OPERATION / MAINTENANCE

OPERATING INSTRUCTIONS

When lit for the fi rst time, the fireplace will emit a slight odour for a few hours. This is a normal temporary condition caused by the curing of the logs and the "burn-in" of internal paints and lubricants used in the manufacturing process and will not occur again.

After extended periods of non-operation such as following a vacation or a warm weather season, the fi replace may emit a slight odour for a few hours. This is caused by dust particles in the heat exchanger burning off. In both cases, open a window to suffi ciently ventilate the room.

Purge the gas line with the glass door removed. Assure that a continuous gas flow is at the burner before reinstalling the door.

FOR YOUR SAFETY READ BEFORE LIGHTING:

A. This fi replace is equipped with a pilot which must be lit by hand while following these instructions exactly.

B. Before operating smell all around the fi replace area for gas and next to the fl oor because some gas is heavier than air and will settle on the fl oor

C. Use only your hand to turn the gas control knob. Never use tools. If the knob will not turn by hand, do not try to repair it. Call a quali-

fi ed service technician. Force or attempted repair may result in a fi re or explosion.

D.Do not use this fi replace if any part has been under water. Imme- diately call a qualifi ed service technician to inspect the fi replace and replace any part of the control system and any gas control which has been under water.

WHAT TO DO IF YOU SMELL GAS

• Turn off all gas to the fi replace.

• Open windows.

FIGURE 53

 

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neigh- GAS KNOB bour's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fi re department.

FIGURE 54

LIGHTING INSTRUCTIONS

WARNING: The gas valve has an interlock device which will not allow the pilot burner to be lit until the thermocouple has cooled. Allow approximately 60 seconds for the thermocouple to cool.

When lighting and relighting, the gas knob cannot be turned from pilot to off unless the knob is depressed slightly.

1.Stop! Read the above safety information on this label.

2.Turn off all electric power to the fi replace.

3.Turn the gas knob clockwise to off.

4.Wait five (5) minutes to clear out any gas. If you smell gas includ- ing near the fl oor. Stop! Follow "B" in the above safety information on this label. If you don't smell gas go the next step.

5. Turn gas knob counter-clockwise to pilot.

6.Depress slightly and hold gas knob while lighting the pilot with the push button igniter. Keep knob depressed for one minute, then release. If pilot does not continue to burn, repeat steps 3 through

7.With pilot lit, depress and turn gas knob counter-clockwise to

on.

8.If equipped with remote on-off switch/thermostat, main burner may not come on when you turn valve to on. Remote switch must be in the on position to ignite burner.

9.Turn on all electric power to the fi replace.

TO TURN OFF GAS

1.Turn off all electric power to the fi replace if service is to be 2. Push in gas control knob slightly and turn clockwise to off. Do

performed.

not force.

MAINTENANCE

 

3.

Check to see that all burner ports are burning. Clean out any of

Turn off the gas and electrical power before servicing the

the ports which may not be burning or are not burning properly.

fireplace.

4.

Check to see that the pilot fl ame is large enough to engulf the

CAUTION: Label all wires prior to disconnection when servicing

thermocouple and thermopile and reaches toward the burner with

controls. Wiring errors can cause improper and dangerous operation.

the third jet.

Verify proper operation after servicing. This fi replace and its venting

5.

Replace the cleaned logs.

system should be inspected before use and at least annually by a

6.

Check to see that the main burner ignites completely on all open-

qualifi ed service person. The fi replace area must be kept clear and

ings when the gas knob for the burner is turned on. A 5 to 10 second

free of combustible materials, gasoline or other fl ammable vapours

total light-up period is satisfactory. If ignition takes longer, consult

and liquids. The fl ow of combustion and ventilation air must not be

your Continental® dealer / distributor.

obstructed.

7.

Check that the gasketing on the sides, top and bottom of the door

is not broken or missing. Replace if necessary.

1. In order to properly clean the burner and pilot assembly, remove the logs to expose both assemblies.

2. Keep the control compartment, logs, burner, air shutter opening and the area surrounding the logs clean by vacuuming or brushing, at least once a year.

