

4.This fireplace shall not be installed in a bedroom or bathroom.

5.Do not use this fireplace as a wood- burning fireplace. Use only the logs provided with the fireplace.

6.Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of fireplace.

7.This fireplace is designed to be smoke- less. If logs ever appear to smoke, turn off fireplace and call a qualified ser- vice person. Note: During initial op- eration, slight smoking could occur due to log curing and fireplace burning manufacturing residues.

8.To prevent the creation of soot, follow the instructions in Cleaning and Main- tenance, page 21.

9.Before using furniture polish, wax, car- pet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white pow- der residue within burner box or on ad- jacent walls or furniture.

10.This fireplace needs fresh air ventila- tion to run properly. This fireplace has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the fireplace if not enough fresh air is available. See Air for Combus- tion and Ventilation, pages 4 through 6. If fireplace keeps shutting off, see Troubleshooting, pages 17 through 19.

11.Do not run fireplace

• where flammable liquids or vapors are used or stored

• under dusty conditions

12.Do not use this fireplace to cook food or burn paper or other objects.

13.Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control system and any gas control which has been under water.

14.Do not operate fireplace if any log is broken. Do not operate fireplace if a log is chipped (dime-sized or larger).

15.Turn fireplace off and let cool before servicing. Only a qualified service per- son should service and repair fireplace.

2

104637

Image 2
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASSafety Information Unvented PROPANE/LP GAS FireplaceLocal Codes Remote Control AccessoriesProduct Identification UnpackingProduct Features AIR for Combustion and VentilationDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Building Ventilation AIRVentilation Air From Inside Ventilation Air From OutdoorsCheck GAS Type InstallationInstalling Deflector and Hood Electrical HookupInstallation Clearances Conventional Fireplace InstallationBUILT-IN Fireplace Installation Location of Nailing FlangesInstallation Items Needed Mantel Clearances for BUILT-IN InstallationInstalling GAS Piping to Fireplace Location Connecting Fireplace to GAS Supply Attaching Flexible Gas Lines TogetherChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Installing Logs Will create sootLighting Instructions For Your Safety Read Before LightingOperating Fireplace Optional Remote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Pilot Flame Pattern Inspecting BurnersOptional Blower Operation Burner Primary AIR HolesTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Service Hints Wiring Diagram Replacement PartsSpecifications Technical ServiceLogs Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Front Window GlassAccessories WALL-MOUNT Thermostat Switch GWMT1 Cleaning KIT CCKReceiver and HAND-HELD Remote Control KIT Ghrc Series WALL-MOUNT ON/OFF Switch GWMS2Illustrated Parts Breakdown Remote Ready Catalytic Model VCGF30PRParts List KEY Part Number Description QTYFireplace VCGF30PR Parts List Warranty Information

VCGF30PR specifications

The Desa VCGF30PR is an advanced gas fireplace designed for both aesthetic appeal and functional efficiency. This model stands out in the market for its combination of modern technology, sleek design, and user-friendly features, making it an excellent choice for homeowners seeking an elegant heating solution.

One of the standout features of the VCGF30PR is its impressive heating capacity. Designed to warm spaces effectively, it can heat an area of around 1,200 square feet, making it ideal for living rooms, dens, and other large spaces in the home. The fireplace operates on natural gas or propane, providing flexibility depending on the homeowner's needs and preferences.

The unit boasts a stunning ceramic glass front, allowing for a clear view of the flames while minimizing heat loss. This design not only enhances the aesthetic appeal of the fireplace but also aids in energy efficiency. The use of advanced technology ensures that the flames are realistic and comforting, creating the perfect ambiance for any occasion.

One of the significant technological advancements in the VCGF30PR is its electronic ignition system. This feature enables quick and hassle-free startups with just the push of a button. The unit is also equipped with a built-in blower, which helps circulate warm air throughout the room, enhancing heating efficiency and comfort.

Safety is a priority with the Desa VCGF30PR. The fireplace includes a built-in safety shut-off valve that automatically cuts the gas supply in case of any irregularities, providing peace of mind for users. Additionally, it features a thermostat control, allowing homeowners to set their desired temperature for optimal comfort without constant monitoring.

The VCGF30PR also incorporates easy maintenance features. Its design allows for straightforward cleaning and upkeep, ensuring that it remains a captivating focal point in any home for years to come. The variety of finish options available—such as brushed nickel, black, or traditional bronze—allows homeowners to customize the look of their fireplace to match their interior décor.

In conclusion, the Desa VCGF30PR gas fireplace combines modern technology, safety features, and beautiful design elements, making it a remarkable addition to any home. With its efficient heating capabilities, user-friendly operation, and elegant appearance, it promises both comfort and style for years to come.