Desa VSGF36PR, VSGF36NT, VSGF36PT, VSGF36NR Installation Items Needed, Natural Gas, Propane/LP

Page 14

INSTALLATION

Continued

WARNING: Never connect natural gas fireplace to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

Installation Items Needed

Before installing fireplace, make sure you have the items listed below.

external regulator for propane/LP unit only (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap (optional)

tee joint

pipe wrench

approved flexible gas line with gas connector (if allowed by local codes) (not provided)

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 31.

For propane/LP units, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pres- sure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 13. Pointing the vent down protects it from freezing rain or sleet.

Propane/LP

Supply Tank

External

Regulator

Vent

Pointing

Down

Figure 13 - External Regulator With Vent Pointing Down

CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to fireplace. If pipe is too small, undue loss of volume will occur.

Installation must include an equipment shutoff valve, union and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 14).

IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.

Check your building codes for any special re- quirements for locating equipment shutoff valve to fireplaces.

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves. Never use sealant on flare threads.

CSA Design-Certified

Equipment Shutoff Valve

With 1/8" NPT Tap*

 

Natural Gas

 

From Gas Meter

 

(5" W.C.** to 10.5"

 

W.C. Pressure)

 

Propane/LP

 

From External

 

Regulator

 

(11" W.C.** to 14"

3" Minimum

W.C. Pressure)

 

 

Cap

Pipe

Tee

Sediment

Nipple

Joint

Trap

 

 

Figure 14 - Gas Connection

*Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 31.

** Minimum inlet pressure for purpose of input adjustment.

14

www.desatech.com

113192-01B

Image 14
Contents What to do if YOU Smell GAS Models VSGF36NT, VSGF36PT, VSGF36NR and VSGF36PRTable of Contents Safety Information Local Codes Unpacking Product FeaturesProduct Identification Planning Product SpecificationsLocating Firebox Unusually Tight Construction AIR for Combustion VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation Air From Inside Building InstallationVentilation AIR Ventilation Air From OutdoorsInstallation Clearances Minimum Wall and Ceiling Clearances see FigureBUILT-IN Firebox Installation Mantel Clearances for Built-In InstallationRough Opening Dimensions for Built-in Installation Installing Firebox Using Optional Accessory Mantels Installing GAS Piping to Fireplace LocationPropane/LP Installation Items NeededNatural Gas Connecting Fireplace to GAS Supply Removing Log Base Assembly From FireplaceTest Pressures In Excess Of 1/2 Psig Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections KPaGroove HARD-WIRING Firebox Installing Fireplace Hood and ScreenLighting Instructions Thermostat Models For Your Safety Read Before LightingOperating Fireplace To Turn OFF GAS To Appliance Manual Lighting ProcedureRemote Control Models For Your Safety Read Before Lighting Thermostat Control OperationSet flame adjustment knob to any level between HI and LO Shutting Off Heater Blower OperationOptional HAND-HELD Remote Operation Auto Shutoff Feature Manual ModeAuto Thermostatic Mode ON/OFF Series Model GhrcbPilot Flame Pattern Key Pad Lock FeatureInspecting Burners Main BurnerCleaning Maintenance Burner Injector Holder and Pilot AIR Inlet HoleTechnical Service Wiring Diagram Replacement PartsSpecifications Service HintsTroubleshooting Observed Problem Possible Cause RemedyDiagram, See Cleaning and Mainte Shut off gas supply Do not try to light any appliance Accessories Illustrated Parts Breakdown Models VSGF36PT, VSGF36NTParts List Models VSGF36PR, VSGF36NR KEY Part Number VSGF36PR VSGF36NR Description QTY Models VSGF36PT, VSGF36NT, VSGF36PR and VSGF36NR KEY Part Number Description QTY 113192-01B 113192-01B Limited Warranty VENT-FREE GAS Fireplace Warranty InformationKeep this Warranty

VSGF36PR, VSGF36NR, VSGF36PT, VSGF36NT specifications

The Desa VSGF36NR, VSGF36PT, VSGF36PR, and VSGF36NT are remarkable fireplace solutions that cater to diverse heating needs and aesthetic preferences. Each model is designed to enhance the ambiance of any space while providing efficient warmth.

One of the standout features of these gas fireplaces is their efficiency. They are engineered to provide superior heat output while minimizing gas consumption, making them both eco-friendly and economical. Each unit is equipped with advanced modulation technologies that adjust the flame height based on the room temperature, ensuring optimal heating without wasting fuel.

In terms of design, the Desa models boast a sleek and contemporary aesthetic. The VSGF36NR features a traditional linear design that meshes well with modern interiors. Its large viewing window offers an unobstructed view of the flames, creating a cozy environment. Conversely, the VSGF36PT and VSGF36PR models are designed with a more classical touch, integrating ornate details that enhance the beauty of any room while still maintaining modern functionality.

A key characteristic of these fireplaces is the ease of installation. They come pre-assembled with straightforward installation instructions, allowing homeowners to set them up quickly and conveniently. Additionally, each model can be configured for either vented or vent-free operation, providing versatility based on individual preferences and home requirements.

Convenience is further amplified by remote control options, allowing users to operate the fireplace from the comfort of their seat. The user-friendly interface enables easy temperature adjustments and flame settings. Safety features have also been prioritized; built-in oxygen depletion sensors ensure that the air quality in the room remains safe while the fireplace is in operation.

Another critical aspect of the VSGF series is their ability to integrate seamlessly with smart home technologies. Homeowners can connect their fireplaces to Wi-Fi, allowing for remote monitoring and control via smartphone applications. This ensures that heating can be adjusted from anywhere, adding a layer of modern convenience.

In conclusion, the Desa VSGF36NR, VSGF36PT, VSGF36PR, and VSGF36NT models are not just fireplaces; they are efficient, stylish heating solutions equipped with advanced technology designed for comfort, safety, and convenience. With their blend of design and functionality, these models are an excellent choice for anyone looking to enhance their living space with the warmth and charm of a gas fireplace.