Desa VSGF36PR Blower Operation, Optional HAND-HELD Remote Operation, Shutting Off Heater

Page 22

OPERATING FIREPLACE

Continued

BLOWER OPERATION

WARNING: Make sure the se- lectorswitchisintheOFFposition whenyouareawayfromhomefor long periods of time. Heater will comeonautomaticallywithselec- tor switch in the ON position.

Pilot

Ignitor

Pilot

Ignitor

Burner

Electrode

Electrode

Burner

 

 

Figure 29 - Pilot

Figure 30 - Pilot

(Natural)

(Propane/LP)

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise to the OFF position.

2a.

Set selector switch in the OFF position.

2b.

If Using Optional Hand-Held Remote: Set

 

selector switch in the OFF position to keep

 

from draining battery.

Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pilot

lit by doing one of the following:

Turn control knob clockwise to the PILOT position.

Use remote control manual OFF button.

Set selector switch in the OFF position.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 6 under Lighting Instructions, page 21.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 11 under Lighting Instructions, page 21.

WARNING: This fireplace has athree-prong,groundedelectrical plug. This plug helps protect you againstelectricalshock.Onlycon- nect plug to a properly grounded, three-prongreceptacle.Donotcut or remove the grounding prong from this plug.

Locate the blower switch by opening lower louver on fireplace. Blower switch is located at lower left inside louver door. This thermostat-controlled blower has a vari- able speed control with an ON/OFF switch. The blower will start when the thermostat senses a sufficient increase in firebox temperature. Note: It is safe to operate fireplace with blower turned off. However, the blower helps distribute heated air from the fireplace. Note: Periodically check the louvers of the firebox and remove any dust, dirt or other obstructions.

OPTIONAL HAND-HELD

REMOTE OPERATION

Note: All remote control accessories must be purchased separately (see Accessories, pages 31). Follow instructions included with the re- mote control.

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions on page 21.

After lighting, let pilot flame burn for about one minute. Turn control knob to ON posi- tion. Adjust flame adjustment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position (see Figure 31, page 23). Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit. IMPORTANT: Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery.

22

www.desatech.com

113192-01B

Image 22
Contents What to do if YOU Smell GAS Models VSGF36NT, VSGF36PT, VSGF36NR and VSGF36PRTable of Contents Safety Information Local Codes Product Identification Product FeaturesUnpacking Locating Firebox Product SpecificationsPlanning Unusually Tight Construction AIR for Combustion VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation Air From Inside Building InstallationVentilation AIR Ventilation Air From OutdoorsInstallation Clearances Minimum Wall and Ceiling Clearances see FigureBUILT-IN Firebox Installation Mantel Clearances for Built-In InstallationRough Opening Dimensions for Built-in Installation Installing Firebox Using Optional Accessory Mantels Installing GAS Piping to Fireplace LocationNatural Gas Installation Items NeededPropane/LP Connecting Fireplace to GAS Supply Removing Log Base Assembly From FireplaceTest Pressures In Excess Of 1/2 Psig Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections KPaGroove HARD-WIRING Firebox Installing Fireplace Hood and ScreenOperating Fireplace Thermostat Models For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureRemote Control Models For Your Safety Read Before Lighting Thermostat Control OperationSet flame adjustment knob to any level between HI and LO Optional HAND-HELD Remote Operation Blower OperationShutting Off Heater Auto Shutoff Feature Manual ModeAuto Thermostatic Mode ON/OFF Series Model GhrcbPilot Flame Pattern Key Pad Lock FeatureInspecting Burners Main BurnerCleaning Maintenance Burner Injector Holder and Pilot AIR Inlet HoleTechnical Service Wiring Diagram Replacement PartsSpecifications Service HintsTroubleshooting Observed Problem Possible Cause RemedyDiagram, See Cleaning and Mainte Shut off gas supply Do not try to light any appliance Accessories Illustrated Parts Breakdown Models VSGF36PT, VSGF36NTParts List Models VSGF36PR, VSGF36NR KEY Part Number VSGF36PR VSGF36NR Description QTY Models VSGF36PT, VSGF36NT, VSGF36PR and VSGF36NR KEY Part Number Description QTY 113192-01B 113192-01B Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS Fireplace

VSGF36PR, VSGF36NR, VSGF36PT, VSGF36NT specifications

The Desa VSGF36NR, VSGF36PT, VSGF36PR, and VSGF36NT are remarkable fireplace solutions that cater to diverse heating needs and aesthetic preferences. Each model is designed to enhance the ambiance of any space while providing efficient warmth.

One of the standout features of these gas fireplaces is their efficiency. They are engineered to provide superior heat output while minimizing gas consumption, making them both eco-friendly and economical. Each unit is equipped with advanced modulation technologies that adjust the flame height based on the room temperature, ensuring optimal heating without wasting fuel.

In terms of design, the Desa models boast a sleek and contemporary aesthetic. The VSGF36NR features a traditional linear design that meshes well with modern interiors. Its large viewing window offers an unobstructed view of the flames, creating a cozy environment. Conversely, the VSGF36PT and VSGF36PR models are designed with a more classical touch, integrating ornate details that enhance the beauty of any room while still maintaining modern functionality.

A key characteristic of these fireplaces is the ease of installation. They come pre-assembled with straightforward installation instructions, allowing homeowners to set them up quickly and conveniently. Additionally, each model can be configured for either vented or vent-free operation, providing versatility based on individual preferences and home requirements.

Convenience is further amplified by remote control options, allowing users to operate the fireplace from the comfort of their seat. The user-friendly interface enables easy temperature adjustments and flame settings. Safety features have also been prioritized; built-in oxygen depletion sensors ensure that the air quality in the room remains safe while the fireplace is in operation.

Another critical aspect of the VSGF series is their ability to integrate seamlessly with smart home technologies. Homeowners can connect their fireplaces to Wi-Fi, allowing for remote monitoring and control via smartphone applications. This ensures that heating can be adjusted from anywhere, adding a layer of modern convenience.

In conclusion, the Desa VSGF36NR, VSGF36PT, VSGF36PR, and VSGF36NT models are not just fireplaces; they are efficient, stylish heating solutions equipped with advanced technology designed for comfort, safety, and convenience. With their blend of design and functionality, these models are an excellent choice for anyone looking to enhance their living space with the warmth and charm of a gas fireplace.