W415-0327 / B / 12.07.07

Image 22
Contents W415-0327 / B $10.00 Table of Contents Conditions and Limitations General Information General InstructionsCare of GLASS, and Plated Parts Installation Overview Venting Lengths VentingSupplier Minimum AIR Terminal Location Clearances Special Vent Installations Periscope TerminationVertical Termination Venting Application Flow ChartVertical rise is less than horizontal run Definitions When HT VTHorizontal Termination Elbow Vent Length ValuesFormula 1 HT 4.2 VT Formula 2 HT + VT 24.75 feet = HR + HO = 5.5 + 5.4 = 10.9 ft Vertical Termination= .0345+90+90+90-135=5.4 = 10.9 + 15 = 25.9 ft+ V T = 13.4 + 2.5 = 15.9 ft = .0345 + 90 + 90 + 90 135 = 5.4 ft= H R + H O = 8 + 5.4 = 13.4 ft 3V TVertical Installation Installation Wall and Ceiling ProtectionHorizontal Installation Vent Heat Shield InstallationUsing Flexible Vent Components Fireplace Vent ConnectionVertical Venting Installation Using Rigid Vent ComponentsRestricting Vertical Vents Mobile Home Installation GAS InstallationOptional Wall Switch Installation FramingMinimum Mantel and Enclosure Clearances From bottom of unit 84 from bottom of unitLOG Placement / Glowing Embers Nailing TAB InstallationFinishing Glowing Embers Logo PlacementCharcoal Embers Louvre Installation VermiculiteOptional FAN Installation Optional Blower InstallationGD36 Thermostatic Sensor Control Operating Instructions Operation / MaintenanceMaintenance FireplaceVenturi Adjustment AdjustmentsPilot Burner Adjustment Front RearAccessories ReplacementsReplacement Parts Flexible Vent Kits Roof Terminal KitsW415-0327 / B Trouble Shooting Guide Symptom Problem Test SolutionWise Firmly to RESEAL. do not Overtorque W415-0327 / B

BCDV48N, BCDV48P specifications

The Continental BCDV48P and BCDV48N are cutting-edge commercial vehicles designed to meet the needs of modern logistics and transportation. Both models showcase Continental's commitment to engineering excellence, offering a blend of advanced technologies, safety features, and performance characteristics.

The BCDV48P primarily focuses on urban delivery scenarios, making it ideal for navigating congested city streets. Its compact design enables agile maneuverability, while the spacious cargo area ensures it can accommodate a variety of freight types. The BCDV48N, on the other hand, is designed for slightly heavier loads, featuring enhanced payload capacity while retaining a similar compact footprint.

One of the standout features of both models is the innovative electric drive system. This powertrain technology not only reduces emissions but also enhances energy efficiency, making them environmentally friendly options for businesses looking to lower their carbon footprint. The low noise operation of the electric drive offers a distinct advantage in urban environments, allowing for quiet deliveries even in residential areas.

Safety is paramount in the BCDV48P and BCDV48N. Both vehicles come equipped with an array of advanced safety systems, including electronic stability control and anti-lock braking systems. Additionally, features such as rearview cameras and parking sensors facilitate easy navigation and parking, contributing to overall operational safety.

Technologically, the BCDV models are equipped with a state-of-the-art infotainment system that provides real-time navigation and connectivity features. Fleet managers can track vehicle performance, monitor energy consumption, and optimize routes through integrated telematics, significantly enhancing operational efficiency.

The ergonomic design of the driver’s cabin focuses on comfort and functionality. With spacious seating, adjustable steering, and a user-friendly dashboard layout, drivers can maintain high levels of productivity throughout their shifts. Ample storage compartments ensure that essential tools and equipment are within easy reach.

In summary, the Continental BCDV48P and BCDV48N are versatile vehicles that blend advanced technologies with practical features. Their commitment to sustainability, safety, and user experience makes them ideal choices for businesses looking to optimize their logistics operations while minimizing their impact on the environment. These models stand as a testament to Continental's innovation in the commercial vehicle segment.