Desa VSGF36PT, VSGF36NT Cleaning Maintenance, Burner Injector Holder and Pilot AIR Inlet Hole

Page 25

CLEANING AND

MAINTENANCE

WARNING: Turn off fireplace and let cool before cleaning.

CAUTION: You must keep control areas, burner and cir- culating air passageways of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.

WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting and property damage.

BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the directions on the can. If you donʼt follow directions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot and primary air inlet holes on injector holder for dust and dirt (see Figure 38).

3.Blow air through the ports/slots and holes in the burner.

4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint or pet hair with a soft cloth or vacuum cleaner nozzle.

5.Blow air into the primary air holes on the injector holder.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot as- sembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 39). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

 

Injector

Ports/

Holder

 

Slots

 

Burner

Tube

Primary Air

Inlet Holes

Figure 38 - Injector Holder On Outlet

Burner Tube

Ports/Slots

Burner

Tube

Pilot

Assembly

Pilot Air

Inlet Hole

Figure 39 - Pilot Inlet Air Hole

113192-01B

www.desatech.com

25

Image 25
Contents Models VSGF36NT, VSGF36PT, VSGF36NR and VSGF36PR What to do if YOU Smell GASTable of Contents Safety Information Local Codes Product Identification Product FeaturesUnpacking Locating Firebox Product SpecificationsPlanning Providing Adequate Ventilation AIR for Combustion VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation AIR InstallationVentilation Air From Inside Building Ventilation Air From OutdoorsMinimum Wall and Ceiling Clearances see Figure Installation ClearancesMantel Clearances for Built-In Installation BUILT-IN Firebox InstallationRough Opening Dimensions for Built-in Installation Installing GAS Piping to Fireplace Location Installing Firebox Using Optional Accessory MantelsNatural Gas Installation Items NeededPropane/LP Removing Log Base Assembly From Fireplace Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing Fireplace Gas ConnectionsTest Pressures In Excess Of 1/2 Psig KPaGroove Installing Fireplace Hood and Screen HARD-WIRING FireboxOperating Fireplace Thermostat Models For Your Safety Read Before LightingLighting Instructions Remote Control Models For Your Safety Read Before Lighting Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationSet flame adjustment knob to any level between HI and LO Optional HAND-HELD Remote Operation Blower OperationShutting Off Heater Auto Thermostatic Mode Manual ModeAuto Shutoff Feature ON/OFF Series Model GhrcbInspecting Burners Key Pad Lock FeaturePilot Flame Pattern Main BurnerBurner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceSpecifications Wiring Diagram Replacement PartsTechnical Service Service HintsObserved Problem Possible Cause Remedy TroubleshootingDiagram, See Cleaning and Mainte Shut off gas supply Do not try to light any appliance Accessories Models VSGF36PT, VSGF36NT Illustrated Parts BreakdownParts List Models VSGF36PR, VSGF36NR KEY Part Number VSGF36PR VSGF36NR Description QTY Models VSGF36PT, VSGF36NT, VSGF36PR and VSGF36NR KEY Part Number Description QTY 113192-01B 113192-01B Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS Fireplace

VSGF36PR, VSGF36NR, VSGF36PT, VSGF36NT specifications

The Desa VSGF36NR, VSGF36PT, VSGF36PR, and VSGF36NT are remarkable fireplace solutions that cater to diverse heating needs and aesthetic preferences. Each model is designed to enhance the ambiance of any space while providing efficient warmth.

One of the standout features of these gas fireplaces is their efficiency. They are engineered to provide superior heat output while minimizing gas consumption, making them both eco-friendly and economical. Each unit is equipped with advanced modulation technologies that adjust the flame height based on the room temperature, ensuring optimal heating without wasting fuel.

In terms of design, the Desa models boast a sleek and contemporary aesthetic. The VSGF36NR features a traditional linear design that meshes well with modern interiors. Its large viewing window offers an unobstructed view of the flames, creating a cozy environment. Conversely, the VSGF36PT and VSGF36PR models are designed with a more classical touch, integrating ornate details that enhance the beauty of any room while still maintaining modern functionality.

A key characteristic of these fireplaces is the ease of installation. They come pre-assembled with straightforward installation instructions, allowing homeowners to set them up quickly and conveniently. Additionally, each model can be configured for either vented or vent-free operation, providing versatility based on individual preferences and home requirements.

Convenience is further amplified by remote control options, allowing users to operate the fireplace from the comfort of their seat. The user-friendly interface enables easy temperature adjustments and flame settings. Safety features have also been prioritized; built-in oxygen depletion sensors ensure that the air quality in the room remains safe while the fireplace is in operation.

Another critical aspect of the VSGF series is their ability to integrate seamlessly with smart home technologies. Homeowners can connect their fireplaces to Wi-Fi, allowing for remote monitoring and control via smartphone applications. This ensures that heating can be adjusted from anywhere, adding a layer of modern convenience.

In conclusion, the Desa VSGF36NR, VSGF36PT, VSGF36PR, and VSGF36NT models are not just fireplaces; they are efficient, stylish heating solutions equipped with advanced technology designed for comfort, safety, and convenience. With their blend of design and functionality, these models are an excellent choice for anyone looking to enhance their living space with the warmth and charm of a gas fireplace.