INSTALLATION

WALL AND CEILING PROTECTION

HORIZONTAL VENT SECTIONS: A minimum clearance of 2" all around the vent pipe in all horizontal runs to combustibles is required. Use fi restop spacer W010-1778 (supplied).

VERTICAL VENT SECTIONS: A minimum of 1" all around the vent pipe on all vertical runs to combustibles is required. Use fi restop spacer W500-0028 (not supplied).

VENT HEAT SHIELD INSTALLATION

The vent heat shield must be

FIGURE 15installed only when terminat- ing horizontally with no vertical

rise. Remove the two screws nearest the vent collars on the top of the fi replace. Align the vent heat shield (sup- plied) and secure. Adjust the vent heat shield to touch the fi restop spacer.

HORIZONTAL INSTALLATION

This application occurs when venting through an exterior wall. Having deter- mined the air terminal location, cut and frame a hole in an exterior wall. The recommended framed opening is 147/16" W x 161/4" H. See figure16.

FIGURE 16

ADJUSTABLE FIRESTOP INSTALLATION

Apply a bead of caulking all around and place the fi restop top, so that the vent shield covers the top of the vent within the opening.

NOTE: THE FIRESTOP ASSEMBLY MUST BE INSTALLED WITH THE VENT SHIELD TO THE TOP.

The length of the vent shield may be cut shorter for combustible walls that are less than 8 1/2" thick but the vent shield must extend the full depth of the combustible wall.

Place the fi restop bottom against the fi restop top and secure the two together. Adjust the assembly to ensure it is tight to the vent. Secure fi restop to wall. This restricts cold air from being drawn into the room or around the fi replace. Ensure that both spacer and shield maintain the required clearance to combustibles. Once the vent pipe is installed in its fi nal position, apply high temperature sealant W573-0002 (not supplied) between the pipe and the fi re- stop spacer. See figures 17a-c.

VENT

SHIELD

FIRESTOP

TOP

FIGURE 17a

FIRESTOP

BOTTOM

FIGURE 17b

FIGURE 17c

VERTICAL INSTALLATION

This application occurs

 

when venting through

 

a roof. Installation kits

FIGURE 18

for various roof pitches

 

are available from your

 

Continental® dealer. See

 

Accessories to order the

 

specifi c kit required.

 

1.Determine the air terminal location, cut and frame

123/4" x 123/4" openings in the ceiling and the roof to provide the minimum 1" clearance between the fi replace pipe / liner and any

combustible material. Try

FIGURE 19

to centre the vent pipe loca-

 

tion midway between two

 

joist to prevent having to

 

cut them. Use a plumb bob

 

to line up the centre of the

 

openings. DO NOT FILL

 

THIS SPACE WITH ANY TYPE OF MATERIAL.

A vent pipe shield will

prevent any materials such as insulation, from fi lling up the 1" air space around the pipe. Nail headers between the joist for extra support.

2.Apply a bead of caulking (not supplied) to the framework or to the Wolf Steel vent pipe shield plate or equivalent (in the case of a fi nished ceiling), and secure over the opening in the ceiling. FIGURE 19. A firestop must be placed on the bottom of each framed opening in a roof or ceiling that the venting system passes through. Apply a bead of caulking all around and place a fi restop spacer over the vent shield to restrict cold air from being drawn into the room or around the fi replace. Ensure that both spacer and shield maintain the required clearance to combustibles. Once the vent pipe / liner is installed in its fi nal position, apply sealant between the pipe / liner and the fi restop spacer.

W415-0327 / B / 12.07.07

Image 14
Contents W415-0327 / B $10.00 Table of Contents Conditions and Limitations Care of GLASS, and Plated Parts General InstructionsGeneral Information Installation Overview Supplier VentingVenting Lengths Minimum AIR Terminal Location Clearances Special Vent Installations Periscope TerminationVertical rise is less than horizontal run Venting Application Flow ChartVertical Termination Definitions When HT VTHorizontal Termination Elbow Vent Length ValuesFormula 1 HT 4.2 VT Formula 2 HT + VT 24.75 feet = HR + HO = 5.5 + 5.4 = 10.9 ft Vertical Termination= .0345+90+90+90-135=5.4 = 10.9 + 15 = 25.9 ft+ V T = 13.4 + 2.5 = 15.9 ft = .0345 + 90 + 90 + 90 135 = 5.4 ft= H R + H O = 8 + 5.4 = 13.4 ft 3V TVertical Installation Installation Wall and Ceiling ProtectionHorizontal Installation Vent Heat Shield InstallationUsing Flexible Vent Components Fireplace Vent ConnectionRestricting Vertical Vents Using Rigid Vent ComponentsVertical Venting Installation Mobile Home Installation GAS InstallationOptional Wall Switch Installation FramingMinimum Mantel and Enclosure Clearances From bottom of unit 84 from bottom of unitFinishing Nailing TAB InstallationLOG Placement / Glowing Embers Glowing Embers Logo PlacementCharcoal Embers Louvre Installation VermiculiteGD36 Thermostatic Sensor Control Optional Blower InstallationOptional FAN Installation Operating Instructions Operation / MaintenanceMaintenance FireplaceVenturi Adjustment AdjustmentsPilot Burner Adjustment Front RearAccessories ReplacementsReplacement Parts Flexible Vent Kits Roof Terminal KitsW415-0327 / B Trouble Shooting Guide Symptom Problem Test SolutionWise Firmly to RESEAL. do not Overtorque W415-0327 / B

BCDV48N, BCDV48P specifications

The Continental BCDV48P and BCDV48N are cutting-edge commercial vehicles designed to meet the needs of modern logistics and transportation. Both models showcase Continental's commitment to engineering excellence, offering a blend of advanced technologies, safety features, and performance characteristics.

The BCDV48P primarily focuses on urban delivery scenarios, making it ideal for navigating congested city streets. Its compact design enables agile maneuverability, while the spacious cargo area ensures it can accommodate a variety of freight types. The BCDV48N, on the other hand, is designed for slightly heavier loads, featuring enhanced payload capacity while retaining a similar compact footprint.

One of the standout features of both models is the innovative electric drive system. This powertrain technology not only reduces emissions but also enhances energy efficiency, making them environmentally friendly options for businesses looking to lower their carbon footprint. The low noise operation of the electric drive offers a distinct advantage in urban environments, allowing for quiet deliveries even in residential areas.

Safety is paramount in the BCDV48P and BCDV48N. Both vehicles come equipped with an array of advanced safety systems, including electronic stability control and anti-lock braking systems. Additionally, features such as rearview cameras and parking sensors facilitate easy navigation and parking, contributing to overall operational safety.

Technologically, the BCDV models are equipped with a state-of-the-art infotainment system that provides real-time navigation and connectivity features. Fleet managers can track vehicle performance, monitor energy consumption, and optimize routes through integrated telematics, significantly enhancing operational efficiency.

The ergonomic design of the driver’s cabin focuses on comfort and functionality. With spacious seating, adjustable steering, and a user-friendly dashboard layout, drivers can maintain high levels of productivity throughout their shifts. Ample storage compartments ensure that essential tools and equipment are within easy reach.

In summary, the Continental BCDV48P and BCDV48N are versatile vehicles that blend advanced technologies with practical features. Their commitment to sustainability, safety, and user experience makes them ideal choices for businesses looking to optimize their logistics operations while minimizing their impact on the environment. These models stand as a testament to Continental's innovation in the commercial vehicle segment.